1、Designation: C 188 95 (Reapproved 2003)American Association StateHighway and Transportation Officials StandardAASHTO No.: T133Standard Test Method forDensity of Hydraulic Cement1This standard is issued under the fixed designation C 188; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Depa
3、rtment of Defense.1. Scope1.1 This test method covers the determination of the densityof hydraulic cement. Its particular usefulness is in connectionwith the design and control of concrete mixtures.1.2 The density of hydraulic cement is defined as the massof a unit volume of the solids.1.3 The value
4、s stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility
5、 of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 114 Test Methods for Chemical Analysis of HydraulicCement2C 670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction Materials33. Apparatus3.1 Le Chatelier flaskThe standard flask, wh
6、ich is circularin cross section, with shape and dimensions conformingessentially to Fig. 1 (Note 1). The requirements in regard totolerance, inscription and length, spacing, and uniformity ofgraduation will be rigidly observed. There shall be a space ofat least 10 mm between the highest graduation m
7、ark and thelowest point of grinding for the glass stopper.3.1.1 The material of construction shall be excellent qualityglass, transparent and free of striae. The glass shall bechemically resistant and shall have small thermal hysteresis.The flasks shall be thoroughly annealed before being gradu-ated
8、. They shall be of sufficient thickness to ensure reasonableresistance to breakage.3.1.2 The neck shall be graduated from 0 to 1 mL and from18 to 24 mL in 0.1-mL graduations. The error of any indicatedcapacity shall not be greater than 0.05 mL.3.1.3 Each flask shall bear a permanent identification n
9、um-ber and the stopper, if not interchangeably ground, shall bearthe same number. Interchangeable ground-glass parts shall bemarked on both members with the standard-taper symbol,followed by the size designation. The standard temperatureshall be indicated, and the unit of capacity shall be shown byt
10、he letters “mL” placed above the highest graduation mark.1This test method is under the jurisdiction of ASTM Committee C01 on Cement,and is the direct responsibility of Subcommittee C01.25 on Fineness.Current edition approved June 10, 2003. Published August 2003. Originallyapproved in 1944. Last pre
11、vious edition approved in 1995 as C 188 95.2Annual Book of ASTM Standards, Vol 04.01.3Annual Book of ASTM Standards, Vol 04.02.NOTEVariations of a few millimetres in such dimensions as totalheight of flask, diameter of base, and so forth, are to be expected and willnot be considered sufficient cause
12、 for rejection. The dimensions of theflask shown in Fig. 1 apply only to new flasks and not to flasks in usewhich meet the other requirements of this test method.FIG. 1 Le Chatelier Flask for Density Test1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2
13、959, United States.3.2 Kerosine, free of water, or naphtha, having a densitygreater than 0.73 g/mL at 23 6 2 C shall be used in the densitydetermination.3.3 The use of alternative equipment or methods for deter-mining density is permitted provided that a single operator canobtain results within 6 0.
14、03 Mg/m3of the results obtainedusing the flask method.NOTE 1The design is intended to ensure complete drainage of theflask when emptied, and stability of standing on a level surface, as well asaccuracy and precision of reading.4. Procedure4.1 Determine the density of cement on the material asreceive
15、d, unless otherwise specified. If the density determina-tion on a loss-free sample is required, first ignite the sample asdescribed in the test for loss on ignition in section 16.1 onPortland Cement of Test Methods C 114.4.2 Fill the flask (Note 2) with either of the liquids specifiedin 3.2 to a poi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC18819952003STANDARDTESTMETHODFORDENSITYOFHYDRAULICCEMENT 硬性 水泥 密度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-465956.html