ASTM C898 C898M-2009 Standard Guide for Use of High Solids Content Cold Liquid-Applied Elastomeric Waterproofing Membrane With Separate Wearing Course《与分层磨损层一同使用的冷却液用含大量固体物质的弹性防水薄膜.pdf
《ASTM C898 C898M-2009 Standard Guide for Use of High Solids Content Cold Liquid-Applied Elastomeric Waterproofing Membrane With Separate Wearing Course《与分层磨损层一同使用的冷却液用含大量固体物质的弹性防水薄膜.pdf》由会员分享,可在线阅读,更多相关《ASTM C898 C898M-2009 Standard Guide for Use of High Solids Content Cold Liquid-Applied Elastomeric Waterproofing Membrane With Separate Wearing Course《与分层磨损层一同使用的冷却液用含大量固体物质的弹性防水薄膜.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 898/C 898M 09Standard Guide forUse of High Solids Content, Cold Liquid-AppliedElastomeric Waterproofing Membrane with SeparateWearing Course1This standard is issued under the fixed designation C 898/C 898M; the number immediately following the designation indicates the yearof original
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes the use of a high solids content,cold liquid-a
3、pplied elastomeric waterproofing membrane thatmeets the criteria in Specification C 836, in a waterproofingsystem subject to hydrostatic pressure for building decks overoccupied space where the membrane is covered with a separateprotective wearing course.1.2 The values stated in either SI units or i
4、nch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard does not purpo
5、rt to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C33
6、Specification for Concrete AggregatesC 578 Specification for Rigid, Cellular Polystyrene ThermalInsulationC 717 Terminology of Building Seals and SealantsC 836 Specification for High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane for Usewith Separate Wearing CourseC 920 Speci
7、fication for Elastomeric Joint SealantsC 1193 Guide for Use of Joint SealantsC 1299 Guide for Use in Selection of Liquid-Applied Seal-antsC 1471 Guide for the Use of High Solids Content ColdLiquid-Applied Elastomeric Waterproofing Membrane onVertical SurfacesC 1472 Guide for Calculating Movement and
8、 Other EffectsWhen Establishing Sealant Joint WidthD 1056 Specification for Flexible Cellular MaterialsSponge or Expanded Rubber,D 1751 Specification for Preformed Expansion Joint Fillerfor Concrete Paving and Structural Construction (Nonex-truding and Resilient Bituminous Types)D 1752 Specification
9、 for Preformed Sponge Rubber Corkand Recycled PVC Expansion Joint Fillers for ConcretePaving and Structural ConstructionD 5295 Guide for Preparation of Concrete Surfaces forAdhered (Bonded) Membrane Waterproofing SystemsD 5957 Guide for Flood Testing Horizontal WaterproofingInstallationsD 6134 Speci
10、fication for Vulcanized Rubber Sheets Used inWaterproofing SystemsD 6451 Guide for Application of Asphalt Based ProtectionBoardD 6506 Specification for Asphalt Based Protection Boardfor Below-Grade WaterproofingE 1907 Guide to Methods of Evaluating Moisture Condi-tions of Concrete Floors to Receive
11、Resilient Floor Cov-erings32.2 American Concrete Institute Standard:ACI 301 Specifications for Structural Concrete for Build-ings43. Terminology3.1 For definitions of terms used in the guide, refer toTerminology C 717.3.2 Definitions of Terms Specific to This Standard:3.2.1 cold-appliedcapable of be
12、ing applied without heat-ing as contrasted to hot-applied. Cold-applied products arefurnished in a liquid state, whereas hot-applied products arefurnished as solids that must be heated to liquefy them.1This guide is under the jurisdiction of ASTM Committee D08 on Roofing andWaterproofing and is the
13、direct responsibility of Subcommittee D08.22 on Water-proofing and Dampproofing Systems.Current edition approved June 15, 2009. Published July 2009. Originallyapproved in 1978. Last previous edition approved in 2001 as C 898 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or
14、contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4Available from ACI International, P.O
15、. Box 9094, Farmington Hills, MI4833-9094.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.2 curing timethe period between application and thetime when the material reaches its design physical properties.3.2.3 deflectionthe deviat
16、ion of a structural element fromits original shape or plane due to physical loading, temperaturegradients, or rotation of its supports.3.2.4 drainage boardsee prefabricated drainage compos-ite, the preferred term.3.2.5 drainage coursesee percolation layer and Fig. 1.3.2.6 flashinga generic term desc
17、ribing the transitionalarea between the waterproofing membrane and surfaces abovethe wearing surface of the building deck; a terminal closure orbarrier to prevent ingress of water into the system.3.2.7 freeze-thaw cyclethe freezing and subsequent thaw-ing of a material.3.2.8 percolation layer (drain
18、age course)a layer ofwashed gravel or of a manufactured drainage media that allowswater to filter through to the drain (see Fig. 1).3.2.9 prefabricated drainage compositeproprietary de-vices to facilitate drainage, usually a composite laminate ofmore than one material including filter fabric.3.2.10
19、structural slaba horizontal, supporting, cast-in-place, concrete building deck. See Fig. 1.3.2.11 troweled finisha concrete finish provided bysmoothing the surface with power driven or hand trowels orboth, after the float finishing operation. A troweled finish issmoother than the floated finish. For
20、 specifications, see ACI301.3.2.12 wearing surfacea surface exposed to traffic, eitherpedestrian or vehicular, also described as finish wearingsurface.3.2.13 wet-film thicknessthe thickness of a liquid coatingas it is applied.3.2.14 wet-film gagea gage for measuring the thickness ofa wet film.4. Sig
21、nificance and Use4.1 Designers and installers of waterproofing systems mayconsult this guide for a discussion of important elements of theuse of cold liquid-applied waterproofing membranes and asso-ciated elements of construction. This guide is not intended toserve as a specification for waterproofi
22、ng installation.4.2 Long-term performance of waterproofing with a sepa-rate wearing course is important because of the substantialdifficulty in determining the location of leakage and in remov-ing overlying materials to make repairs.4.3 Refer to Guide C 1471 for application on below gradewalls and v
23、ertical surfaces.5. General5.1 Major Components, Subsystems, and FeaturesThemajor components to be considered for a building deckwaterproofing system are the structural building deck orsubstrate to be waterproofed, waterproofing membrane, protec-tion of the membrane, drainage, insulation, and wearin
24、g course(see Fig. 1).Additional features to be considered are membraneterminal conditions and expansion joints.5.2 CompatibilityIt is essential that all components andcontiguous elements be compatible and coordinated to form atotally integrated waterproofing system.6. Substrate6.1 GeneralThe buildin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC898C898M2009STANDARDGUIDEFORUSEOFHIGHSOLIDSCONTENTCOLDLIQUIDAPPLIEDELASTOMERICWATERPROOFINGMEMBRANEWITHSEPARATEWEARINGCOURSE

链接地址:http://www.mydoc123.com/p-508702.html