ASTM C953-2006 Standard Test Method for Time of Setting of Grouts for Preplaced-Aggregate Concrete in the Laboratory《实验室内测定预置集料混凝土的灌浆料凝固时间的标准试验方法》.pdf
《ASTM C953-2006 Standard Test Method for Time of Setting of Grouts for Preplaced-Aggregate Concrete in the Laboratory《实验室内测定预置集料混凝土的灌浆料凝固时间的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C953-2006 Standard Test Method for Time of Setting of Grouts for Preplaced-Aggregate Concrete in the Laboratory《实验室内测定预置集料混凝土的灌浆料凝固时间的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 953 06Standard Test Method forTime of Setting of Grouts for Preplaced-Aggregate Concretein the Laboratory1This standard is issued under the fixed designation C 953; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This method covers the determination test of time ofsetting of hydraulic cement grout mixtures used in prep
3、laced-aggregate (PA) concrete using the vicat apparatus.1.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appr
4、o-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 191 Test Methods for Time of Setting of HydraulicCement by Vicat NeedleC 938 Practice for Proportioning Grout Mixtures forPreplaced-Aggregate Conc
5、reteC511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and Concretes3. Summary of Method3.1 The time of setting, initial and final, of a sample of fluidgrout is determined using the Vicat apparatus.4. Significance and Use4
6、.1 This test method determines the setting time of groutmixed to the fluid consistency required for its use in PAconcrete.4.2 The time of setting is also useful in determining theacceptability of components of grout that must be mixed to thefluid consistency required for production of PA concrete.5.
7、 Apparatus5.1 Vicat Apparatus, in accordance with Test Method C 191.5.2 Moist Room, maintained in accordance with Specifica-tion C511.6. Test Sample6.1 The test sample shall consist of at least 300 mL of grouttaken from a freshly-mixed batch prepared in accordance withPractice C 938 obtained from a
8、mixer at the laboratory orconstruction site.7. Procedure7.1 Warm the Vicat conical ring and base plate to approxi-mately 100 C.7.2 Apply a thin film of paraffin wax to the base of theconical ring and place the waxed conical ring on the base plate.Place a weight on the conical ring to ensure intimate
9、 contactwith the base plate and allow the conical ring and plate to coolto room temperature.7.3 Fill the conical ring apparatus with grout flush with itstop within 2 min after completion of mixing. Strike off thegrout flush with the top of the conical ring by a single obliquestroke of a sharp-edged
10、trowel held at a slight angle to the topof the ring. Smooth the top, if necessary, with a few lighttouches of the pointed end of the trowel. Take care not tocompress the sample during these cutting and smoothingoperations. The time of completion of molding shall be takenas the start of measurement o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC9532006STANDARDTESTMETHODFORTIMEOFSETTINGOFGROUTSFORPREPLACEDAGGREGATECONCRETEINTHELABORATORY 实验

链接地址:http://www.mydoc123.com/p-508950.html