ASTM D1583-2001 Standard Test Method for Hydrogen Ion Concentration of Dry Adhesive Films《干粘膜中氢离子浓度的标准试验方法》.pdf
《ASTM D1583-2001 Standard Test Method for Hydrogen Ion Concentration of Dry Adhesive Films《干粘膜中氢离子浓度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1583-2001 Standard Test Method for Hydrogen Ion Concentration of Dry Adhesive Films《干粘膜中氢离子浓度的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1583 01Standard Test Method forHydrogen Ion Concentration of Dry Adhesive Films1This standard is issued under the fixed designation D 1583; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers determination of the hydroge
3、nion concentration (pH), acidity, or alkalinity, of organic adhe-sives in the cured dry film form. This test method is notdesigned to apply to pressure-sensitive adhesives.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3
4、 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Docu
5、ments2.1 ASTM Standards:D 907 Terminology of Adhesives2E 70 Test Method for pH of Aqueous Solutions With theGlass Electrode33. Terminology3.1 Definitions Many of the terms in this test method aredefined in Terminology D 907.4. Summary of Test Method4.1 Collect samples of the adhesive to be tested wi
6、th anyhardener necessary.4.2 Dry adhesive films are prepared.4.3 The adhesive films are ground and mixed with distilledwater.4.4 The pH is determined using a pH meter in accordancewith Test Method E 70.5. Significance and Use5.1 The pH of an adhesive may be a factor whereby theadherends or the adhes
7、ive itself may be adversely affected intime by the acidity or alkalinity.6. Apparatus6.1 pH Meter, capable of making measurements to 60.05pH.6.2 Glass Vial, capable of properly immersing the electrodeof the pH meter when filled with the specified test solution.6.3 Distilled Water, with a pH between
8、5.6 and 7.0 at 23 61C (73.4 6 1.8F).6.4 Glass Sheet, free from scratches, approximately 200 by250 mm (8 by 10 in.) in size for use in oven.6.5 Circulating-Air Oven, capable of maintaining tempera-tures of 23 6 1C (73.4 6 1.8F) to 150 6 1C (302 6 1.8F).7. Sampling7.1 Except in special cases, take a c
9、omposite sample whenpossible from three or more separate containers, chosen atrandom. Also take samples from containers which appear to benonrepresentative, and test such samples separately. Place thesamples immediately in airtight glass containers filled toprevent excessive air space above the adhe
10、sive and transportthem to the testing laboratory in these containers. Takeprecautions to reduce evaporation or drying to a minimum.Thoroughly mix the adhesive in the container if there is atendency for the materials to separate before a sample is taken.Use the required catalysts and hardeners from t
11、he sameshipment as the other adhesive components if the componentsare furnished as a unit by the adhesive manufacturer.8. Test Specimens8.1 Room-Temperature Setting AdhesivesUse adhesivesthat form dry films at room temperature and mix in accordancewith the recommendations of the adhesive manufacture
12、r.Spread the adhesive on glass or other inert material to whichthe adhesive does not adhere to a film thickness of less than0.51 mm (0.020 in.) and allow it to dry at 23 6 1C (73.4 61.8F).8.2 Elevated-Temperature Setting AdhesivesMix adhe-sives that require heat to form a dry film in accordance with
13、 therecommendations of the manufacturer. Prepare a film of theadhesive on glass or other inert material to which the adhesivedoes not adhere, and cure it in accordance with the recommen-dations of the manufacturer. The adhesive film should be lessthan 0.51 mm (0.020 in.) in thickness. In the absence
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD15832001STANDARDTESTMETHODFORHYDROGENIONCONCENTRATIONOFDRYADHESIVEFILMS 粘膜 氢离子 浓度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510092.html