ASTM C533-2007 Standard Specification for Calcium Silicate Block and Pipe Thermal Insulation《硅酸钙块和管状隔热材料的标准规范》.pdf
《ASTM C533-2007 Standard Specification for Calcium Silicate Block and Pipe Thermal Insulation《硅酸钙块和管状隔热材料的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C533-2007 Standard Specification for Calcium Silicate Block and Pipe Thermal Insulation《硅酸钙块和管状隔热材料的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 533 07Standard Specification forCalcium Silicate Block and Pipe Thermal Insulation1This standard is issued under the fixed designation C 533; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers calcium silicate block a
3、nd pipethermal insulation for use on surfaces with temperaturesbetween 80 and 1700F (27 to 927C), unless otherwise agreedupon between the manufacturer and the purchaser.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation onl
4、y.1.3 The following safety hazards caveat pertains only to thetest method (Section 12) described in this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate s
5、afety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2C 165 Test Method for Measuring Compressive Propertiesof Thermal InsulationsC 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State
6、Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 203 Test Methods for Breaking Load and Flexural Prop-erties of Block-Type Thermal InsulationC 302 Test Method for Density and Dimensions of Pre-formed Pipe-Covering-Type Thermal InsulationC 303 Te
7、st Method for Dimensions and Density of Pre-formed Block and BoardType Thermal InsulationC 335 Test Method for Steady-State Heat Transfer Proper-ties of Pipe InsulationC 356 Test Method for Linear Shrinkage of PreformedHigh-Temperature Thermal Insulation Subjected to Soak-ing HeatC 390 Practice for
8、Sampling and Acceptance of ThermalInsulation LotsC411 Test Method for Hot-Surface Performance of High-Temperature Thermal InsulationC 421 Test Method for Tumbling Friability of PreformedBlock-Type Thermal InsulationC 446 Test Method for Breaking Load and CalculatedModulus of Rupture of Preformed Ins
9、ulation for Pipes3C 450 Practice for Fabrication of Thermal Insulating FittingCovers for NPS Piping, and Vessel LaggingC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 585 Practice for Inner and Outer Diameters of RigidThermal Insulation fo
10、r Nominal Sizes of Pipe and Tubing(NPS System)C 795 Specification for Thermal Insulation for Use in Con-tact with Austenitic Stainless SteelC 870 Practice for Conditioning of Thermal Insulating Ma-terialsC 1045 Practice for Calculating Thermal TransmissionProperties Under Steady-State ConditionsC 10
11、58 Practice for Selecting Temperatures for Evaluatingand Reporting Thermal Properties of Thermal InsulationC 1114 Test Method for Steady-State Thermal TransmissionProperties by Means of the Thin-Heater ApparatusC 1616 Test Method for Determining the Moisture Contentof Inorganic Insulation Materials
12、by WeightE84 Test Method for Surface Burning Characteristics ofBuilding Materials3. Terminology3.1 DefinitionsFor definitions used in this specification,see Terminology C 168.4. Classification4.1 Thermal insulation shall be of the following types:4.1.1 Type IBlock for use on surfaces at temperature
13、from140F (60C) to to 1200F (649C).1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.20 onHomogeneous Inorganic Thermal Insulations.Current edition approved March 1, 2007. Published March 2007. Originallyappro
14、ved in 1964 to replace C 344 and C 345. Last previous edition approved in2004 as C 533 04.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Sum
15、mary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.2 Type IPipe for use on surfaces at temperature from140F (60C) to to 1200F (649C).4.1.3 Type IABlock for use on surfaces at temperaturesfrom
16、140F (60C) to to 1200F (649C).4.1.4 Type IIBlock for use on surfaces at temperaturesfrom 140F (60C) to 1700F (927C).5. Description5.1 CompositionCalcium silicate thermal insulation shallconsist principally of hydrous calcium silicate usually with theincorporation of fibrous reinforcement. Asbestos s
17、hall not beused as a component in the manufacture of the material.6. Physical Requirements6.1 The insulation shall conform to the physical require-ments of Table 1.7. Standard Shapes, Sizes, and Dimensions7.1 Calcium silicate block-type thermal insulation shall besupplied in the form of pipe insulat
18、ion, flat block or curvedblocks as specified. Standard sizes of the block type insulationshall be as follows:7.1.1 Flat BlockFlat block shall be furnished in lengths of36 in. (458 or 914 mm), widths of 6 to 36 in. (152 to 914 mm),and thicknesses from 1 to 6 in. (25 to 152 mm) in12-in.(13-mm) increme
19、nts. Thicknesses greater than 3 in. (76 mm)shall be furnished in one or more layers as agreed upon bypurchaser and manufacturer.7.1.2 Curved BlockCurved block shall be furnished inlengths of 36 in. (914 mm), widths of approximately 6 to 12 in.(152 or 305 mm), thicknesses of 112 to 4 in. (38 to 101 m
20、m) in12-in. (13-mm) increments, and curved to inside radii of over1612 in. (419 mm). Individual dimensions shall conform tothose specified by the manufacturer.7.1.3 Grooved BlockGrooved block shall be furnished inlengths of 36 in. (914 mm), widths of 12 or 18 in. (305 or 458mm), and thicknesses from
21、 1 to 6 in. (25 to 152 mm) in12-in.(13-mm) increments. Size and spacing of grooves shall be asspecified by the manufacturer.7.2 Calcium Silicate Pipe InsulationCalcium silicate pipeinsulation shall be supplied either as hollow cylindrical shapessplit in half lengthwise (in a plane including the cyli
22、ndricalaxis) or as curved segments. The pipe insulation shall befurnished in sections or segments in a length of 36 in. (914mm) , unless otherwise agreed upon by the Purchaser, to fitstandard sizes of pipe and tubing, and in nominal wallthicknesses from 1 to 6 in. (25 to 152 mm), in12 in. (13 mm)inc
23、rements. Thicknesses greater than 3 in. (76 mm) shall befurnished in one or more layers as agreed upon by between thepurchaser and the manufacturer. Inner and outer diametersTABLE 1 Physical RequirementsNOTE 1The physical requirements are based on the properties of samples dried or conditioned, or b
24、oth, as specified in the referenced test methods.Calcium silicate insulation tends to absorb moisture to varying degrees depending on exposure conditions. It can absorb up to 4 times its dry weight ifplaced in direct contact with water through improper storage or application.NOTE 2The user is advise
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC5332007STANDARDSPECIFICATIONFORCALCIUMSILICATEBLOCKANDPIPETHERMALINSULATION 硅酸 管状 隔热材料 标准规范 PDF

链接地址:http://www.mydoc123.com/p-466932.html