ASTM D1084-2008 Standard Test Methods for Viscosity of Adhesives《胶粘剂粘度的标准试验方法》.pdf
《ASTM D1084-2008 Standard Test Methods for Viscosity of Adhesives《胶粘剂粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1084-2008 Standard Test Methods for Viscosity of Adhesives《胶粘剂粘度的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1084 08Standard Test Methods forViscosity of Adhesives1This standard is issued under the fixed designation D 1084; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses in
2、dicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense. These test methods replace Method 4021 or FederalTest Method Standard No. 175a.1. Scope1
3、.1 These test methods cover the determination of theviscosity of free-flowing adhesives.1.1.1 The limitation of this test method to self-levelingadhesives eliminates thixotropic and plastic materials whoseviscosity is a function of the rate of stirring and previoushistory of the adhesive.1.2 The val
4、ues stated in SI units are to be regarded as thestandard. The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
5、 and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D88 Test Method for Saybolt ViscosityD115 Test Methods for Testing Solvent Containing Var-nishes Used for Electrical InsulationD 562 Test Method for Consistency of
6、 Paints MeasuringKrebs Unit (KU) Viscosity Using a Stormer-Type Viscom-eterD 907 Terminology of AdhesivesD 1200 Test Method for Viscosity by Ford Viscosity CupD 1545 Test Method for Viscosity of Transparent Liquidsby Bubble Time MethodD 1601 Test Method for Dilute Solution Viscosity of Eth-ylene Pol
7、ymersD 2556 Test Method for Apparent Viscosity of AdhesivesHaving Shear-Rate-Dependent Flow Properties2.2 ISO Document:3ISO 2555 Plastics Resins in the Liquid State or asEmulsions or Dispersions Determination of ApparentViscosity by the Brookfield Test Method3. Terminology3.1 DefinitionsMany terms i
8、n these test methods aredefined in Terminology D 907.3.1.1 viscosity, nof a liquid, the resistance to flow ex-pressed as the ratio of the applied stress to the resulting rate ofshearing strain (see Newtonian behavior and thixotropy).(Compare consistency.)3.2 Definitions of Terms Specific to This Sta
9、ndard:3.2.1 viscosity, nthe ratio of shear stress to shear rate. Theviscosity of a liquid is a measure of the internal friction of theliquid in motion. The unit of dynamic viscosity is the poise,which is expressed as dyne-seconds per square centimetre. Fora Newtonian liquid, the viscosity is constan
10、t at all shear rates.For a non-Newtonian liquid, viscosity will vary depending onshear rate.4. Significance and Use4.1 Several test methods are noted for viscosity determina-tion of Newtonian and near Newtonian flow characteristics.(For adhesives not fitting into this category, Test MethodD 2556 sho
11、uld be considered.) Four test methods are coveredas follows:4.1.1 Method A is applicable only to adhesives that willdeliver 50 mL in a steady uninterrupted stream from one of thecups described in Section 5.4.1.2 Method B is intended for measuring the viscosity ofadhesives covering a range from 0.05
12、Pasto200Pas(50 to 200 000 cP) and is limited to materials that have orapproach Newtonian flow characteristics.4.1.3 Method C is intended primarily as a control methodfor determining the viscosity of adhesives that have or ap-proach Newtonian flow characteristics.1These test methods are under the jur
13、isdiction of ASTM Committee D14 onAdhesives and are the direct responsibility of Subcommittee D14.10 on WorkingProperties.Current edition approved Feb. 1, 2008. Published February 2008. Originallyapproved in 1950. Last previous edition approved in 2005 as D 1084 97 (2005).2For referenced ASTM standa
14、rds, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor,
15、New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.4 Method D is intended primarily as a control methodfor determining the viscosity of materials that have an equiva-lent viscosity no greater t
16、han approximately 3000 cP and islimited to materials that have or approach Newtonian flowcharacteristics.TEST METHOD A5. Apparatus5.1 The apparatus (Fig. 1) consists of a set of four viscositycups so designed as to deliver 50 mL of the sample in from 30to 100 s at a temperature of 23 6 0.5C (73.4 6
17、0.9F).5.1.1 Four consistency cups constitute a set as follows:Diameter of Orifice, in.First Cup 0.07 6 0.0001Second cup 0.10 6 0.0001Third cup 0.15 6 0.0001Fourth cup 0.25 6 0.00015.1.2 Cups made of brass or bronze. Orifice disks made of18 % Chromium, 8 % Nickel stainless steel. The diameter ofthe O
18、rifice pressed in the cup shall be stamped on the cup5.1.3 Fractional dimensions subject to permissible varia-tions of 60.01 in., unless otherwise specified.6. Procedure6.1 Bring the sample to be tested and the viscosity cup to atemperature of 23 6 0.5C (73.4 6 0.9F) (preferably in aconstant-tempera
19、ture room). Then mount the consistency cupin the clamp provided for the purpose and place the receivingcylinder in position. With the outlet of the cup closed by meansof the finger, pour the sample into the cup until it is filled tooverflowing. Strike off the excess with a straightedge, and thenremo
20、ve the finger from over the outlet and allow the sample toflow into the receiving cylinder. Determine the number ofseconds from the time the finger is removed from the orificeuntil the top of the meniscus reaches to 50-mL mark on thecylinder by a stop watch and record as the viscosity of thematerial
21、.7. Report7.1 Report the following:7.1.1 Complete identification of the adhesive tested, includ-ing type, source, manufacturers code numbers, form, date oftest, date of manufacture, etc.,7.1.2 Conditioning procedure used for samples prior totesting,7.1.3 Number of tests made, and7.1.4 Average consis
22、tency in seconds and the number of theviscosity cup used.TEST METHOD B8. Procedure8.1 Refer to ISO 2555 for this test method.TEST METHOD C9. Apparatus9.1 ViscometerA Stormer viscosimeter with double flagpaddle-type rotor as specified in Test Method D 562,oranAll dimensions are in mmFIG. 1 Consistenc
23、y Cups and Apparatus Assembly(Test Method A)D1084082equivalent apparatus, in good repair and a spindle that spinsfreely when started without the paddle.9.2 ContainersRound friction-top metal cans having acapacity of 1 qt (0.9 L). Nonstandard containers may be usedby mutual agreement, when necessary
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD10842008STANDARDTESTMETHODSFORVISCOSITYOFADHESIVES 胶粘剂 粘度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509244.html