ASTM C786-1996(2003) Standard Test Method for Fineness of Hydraulic Cement and Raw Materials by the 300-&956 m (No 50) 150-&956 m (No 100) and 75-&956 m (No 200) Sieves by Wet Meth.pdf
《ASTM C786-1996(2003) Standard Test Method for Fineness of Hydraulic Cement and Raw Materials by the 300-&956 m (No 50) 150-&956 m (No 100) and 75-&956 m (No 200) Sieves by Wet Meth.pdf》由会员分享,可在线阅读,更多相关《ASTM C786-1996(2003) Standard Test Method for Fineness of Hydraulic Cement and Raw Materials by the 300-&956 m (No 50) 150-&956 m (No 100) and 75-&956 m (No 200) Sieves by Wet Meth.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 786 96 (Reapproved 2003)Standard Test Method forFineness of Hydraulic Cement and Raw Materials by the300-m (No. 50), 150-m (No. 100), and 75-m (No. 200)Sieves by Wet Methods1This standard is issued under the fixed designation C 786; the number immediately following the designation ind
2、icates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers wet sieving tech
3、niques fordetermination of fineness of hydraulic cement and raw mate-rials by means of the 300-m (No. 50), the 150-m (No. 100),and the 75-m (No. 200) sieves.1.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if
4、 any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 114 Test Methods for Chemical Analysis of Hydr
5、aulicCement2C 184 Test Method for Fineness of Hydraulic Cement bythe 150-m (No. 100) and 75-m (No. 200) Sieves3C 430 Test Method for Fineness of Hydraulic Cement bythe 45-m (No. 325) Sieve2E 11 Specification for Wire Cloth and Sieves for TestingPurposes43. Apparatus3.1 Wet Test SievesStandard 300-m
6、(No. 50), 150-m(No. 100), or 75-m (No. 200) sieve cloth conforming to therequirements of Specification E 11, for standard sieves shall bewoven from AISI Type 304 wire. The cloth shall be mounted inthe frame without distortion, looseness, or wrinkling. Sieveframes are designated as 76.2 or 101.6-mm (
7、3 or 4-in.)diameter type, as follows:Sieves76 mm(3-in.)mm (in.)102 mm(4-in.)mm (in.)Diameter of frame 76 6 6(3.0 6 0.25)102 6 6(4.0 6 0.25)Depth of sieve from top of frame 83 6 6(3.25 6 0.25)108 6 6(4.25 6 0.25)Overall height 102 6 6(4.0 6 0.25)127 6 6(5.0 6 0.25)3.1.1 For a sieve fabricated by sold
8、ering the cloth to theframe, the joint shall be made smooth to prevent material fromlodging in the joints between the sieve cloth and the frame.Two-piece sieves shall clamp tightly on the cloth to preventparticles from lodging in the joints between the sieve cloth andthe frame, and shall have legs o
9、f sufficient length, 19-mm(0.75-in.) minimum, to allow air circulation beneath the sievecloth.3.2 Spray Nozzleconforming to the requirements of TestMethod C 430. Nozzles having an alternative design areacceptable if the sieve test results agree with those performedusing a nozzle conforming to Test M
10、ethod C 430.3.3 Pressure Gageconforming to the requirements of TestMethod C 430.3.4 Balanceanalytical, accurate to within 0.005 g.3.5 WeightsThe weights used in fineness determinationsshall conform to the requirements of Test Methods C 114.3.6 BrushA nylon or pure bristle brush will be requiredfor u
11、se in cleaning the sieves. A 13-mm (0.5-in.) diameterround-style brush with a 229-mm (9-in.) handle is a convenientsize. (WarningDo not use brass or steel-bristle brushes forcleaning sieves due to the possibility that the stiff bristle willpart the wire weave, thereby altering the size of the openin
12、gsand rendering the sieve useless. A 13-mm (12-in.) hog bristlestencil brush is also satisfactory for brushing sieves.)3.7 Dry Test SievesThe standard samples for calibratingthe wet test sieves must be standardized on 203-mm (8-in.)diameter sieves meeting the requirements of Test MethodC 184. The 30
13、0-m (No. 50) sieve shall meet the samerequirements.1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.25 on Fineness.Current edition approved June 10, 2003. Published August 2003. Originallyapproved in 1974. Last previous e
14、dition approved in 1996 as C 786 96.2Annual Book of ASTM Standards, Vol 04.01.3Discontinued. See 1993 Annual Book of ASTM Standards, Vol 4.01.4Annual Book of ASTM Standards, Vol 14.02.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3
15、.8 NBS SRM No. 1004Glass Bead Standard.4. Dry Sieve Standardization4.1 Correction Factors:4.1.1 Correction of the residues obtained on the 203-mm(8-in.) diameter 300-m (No. 50) and 150-m (No. 100) drytesting sieves is not required.4.1.2 Where applicable, a correction factor for a 75-m (No.200) sieve
16、 shall be determined using the instructions given inAnnex A1. A correction factor should be determined whenaccuracy is desired in order to compare results betweenlaboratories.4.2 Standard SamplesEach laboratory must prepare itsown standard samples for wet-sieve tests for each of the sievesizes used.
17、 Select standard samples at a level of fineness in thesame range as that used in routine work. After the selectedmaterial is reserved, uniformly mix the gross sample byplacing it on a sheet of rubber, oil cloth, or heavy wrappingpaper, depending on the sample size, and raising first onecorner of the
18、 sheet and then the other so as to roll the sampleover and over at least 100 times. Temporarily seal the preparedstandard material in airtight containers during the standardiza-tion procedure prior to sealing small portions as standardsamples in vials. Using the 203-mm (8-in.) diameter sievesfrom 3.
19、7, perform the dry sieving tests, following the proce-dure of Test Method C 184. Repeat the test three times and usethe average of the amounts passing, expressed as percent, asthe standard value of the sample. Use this standard sample tocalibrate the wet sieves. Place the entire sample in airtight v
20、ialsas soon as possible to prevent changes due to humidity. Vialsshall be prepared in denominations such as to contain approxi-mately 50 g for standardizing the 300-m (No. 50); 25 g for the150-m (No. 100); or 10 g for the 75-m (No. 200) sieve.5. Wet Sieve Calibration5.1 Weigh the contents of the app
21、licable size standardsample vial for the desired sieve determination on a balance ofappropriate sensitivity to the nearest 0.01 g. Record the weightand transfer the sample quantitatively to a clean dry wet test300-m (No. 50), 150-m (No. 100), or 75-m (No. 200) sieveand proceed as directed in Section
22、 6. The sieve correctionfactor is the difference between the test residue obtained andthe residue value indicated by the standardization tests ofSection 4, expressed as a percentage of the test residue. Thisfactor is expressed as follows:C 5Rs 3 Wt/100! 2 RtRt3 100 (1)where:C = sieve correction fact
23、or (which may be either plus orminus), %,Rt= test residue from sample retained on sieve, g,Rs= standard residue retained on sieve, %, andWt= weight of test sample, g.5.1.1 Example of Determination of Wet Sieve Calibration:% Residue on 150-m (No. 100) sieve forstandard sample, Rs= 5.40%Residue from t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC78619962003STANDARDTESTMETHODFORFINENESSOFHYDRAULICCEMENTANDRAWMATERIALSBYTHE300956MNO50150956MNO100AND75956MNO200SIEVESBYWETMETHPDF

链接地址:http://www.mydoc123.com/p-508371.html