ASTM C679-2003(2009)e1 Standard Test Method for Tack-Free Time of Elastomeric Sealants《弹性密封剂失效时间的标准试验方法》.pdf
《ASTM C679-2003(2009)e1 Standard Test Method for Tack-Free Time of Elastomeric Sealants《弹性密封剂失效时间的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C679-2003(2009)e1 Standard Test Method for Tack-Free Time of Elastomeric Sealants《弹性密封剂失效时间的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 679 03 (Reapproved 2009)1Standard Test Method forTack-Free Time of Elastomeric Sealants1This standard is issued under the fixed designation C 679; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1NOTEThe term “standard conditions was added to 3.1 in Mar
3、ch 2009.1. Scope1.1 This test method covers a procedure for the determina-tion of the tack-free time property of single- and multi-component elastomeric sealants commonly used for sealing,caulking, and glazing in buildings and related construction.1.2 This test method is applicable to self-leveling
4、andnon-sag grades of sealant. Sealants requiring slight heating tofacilitate extrusion from the cartridge or gun are also describedby this test method.NOTE 1See Specification C 920 for type and grade definitions.1.3 The values stated in metric units are to be regarded asthe standard. The values give
5、n in parentheses are provided forinformation purposes only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bi
6、lity of regulatory limitations prior to use.NOTE 2Currently, there is no ISO standard similar to this specifica-tion.2. Referenced Documents2.1 ASTM Standards:2C 717 Terminology of Building Seals and SealantsC 920 Specification for Elastomeric Joint Sealants3. Terminology3.1 DefinitionsSee Terminolo
7、gy C 717 for definitions ofthe following terms used in this test method: caulking, com-pound, cure, elastomeric, glazing, non-sag sealant, sealant,self-leveling sealant, and standard conditions.4. Summary of Test Method4.1 The test consists of lightly touching a surface of a curingsealant with a pol
8、yethylene film at regular intervals until thesealant does not attach itself to the film and the film appearsclean when peeled from the surface.4.2 More specifically a strip of polyethylene film is placedon the surface of the curing sealant and a 30-g (1.06-oz) weightis placed on the film. The weight
9、 is left in place for 30 s, thenremoved and the polyethylene strip is removed and examinedfor sealant attachment to the film. The length of time fromwhen the sealant was first applied and tooled into the templateuntil the time the sealant is no longer picked up by the film iscalled tack-free time.4.
10、3 With some sealants, interpretation of the end point isconfusing in that a very thin film of sealant or oil will transferto the film. For consistency of data, record the point where thebulk sealant is no longer transferred to the plastic but ignore thevery thin uniform film of sealant or the plasti
11、cizer transferredto the plastic test strip.5. Significance and Use5.1 The tack-free time is a measure of the surface cure timeand may generally be correlated to a variety of useful param-eters such as the time interval before the sealant (1) resistsdamage by touch or light surface contact, (2) resis
12、ts job-site orairborne dirt pick-up, (3) resists impinging rainfall.5.2 The tack-free time is sometimes used as an on-the-jobquality assurance test. A quality product that is consistent andreproducible will generally fall within a maximum and mini-mum tack-free time.5.3 This test for tack-free time
13、can be used at any tempera-ture and humidity. It is important that if a sealant will be usedin a climate quite different than the standard conditions calledout in this test method, then those conditions be used to test thesealant.1This test method is under the jurisdiction ofASTM Committee C24 on Bu
14、ildingSeals and Sealants and is the direct responsibility of Subcommittee C24.20 onGeneral Test Methods.Current edition approved Jan. 1, 2009. Published March 2009. Originallyapproved in 1971. Last previous edition approved in 2003 as C 679 03.2For referenced ASTM standards, visit the ASTM website,
15、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.
16、 Apparatus6.1 Cabinet or Room, capable of maintaining a temperatureof 23 6 2C (73.4 6 3.6F) and 50 % 6 5 % relative humidity.6.2 Weight, rectangular, with dimensions of 41 by 19 mm(158 in. long by34 in. wide) and mass of 30 g (1.06 oz).NOTE 3The thickness of the weight should be approximately 6 mm(1
17、4 in.) but planed to a thickness that will provide the 30-g (1.06-oz) mass.6.3 Polyethylene Strips, several (often 6 or more), clear, lowdensity with dimensions 127 by 25 by 0.15 mm (5 by 1 by0.006 in.).6.4 Timer, capable of measuring minutes and hours.6.5 Rectangular Plates, several (often 6 or mor
18、e), rectangu-lar, approximately 152 by 76 mm (6 by 3 in.), made ofnon-porous material such as tin plated steel or aluminum.6.6 Template, rectangular, of steel, brass or other suitablematerial, 3.2 mm (18 in.) thick with inside dimensions 95 by25.4 mm (334 by 1 in.); outside dimensions approximately
19、120by 31 mm (534 by 2 in.).7. Sampling7.1 The test sample shall consist of a factory-sealed can ofcompound (minimum contents, 450 mL or 1 pt) with anappropriate curing agent where applicable, or a standardcartridge, factory filled and sealed.8. Procedure (see Fig. 1)8.1 Thoroughly clean the template
20、s and rectangular plateswith methyl ethyl ketone, xylene, or similar solvent.(WarningMethyl ethyl ketone, xylene, and similar solventsare both toxic and flammable and should be handled withcaution in a well ventilated hood.)8.2 Condition the sample of sealant in the original closedcontainer for 24 h
21、 at 23 6 2C (73.4 6 3.6F) and 50 6 5%relative humidity. For single-component sealants, weigh outapproximately 250 g of the sealant before testing. For multi-component sealants, thoroughly mix 250 g of the base com-pound with the appropriate amount of curing agent followingthe manufacturers mixing in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC67920032009E1STANDARDTESTMETHODFORTACKFREETIMEOFELASTOMERICSEALANTS 弹性 密封剂 失效 时间 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-507999.html