ASTM D1280-2000(2007) Standard Guide for Total Immersion Corrosion Test for Soak Tank Metal Cleaners《浸槽式金属除垢剂的全浸腐蚀试验的标准指南》.pdf
《ASTM D1280-2000(2007) Standard Guide for Total Immersion Corrosion Test for Soak Tank Metal Cleaners《浸槽式金属除垢剂的全浸腐蚀试验的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1280-2000(2007) Standard Guide for Total Immersion Corrosion Test for Soak Tank Metal Cleaners《浸槽式金属除垢剂的全浸腐蚀试验的标准指南》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1280 00 (Reapproved 2007)Standard Guide forTotal Immersion Corrosion Test for Soak Tank MetalCleaners1This standard is issued under the fixed designation D 1280; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers determination of the corrosive effectsof soak tank metal cleaners on all metals other than al
3、uminumand its alloys, under conditions of total immersion, by quanti-tative measurement of weight change or by qualitative visualdetermination of change. The test determines the effects of thecleaner on metals being cleaned, and does not determine thelife of the cleaner or of the containing equipmen
4、t.1.2 When the test is used to assist in the choice of materialfor a specific use, the test conditions should simulate theconditions of use as closely as practicable.1.3 Where no further processing subsequent to cleaning isindicated, a test for the effect of residual cleaner on thecorrosion behavior
5、 of the material may be required.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitat
6、ions prior to use. Material SafetyData Sheets are available for reagents and materials. Reviewthem for hazards prior to usage.2. Referenced Documents2.1 ASTM Standards:2D 930 Test Method of Total Immersion Corrosion Test ofWater-Soluble Aluminum Cleaners (Discontinued 2001)33. Significance and Use3.
7、1 This guide is used to distinguish soak tank metalcleaners that are excessively corrosive to metals (other thanaluminum and its alloys which are covered by Method D 930).The users will define the degree of corrosion consideredexcessive, in terms of weight loss per unit of surface area or interms of
8、 changes in appearance, or both.4. Apparatus4.1 Test Tubes, of a suitable material 38 mm in diameter by300 mm in length, having a capacity of about 300 mL. Thetubes shall be chosen so that the specimens will remain fullyimmersed during the test, and the ratio of area of immersedmetal to the volume o
9、f solution will be prescribed in 7.1, withsufficient space provided for foam formation.4.2 Condensers, Allihn-type, having jackets 200 to 250 mmin length, except that condensers will not be required for testsrun at room temperature.4.3 Stoppers or JointsThe connection between test tubeand condenser
10、optionally may be either standard-taper joints orrubber stoppers preboiled in aqueous caustic soda to removefree sulfur, and boiled in a sufficient number of changes ofdistilled water until neutral.4.4 Constant-Temperature DeviceAny suitable meansmay be employed for maintaining the solutions activel
11、y at theboiling point for tests conducted at that temperature. For testsmade at other temperatures, a suitable constant-temperaturebath shall be provided to maintain the required temperaturewithin 62F (1C). For control testing at room temperature, itis suggested that the solution be maintained at 95
12、 6 2F (35 61C), which, being slightly above most room temperatures, iseasy to maintain by heat input.4.5 Coating Apparatus, shall be provided suitable for pro-ducing a uniform film of cleaner on the surface of the testspecimen, for testing the effects of residual cleaner on thesurfaces of cleaned me
13、tals (Section 10).4.6 Humidity Chamber, for exposing the contaminatedspecimens at 90 % relative humidity as specified in 10.1.3.5. Test Specimens5.1 The test specimens shall be identical in composition,metallurgy, and surface finishing, with the conditions of themetal at the stage where cleaning wil
14、l be applied in practice.The specimens shall have an area between 0.300 and 0.375dm2, and a length not to exceed 200 mm. (A specimen 18 by85 by 1 mm in thickness would have an area of 0.327 dm2.) Atleast two, and preferably four, replicates shall be tested in each1This guide is under the jurisdictio
15、n of ASTM Committee D12 on Soaps andOther Detergents and is the direct responsibility of Subcommittee D12.16 on HardSurface Cleaning.Current edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1953. Last previous edition approved in 2000 as D 1280 00.2For referenced ASTM sta
16、ndards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Co
17、nshohocken, PA 19428-2959, United States.concentration of cleaner solution prescribed in 7.2. The numberof replicates under test shall be recorded.6. Precleaning Test Specimens6.1 Make ready the following pre-cleaning materials forremoval of soil present on the metal surface prior to corrosiontestin
18、g:6.1.1 Place 200 mL of trichloroethylene in a 250-mL beakerand maintain at room temperature.6.1.2 Prepare a vapor degreasing bath by heating 150 to 200mL of trichloroethylene in a 1-L beaker, the degree ofvaporization being controlled to permit vapor degreasing of thespecimens when held in the beak
19、er; or, alternatively, fill a washbottle containing either of these solvents at room temperature.6.1.3 Maintain a 250-mL beaker of either anhydrous metha-nol or isopropanol at 122F (50C).6.1.4 Maintain a 250-mL beaker of distilled water at 122F(50C).6.1.5 Maintain a 250-mL beaker of redistilled acet
20、one atroom temperature.6.1.6 Place a small swab of fresh absorbent cotton in each ofthe beakers (6.1.1-6.1.5).6.2 Immediately prior to their use in the test, clean the testspecimens as follows:6.2.1 Immerse the test specimens in the beaker of trichlo-roethylene (6.1.1) and immediately swab the surfa
21、ces of theindividual specimens thoroughly, using clean forceps to holdboth the cotton swab and the test specimen.6.2.2 Shake off excess solvent and either transfer the speci-men to the vapor degreasing bath (6.1.2) long enough toobserve the vapor completely covering and condensing on thespecimen, or
22、 thoroughly wash the specimen with a stream offresh solvent from the wash bottle.6.2.3 Swab the specimens separately in the beaker ofalcohol (6.1.3) and shake free from excess alcohol.6.2.4 Transfer the specimens to the beaker of distilled water(6.1.4). Swab carefully and shake free from excess wate
23、r.6.2.5 Immerse the specimens separately several times in thebeaker of acetone (6.1.5), and shake free from acetone.6.2.6 If the specimens are to be weighed, dry in a vacuumdesiccator or in a low-temperature oven at 100F (37.7C).7. Test Conditions7.1 Ratio of Area of Immersed Metal to Volume ofSolut
24、ionThe ratio of the area of the immersed metal to thevolume of solution shall be less than 1.5 dm2/L of solution. (Aspecimen 18 by 85 by 1 mm in thickness would require 220 mLof solution, and a specimen having an area of 0.375 dm2wouldrequire 250 mL of solution.) Use fresh solution for each set ofre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD128020002007STANDARDGUIDEFORTOTALIMMERSIONCORROSIONTESTFORSOAKTANKMETALCLEANERS 浸槽式 金属 除垢剂 腐蚀 试验

链接地址:http://www.mydoc123.com/p-509566.html