1、Designation: D 1048 05Standard Specification forRubber Insulating Blankets1This standard is issued under the fixed designation D 1048; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthes
2、es indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers acceptance testing of rubberinsulating blanket
3、s for protection of workers from accidentalcontact with live electrical conductors, apparatus, or circuits.1.2 Two types of blankets are provided and are designatedas Type I, not resistant to ozone, and Type II, resistant to ozone.1.3 Five classes of blankets, differing in electrical charac-teristic
4、s, are provided and are designated as Class 0, Class 1,Class 2, Class 3, and Class 4.1.4 Two styles of blankets, differing in construction charac-teristics, are provided and are designated as Style A and StyleB.1.5 The following safety hazards caveat pertains only to thetest method portion, Sections
5、 16-19, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prio
6、r to use.2. Referenced Documents2.1 ASTM Standards:2D 149 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD 297 Test Methods for Rubber ProductsChemicalAnalysisD 412 Test Methods for Vulcanized Rubber and Ther
7、mo-plastic Rubbers and Thermoplastic ElastomersTensionD 518 Test Method for Rubber DeteriorationSurfaceCrackingD 570 Test Method for Water Absorption of PlasticsD 573 Test Method for RubberDeterioration in an AirOvenD 624 Test Method for Tear Strength of ConventionalVulcanized Rubber and Thermoplast
8、ic ElastomersD 1388 Test Methods for Stiffness of FabricsD 2865 Practice for Calibration of Standards and Equip-ment for Electrical Insulating Materials TestingF 819 Terminology Relating to Electrical Protective Equip-ment for Workers2.2 American National Standards:C 2 National Electrical Safety Cod
9、e, Section 443C39.5 Safety Requirements for Electrical and ElectronicMeasuring and Controlling Instrumentation3C84.1 Voltage Ratings for Electric Power Systems andEquipment (60 Hz)33. Terminology3.1 beaded edge a narrow border of thicker rubber whichextends completely around the outer edges of the b
10、lanket.3.2 breakdownthe electrical discharge or arc occurringbetween the electrodes and through the equipment being tested.3.3 designated personan individual who is qualified byexperience or training to perform an assigned task.3.4 electrical testing facilitya location with qualified per-sonnel, tes
11、ting equipment, and procedures for the inspectionand electrical testing of electrical insulating protective equip-ment.3.5 electrode clearancethe shortest path from the ener-gized electrode to the ground electrode.3.6 flashoverthe electrical discharge or arc occurringbetween electrodes and over or a
12、round, but not through, theequipment being tested.3.7 insulatedseparated from other conducting surfaces bya dielectric substance (including air space) offering a highresistance to the passage of current.3.7.1 DiscussionWhen any object is said to be insulated,it is understood to be insulated in a sui
13、table manner for theconditions to which it is subjected. Otherwise, it is, within thepurpose of this definition, uninsulated. Insulating covering ofconductors is one means of making this conductor insulated.1This specification is under the jurisdiction of ASTM Committee F18 onElectrical Protective E
14、quipment for Workers and is the direct responsibility ofSubcommittee F18.25 on Insulating Cover-up Equipment. This standard replacesANSI Standard J 6.4, which is no longer available.Current edition approved Feb. 1, 2005. Published March 2005. Originallyapproved in 1949 as D 1048 49 T. Last previous
15、edition approved in 1999 asD 1048 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available fromAmerican
16、National Standards Institute, 25 West 43rd Street, 4thFloor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.8 ozonea very active form of oxygen that may beproduced by corona, arcing, or ultra-violet rays.3.9 ozo
17、ne cutting and checkingcracks produced by ozonein a material under mechanical stress.3.10 rubbera generic term that includes elastomers andelastomer compounds regardless of origin.3.11 userthe employer or entity purchasing the equipmentto be utilized by workers for their protection; in the absence o
18、fsuch an employer or entity, the individual purchasing orutilizing the protective equipment.3.12 voltage, maximum retestvoltage, either ac rms or dcavg, that is equal to the proof-test voltage for new protectiveequipment.3.13 voltage, retestvoltage, either ac rms or dc avg, thatused protective equip
19、ment must be capable of withstanding fora specified test period without breakdown.3.14 voltage, nominal designa nominal value consistentwith the latest revision of ANSI C84.1, assigned to the circuitor system for the purpose of conveniently designating itsvoltage class.3.15 voltage, maximum usethe a
20、c voltage, (rms), classi-fication of the protective equipment that designates the maxi-mum nominal design voltage of the energized system that maybe safely worked. The nominal design voltage is equal tophase-to-phase voltage on multiphase circuits.3.15.1 If there is no multiphase exposure in a syste
21、m area,and the voltage exposure is limited to phase (polarity on dcsystems) to ground potential, the phase (polarity on dc sys-tems) to ground potential shall be considered to be the nominaldesign voltage.3.15.2 If electrical equipment and devices are insulated orisolated, or both, such that the mul
22、itphase exposure on agrounded wye circuit is removed, then the nominal designvoltage may be considered as the phase-to-ground voltage onthat circuit.NOTE 1The work practices and methods associated with removingmultiphase exposures at any given work site are not addressed in thisspecification. Users
23、should refer to ANSI C2, National Electrical SafetyCode, Section 44, for proper work practices.3.16 For definitions of other terms, refer to TerminologyF 819.4. Significance and Use4.1 This specification covers the minimum electrical,chemical, and physical properties guaranteed by the manufac-turer
24、and the detailed procedures by which such properties areto be determined. The purchaser may, at his option, perform orhave performed any of these tests in order to verify theguarantee. Claims for failure to meet the specification aresubject to verification by the manufacturer.4.2 Blankets are used f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD10482005STANDARDSPECIFICATIONFORRUBBERINSULATINGBLANKETS 橡胶 绝缘 标准规范 PDF

链接地址:http://www.mydoc123.com/p-509165.html