1、Designation: C 577 071Standard Test Method forPermeability of Refractories1This standard is issued under the fixed designation C 577; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthese
2、s indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits of measure statement was added editorially in March 2009.1. Scope1.1 This test method covers determination of the permeabil-ity of refractory brick and mono
3、liths, from which suitablespecimens can be cut, at room temperature.1.2 UnitsThe values stated in inch-pound units are to beregarded as standard. The values given in parentheses aremathematical conversions to SI units that are provided forinformation only and are not considered standard.1.2.1 Except
4、ionsThe apparatus used in this standard isonly available in SI units (Section 4). Also, some of thecalculations must use SI units only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to est
5、ablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C1095 Practice for Calculating Precision Data on Refracto-ries (C08) from Interlaboratory Test Results.33. Significance and Use3.1 This t
6、est method is used to measure the rate of flow ofair or nitrogen through refractory brick and monoliths and tothus determine the permeability of tested products.3.2 This test method is useful in research and developmentfor establishing the relative permeability of products withincomparable classes.
7、It may also be used to identify acceptableproducts for design purposes and to establish permeabilitycriteria for specification acceptance.3.3 It must be recognized that permeability can vary indifferent directions and different parts of a refractory due tofactors such as forming procedure, grain siz
8、e and distribution,and heat treatment.4. Apparatus4.1 The apparatus shall provide a leakproof system fortesting 2 in. (51 mm) cubes held in a pressurized rubber gasket,with means for controlling gas pressure and measuring gasflow. Figs. 1-3 illustrate a suitable apparatus.4The apparatusconsists of t
9、he following components:4.1.1 Permeating Medium, air or nitrogen with regulator-controlled inlet pressure.4.1.2 Drier Tubes, each filled with a desiccant and strainer;used to remove any water or dirt from the gas before enteringthe flowmeters.4.1.3 FlowmetersThey will measure the flow of permeat-ing
10、 media in the range from 0 to 9000 cm3/min. Theflowmeters may be calibrated to read the flow directly of eitherair or nitrogen. The range for each flowmeter is shown in Fig.1.4.1.4 ManometerAmultiple scale digital manometer shallbe used to measure the differential pressure across the speci-men.4.1.5
11、 Rubber Specimen-Sealing GasketThe gasket (Fig.2) is made to fit tightly arounda2by2by2in.(51by51by51 mm) test specimen. The two tapered metal-gasket holders(Fig. 3) enclose the rubber gasket, and are compressed with ahydraulic jack (Fig. 4) to seal the gasket tightly against the testspecimen.5. Spe
12、cimen Preparation5.1 One 2 by 2 by 2 in. (51 by 51 by 51 mm) specimen shallbe cut from each of four pieces constituting the sample ofmaterial to be tested. The specimen should be cut in such amanner as to fit snugly into the gasket.5.2 The specimens shall be cut so that three originalsurfaces are re
13、tained. In cases where it is desirable to determine1This test method is under the jurisdiction of ASTM Committee C08 onRefractories and is the direct responsibility of Subcommittee C08.03 on PhysicalProperties.Current edition approved June 1, 2007. Published July 2007. Originally approvedin 1965. La
14、st previous edition approved in 1999 as C 577 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3C084The app
15、aratus is described in Eusner, G. R., and Shapland, J. T., “Permeabilityof Blast-Furnace Refractories,” Journal, Am. Ceramic Soc., Vol. 42, No. 10, 1959,pp. 459464.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the permeability of s
16、pecimens that show directional differencesin permeability, the original surfaces shall be identified, and thevalues determined separately for each direction of gas flow.AFlowmeter (3 to 80 cm3/min) GMercury ManometerBFlowmeter (10 to 180 cm3/min) HNeedle ValveCFlowmeters (100 to 1500 cm3/min) JPress
17、ure-Release ValveDFlowmeters (500 to 9000 cm3/min) KGasket HolderEDrying Tubes LHydraulic JackFWater Manometer MPressure RegulatorNGas Supply (Permeating Medium)FIG. 1 Permeability ApparatusC5770712FIG. 1 Permeability Apparatus (continued)SI Equivalentsin. 1 15/16 2 4mm 49 51 102FIG. 2 Rubber Specim
18、en-Sealing GasketSI Equivalentsin.14 212 4mm 6 64 102FIG. 3 Tapered Stainless Steel Gasket HolderC57707135.3 The specimens shall be dried for 16 h at 220 to 230F(105 to 110C) and cooled to room temperature before testing.After drying, all specimen surfaces shall be blown free of dustwith clean dry a
19、ir and tested within 4 h.6. Procedure6.1 Check the system for leaks. This may be accomplishedby taking readings with an impermeable material in thespecimen holder or by utilizing flowmeters in the line ahead ofthe test specimen.6.2 Place the specimen in the rubber gasket, and enclose itbetween the t
20、wo halves of the gasket holder. Force the halvesof the gasket holder together to seal the specimen in the gasket.6.3 Pass dried air (or nitrogen) through the specimen toproduce a differential pressure across the specimen of 240 mmHg (32.0 kPa) and measure the rate of air (or nitrogen) flow.Measure t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC5772007E1STANDARDTESTMETHODFORPERMEABILITYOFREFRACTORIESPDF

链接地址:http://www.mydoc123.com/p-467064.html