ASTM C385-1958(2004)e1 Standard Test Method for Thermal Shock Resistance of Porcelain-Enameled Utensils《搪瓷器具抗热冲击性的试验方法》.pdf
《ASTM C385-1958(2004)e1 Standard Test Method for Thermal Shock Resistance of Porcelain-Enameled Utensils《搪瓷器具抗热冲击性的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C385-1958(2004)e1 Standard Test Method for Thermal Shock Resistance of Porcelain-Enameled Utensils《搪瓷器具抗热冲击性的试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 385 58 (Reapproved 2004)e1Standard Test Method forThermal Shock Resistance of Porcelain-Enameled Utensils1This standard is issued under the fixed designation C 385; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEKeywords were added editorially in September 2004.1. Scope1.1 This test method covers the determination of the res
3、is-tance of porcelain-enameled utensils to thermal shock. Thistest method is adaptable to any porcelain-enamel utensil thatcan be filled with water to a depth of 1 in. (25 mm).1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsib
4、ility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Apparatus2.1 Hot Plate, capable of maintaining over its entire surfacea uniform temperature, that is, less than 20F (6.7C) varia-tion ov
5、er the entire surface. Surface temperature of the hotplate shall be capable of being adjusted from 475 to825 6 10F (245 to 440 6 5.5C). The surface temperature ofthe hot plate, determined by any suitable surface temperaturemeasuring device, may be varied by changing the wattageinput to the hot plate
6、. If the hot plate surface temperature becalibrated to wattage input, the desired temperature may thenbe set by adjusting wattage input. The wattage input or similarcalibration shall be made for each surface temperature (see 6.2and 6.3).2.2 Timing Device, a clock or similar instrument having asweep
7、second hand and an integrating minute hand.2.3 Container, suitable for holding approximately 4 gal ofwater.2.4 Container, for pouring water into utensil.2.5 Sponge, for wiping utensil dry.3. Quenching Water3.1 Either tap or distilled water shall be used.NOTE 1In areas where tap water is extremely ha
8、rd, distilled water isrecommended.4. Test Specimens4.1 The test specimens shall consist of five identical uten-sils.NOTE 2“Identical utensils” signifies utensils of the same size, shape,and finish.5. Preparations for Test5.1 Level the hot plate. Switch on the hot plate and adjustthe surface temperat
9、ure to 475 6 10F (245 6 5.5C). Allowthe hot plate to preheat at this temperature for at least1htoobtain a uniform temperature over the entire heating surface.5.2 Place the quenching water in a large container. Adjustthe temperature of the water to 70 6 2F (21 6 1C). Measureout the amount of water re
10、quired to fill a test utensil to a depthof 1 in. (25 mm); this amount of water shall be used forquenching.NOTE 3The test utensils must be at room temperature at the start ofthe test.6. Procedure6.1 Center a dry utensil directly on the preheated hot plate.After 3 min remove the utensil from the hot p
11、late andimmediately fill the utensil to a depth of 1 in. (25 mm) withquenching water. After 10 s pour out the quenching water andwipe the inside of the utensil with a wrung-out damp sponge.After a total nonheating period of 20 s replace the utensil on thehot plate.6.2 Immediately after centering the
12、 utensil on the hot plate,adjust the input to the hot plate so that the hot plate surfacetemperature will reach 500 6 10F (260 6 5.5C). Allow theutensil to heat dry for 8 min with the hot plate adjusted so thatthis new surface temperature will be reached.NOTE 4Do not remove the utensil for surface t
13、emperature measure-ments during the test. The surface temperature of the hot plate should becalibrated against wattage input before the test is started. The surfacetemperature of the hot plate is the maximum temperature to be reachedduring the 8-min heating period (see 2.1).1This test method is unde
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC38519582004E1STANDARDTESTMETHODFORTHERMALSHOCKRESISTANCEOFPORCELAINENAMELEDUTENSILS 搪瓷 器具 抗热 冲击

链接地址:http://www.mydoc123.com/p-466422.html