ASTM C1729-2013 Standard Specification for Aluminum Jacketing for Insulation《绝缘铝护套的标准规格》.pdf
《ASTM C1729-2013 Standard Specification for Aluminum Jacketing for Insulation《绝缘铝护套的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1729-2013 Standard Specification for Aluminum Jacketing for Insulation《绝缘铝护套的标准规格》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1729 13Standard Specification forAluminum Jacketing for Insulation1This standard is issued under the fixed designation C1729; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pare
2、ntheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers aluminum jacketing for ther-mal and acoustical insulation operating at either above orbelow ambient temperatures and in bot
3、h indoor and outdoorlocations. It does not cover insulation jacketing made fromother materials such as mastics, fiber reinforced plastic, PVC,or stainless steel nor does it cover the details of thermal oracoustical insulation systems.1.2 This specification provides physical requirements foraluminum
4、jacketing for thermal and acoustical insulation.Guide C1423 provides guidance in selecting jacketing materi-als and their safe use.1.3 This is a material specification and does not imply anyperformance of the installed system using the materials speci-fied herein. For information about installation
5、of aluminumjacketing, see (1).21.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of t
6、hesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3B209 Specification for Alu
7、minum and Aluminum-AlloySheet and PlateC168 Terminology Relating to Thermal InsulationC450 Practice for Fabrication of Thermal Insulating FittingCovers for NPS Piping, and Vessel LaggingC585 Practice for Inner and Outer Diameters of ThermalInsulation for Nominal Sizes of Pipe and TubingC835 Test Met
8、hod for Total Hemispherical Emittance ofSurfaces up to 1400CC1371 Test Method for Determination of Emittance ofMaterials Near Room Temperature Using Portable Emis-sometersC1423 Guide for Selecting Jacketing Materials for ThermalInsulationD3363 Test Method for Film Hardness by Pencil TestE84 Test Met
9、hod for Surface Burning Characteristics ofBuilding MaterialsF1249 Test Method for Water Vapor Transmission RateThrough Plastic Film and Sheeting Using a ModulatedInfrared Sensor2.2 ANSI Standard:4ANSI H35.2/H35.2(M) Dimensional Tolerances for Alumi-num Mill Products3. Terminology3.1 DefinitionsDefin
10、itions in Terminology C168 apply toterms used in this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 box ribaluminum sheet formed to have alternatingparallel grooves and ridges with a cross section approximatinga square wave3.2.2 cladding (as related to insulation jacketing)s
11、ynonymous with jacketing3.2.2.1 DiscussionThe three terms “jacketing”, “lagging”,and “cladding” are considered synonymous in most metaljacket related applications and geographies. However, in somecases in the power industry in North America the term“lagging” has a different meaning than “jacketing”
12、or “clad-ding” and refers specifically to a heavier gauge of jacketing.3.2.3 crevice corrosionLocalized corrosion of metal jack-eting surface at, or immediately adjacent to, an area that is1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct resp
13、onsibility of Subcommittee C16.40 onInsulation Systems.Current edition approved May 1, 2013. Published June 2013. Originallyapproved in 2010. Last previous edition approved in 2012 as C172912c. DOI:10.1520/C172913.2The boldface numbers in parentheses refer to a list of references at the end ofthis s
14、tandard.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute
15、 (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1shielded from full exposure to the environment because ofclose proximity between the metal and the surface of an
16、othermaterial.3.2.4 cross crimpedsynonymous with316 in. corrugated3.2.5 deep corrugatedaluminum sheet formed to havealternating parallel grooves and ridges with a cross sectionapproximating a sine wave3.2.6 finishthe texture of the aluminum surface3.2.7 gorejacketing for elbows, fittings, or other n
17、on-straight portions of the piping system made from a multitude ofsimilar overlapping pieces3.2.8 lagging (as related to insulation jacketing)synonymous with jacketing3.2.8.1 DiscussionThe three terms “jacketing”, “lagging”,and “cladding” are considered synonymous in most metaljacket related applica
18、tions and geographies. However, in somecases in the power industry in North America the term“lagging” has a different meaning than “jacketing” or “clad-ding” and refers specifically to a heavier gauge of jacketing.3.2.9 moisture retarder (moister barrier)a layer of plasticfilm or other material appl
19、ied to the inner side of metaljacketing to inhibit jacket corrosion by interfering with theformation of a galvanic cell between the dissimilar metals ofthe pipe and jacket or by preventing crevice corrosion3.2.9.1 DiscussionA moisture retarder is not an insulationsystem water vapor retarder and does
20、 not perform the samefunction.3.2.10 polykrafta multilayer composite film used as amoisture retarder on metal jacketing consisting of at least onelayer of minimum 40 lb kraft paper and one or more layers ofplastic film, usually polyethylene at a minimum thickness of1.5 mils.3.2.11 polysurlyna multil
21、ayer film used as a moistureretarder on metal jacketing consisting of at least one layer ofethylene/methacrylic acid copolymer and one or more layers ofother polymers, usually polyethylene.3.2.12 safety edgean edge of metal jacketing that hasbeen de-burred or rounded by a rolling operation3.2.13 saf
22、ety hema rounded edge of metal jacketing cre-ated by folding the edge of sheet jacketing completely backupon itself using a roll former or a brake.3.2.13.1 DiscussionThe fold is typically made toward theunderside of the jacketing so that the original edge is hiddenand the external appearance of the
23、jacketing is preserved.3.2.14 splice rollmetal jacketing sold in roll form wherethe package contains two separate pieces of metal jacketingrolled approximately end to end.3.2.14.1 DiscussionA splice roll occurs when the metalcoil being used to form the roll jacketing reaches its end beforethe requir
24、ed roll length is obtained.3.2.15 split rollsynonymous with splice roll.4. Significance and Use4.1 This specification is used to specify material by physicalproperty requirements that address the prerequisites in Sections6 to 10. The designer of an insulation system, after determiningthe system requ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17292013STANDARDSPECIFICATIONFORALUMINUMJACKETINGFORINSULATION 绝缘 护套 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-465670.html