ASTM C559-1990(2005) Standard Test Method for Bulk Density by Physical Measurements of Manufactured Carbon and Graphite Articles《用物理测量法测定碳加工品及石墨制品松密度的试验方法》.pdf
《ASTM C559-1990(2005) Standard Test Method for Bulk Density by Physical Measurements of Manufactured Carbon and Graphite Articles《用物理测量法测定碳加工品及石墨制品松密度的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C559-1990(2005) Standard Test Method for Bulk Density by Physical Measurements of Manufactured Carbon and Graphite Articles《用物理测量法测定碳加工品及石墨制品松密度的试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 559 90 (Reapproved 2005)An American National StandardStandard Test Method forBulk Density by Physical Measurements of ManufacturedCarbon and Graphite Articles1This standard is issued under the fixed designation C 559; the number immediately following the designation indicates the year
2、 oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the bulkde
3、nsity of manufactured articles of carbon and graphite of atleast 500 mm3volume. The bulk density is calculated to anaccuracy of 0.25 %, using measurements of mass and dimen-sions in air at 25 6 5C.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its us
4、e. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2IEEE/ASTM SI-10 Standard for Use of the InternationalSystem of Units (SI) (
5、the Modern Metric System)3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 bulk density the mass of a unit volume of materialincluding both permeable and impermeable voids.4. Significance and Use4.1 Bulk density as determined by this test method is a basicmaterial property of im
6、portance in manufacturing and applica-tion of carbon and graphite.4.2 This test method can be used for quality and processcontrol, material characterization and description, and otherpurposes.5. Preparation of Test Specimens5.1 Machine test specimens from the manufactured articlein the form of a rec
7、tangular parallelepiped or a right circularcylinder. The minimum mass of the specimen shall be 2000times the sensitivity of the balance used to weigh the specimen,and the volume of the specimen shall not be less than 500 mm3.The minimum dimension of the specimen shall be the larger of:5.1.1 Ten time
8、s the length of the largest visible particle, and5.1.2 2000 times the resolution of the device used formeasuring the dimension.5.2 During the machining operation, use no lubricant havinga boiling point above 100C. All corners, edges, and faces ofthe specimen should be free of chips or gouges. Ensure
9、 that thespecimen is free of any residue from the machining operation.Dry the specimen for a minimum of2hat110C, and thenallow it to cool to 25 6 5C in a desiccator. The specimen shallnot be removed from the desiccator until immediately prior toweighing.6. Procedure6.1 Weigh the specimen to an accur
10、acy of 0.05 % using abalance or scale. During the weighing operation, handle thespecimen with soft-tipped tongs.6.2 Measure each dimension of the test specimen to anaccuracy of 0.05 %.6.2.1 If the specimen is a rectangular parallelepiped, makefour measurements of the length (longest dimension). Take
11、each measurement along the center of each of the four longfaces of the specimen. Measure the width and thickness at eachend and at two intermediate points along the length of thespecimen. Determine the mean of each dimension.6.2.2 If the specimen is a right circular cylinder, measure thelength at fo
12、ur points, 90 apart on the periphery of the circularend faces. Make two sets of diameter measurements. Each setshall consist of four measurements, one at each end and two atintermediate points along an axial line. These sets shall lie at90 to each other. Determine the mean length and the mean ofeach
13、 of the two sets of diameter measurements.7. Calculation7.1 Convert the mass to milligrams and the dimensions tomillimetres, or convert the mass to megagrams and thedimensions to metres. Conversion factors are available inIEEE/ASTM SI-10.7.2 The volume of the specimen may be calculated asfollows:1Th
14、is test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.F0 on Manufactured Carbon and Graphite Products.Current edition approved June 1, 2005. Published August 2005. Originallyapproved in 1968. Last previo
15、us edition approved in 2000 as C 55990(2000).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC55919902005STANDARDTESTMETHODFORBULKDENSITYBYPHYSICALMEASUREMENTSOFMANUFACTUREDCARBONANDGRAPHITEARTICLES

链接地址:http://www.mydoc123.com/p-467019.html