ASTM C703-1972(2016) Standard Test Methods for Spalling Resistance of Porcelain Enameled Aluminum《铝制搪瓷涂层的抗脱落试验方法》.pdf
《ASTM C703-1972(2016) Standard Test Methods for Spalling Resistance of Porcelain Enameled Aluminum《铝制搪瓷涂层的抗脱落试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C703-1972(2016) Standard Test Methods for Spalling Resistance of Porcelain Enameled Aluminum《铝制搪瓷涂层的抗脱落试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C703 72 (Reapproved 2016)Standard Test Methods forSpalling Resistance of Porcelain Enameled Aluminum1This standard is issued under the fixed designation C703; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、 last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test, using an ammonium chloride or antimony trichloride test solution, covers an acceleratedprocedure for deter
3、mining the resistance of porcelain enamel coatings on aluminum and aluminumalloys to spontaneous loss of adhesion (spalling) resulting from exposure to moisture, weathering, orother environmental stress.1. Scope1.1 These test methods cover accelerated determination ofthe resistance of porcelain enam
4、el coatings on aluminum alloysto spalling from exposure to moisture or weathering. TestMethod A,2using a 5 % solution of ammonium chloride,requires 96-h immersion while Test Method B,3using a 1 %solution of antimony trichloride, is completed after 20 h ofimmersion. The spalling tendency is evaluated
5、 by the samecriteria in both methods. While either method is suitable formagnesium silicon alloys, such as 6061, Test Method B ispreferred for simple alloys or commercially pure aluminum,such as 1100.1.2 The test methods appear in the following order:SectionsTest Method AAmmonium Chloride 49Test Met
6、hod BAntimony Trichloride 10152. Terminology2.1 Definitions:2.1.1 spallinga defect characterized by separation of theporcelain enamel from the aluminum base metal withoutapparent external cause. Spalling can result from the use ofimproper alloys or enamel formulations, incorrect pretreatmentof the b
7、ase metal, or faulty application and firing procedures.3. Significance and Use3.1 It is difficult to overemphasize the importance of thespall test. Porcelain enameled aluminum that fails this test willprobably spall in service if subjected to moisture or weather-ing.TEST METHOD AAMMONIUM CHLORIDE4.
8、Apparatus4.1 Container, glass or plastic, large enough to immerse thetest area of the specimen completely and hold a minimum of 3mL of solution per square centimetre of the immersed surface.No metal other than the base metal of the specimen may beexposed to the test solution.5. Reagent5.1 Ammonium C
9、hloride Solution (5 %)The test solution,freshly prepared, shall consist of 5 parts, by mass, of ammo-nium chloride (NH4Cl) (technical grade is adequate) dissolvedin 95 parts, by mass, of water. Deionized or distilled water ispreferred, but in the case of very large production pieces, tapwater may be
10、 used. Sufficient solution shall be prepared topermit complete immersion of the specimens.6. Test Specimens6.1 Full-size production pieces should be tested. When thisis not practical, specimens approximately 4 by 6 in. (102 by152 mm), cut from production parts should be tested. At leastone represent
11、ative specimen from each “job” or each 1000 ft2(93 m2) of production, whichever is applicable, should be spalltested. Spall-tested pieces should not be shipped.6.2 Test production parts in as-produced condition.7. Procedure7.1 Immerse the test specimens completely in the NH4Clsolution at room temper
12、ature. Large production pieces may be1These test methods are under the jurisdiction of ASTM Committee B08 onMetallic and Inorganic Coatings and are the direct responsibility of SubcommitteeB08.12 on Materials for Porcelain Enamel and Ceramic-Metal Systems.Current edition approved Nov. 1, 2016. Publi
13、shed November 2016. Originallyapproved in 1972. Last previous edition approved in 2011 as C703 72 (2011).DOI: 10.1520/C0703-72R16.2Method A is based on Bulletin AL-1a, Recommended Test Methods forEvaluation and Control of Quality of Porcelain Enamel on Aluminum ,ofthePorcelain Enamel Institute.3Meth
14、od B is based on Bulletin T-51, Antimony Trichloride Spall Test ofPorcelain Enameled Aluminum, of the Porcelain Enamel Institute.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1immersed in a container made by lining a packing box with
15、polyethylene plastic sheeting.7.2 Make a visual inspection after 96 h of immersion.NOTE 1Variations of this test may be used for studies of processingvariables. These include scored or deformed samples, 24 h inspection, andmultiple cycles of 96 h each.8. Evaluation8.1 Any of the following types of s
16、pall that develop within96 h shall constitute failure:8.1.1 Any spall area (revealing bare metal) extending18 in.(3 mm), or more, in from an edge and more than 1 in. (25 mm)in length,8.1.2 Any spall area on the interior surface (not touching anedge) that is more than18 in. (3 mm) to its maximumdimen
17、sion, or8.1.3 More than six visible spall spots per 1 ft2(929 cm2)onthe interior surface.9. Report9.1 The report shall include the following:9.1.1 Evaluation of the specimen as passing or failing theimmersion test in 96 h,9.1.2 Complete identification of the specimen, including thebasis metal, metal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC70319722016STANDARDTESTMETHODSFORSPALLINGRESISTANCEOFPORCELAINENAMELEDALUMINUM 铝制 搪瓷 涂层 脱落 试验 方法

链接地址:http://www.mydoc123.com/p-508064.html