ASTM C1719-2011(2017) Standard Test Method for Installed Precast Concrete Tanks and Accessories by the Negative Air Pressure (Vacuum) Test Prior to Backfill《回填前采用负风压(真空)试验测定已安装预制混凝.pdf
《ASTM C1719-2011(2017) Standard Test Method for Installed Precast Concrete Tanks and Accessories by the Negative Air Pressure (Vacuum) Test Prior to Backfill《回填前采用负风压(真空)试验测定已安装预制混凝.pdf》由会员分享,可在线阅读,更多相关《ASTM C1719-2011(2017) Standard Test Method for Installed Precast Concrete Tanks and Accessories by the Negative Air Pressure (Vacuum) Test Prior to Backfill《回填前采用负风压(真空)试验测定已安装预制混凝.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1719 11 (Reapproved 2017)Standard Test Method forInstalled Precast Concrete Tanks and Accessories by theNegative Air Pressure (Vacuum) Test Prior to Backfill1This standard is issued under the fixed designation C1719; the number immediately following the designation indicates the year o
2、foriginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for testing precastconc
3、rete tanks (and installed accessories) used for on-sitewastewater treatment, grease interception, grit/oil separation,water storage, or other applications requiring watertight con-struction and installation. This test method uses partial vacuumto demonstrate the integrity of the installed materials
4、and theconstruction processes.1.2 This test method is intended to be used to demonstratethe condition of the installed system (precast concrete tank andaccessories) prior to backfill.1.3 Testing of the system before backfill is necessary so asto preclude inadvertent structural overloading of the sys
5、temcomponents during the test.NOTE 1Vacuum test criteria presented in this test method are similarto those in general use. The test and criteria have been widely andsuccessfully used in testing manholes as specified in Test Method C1244.1.4 The values stated in inch-pound units are to be regardedas
6、standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of thi
7、s standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principl
8、es for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C822 Terminology Relating to Concrete Pipe and RelatedProductsC1227 Specification for Precast Con
9、crete Septic TanksC1244 Test Method for Concrete Sewer Manholes by theNegative Air Pressure (Vacuum) Test Prior to Backfill3. Terminology3.1 For definitions of terms relating to tanks, see Terminol-ogy C822.4. Summary of Test Method4.1 The tank shall be set in its installed position. Requiredaccesso
10、ries and pipes shall be installed. All openings and pipesentering the tank shall be plugged. A vacuum shall be drawnand vacuum retention over a specified time period is used todetermine the acceptability of the tank and installed accesso-ries.5. Significance and Use5.1 This is not a routine test. Th
11、e values recorded areapplicable only to the tank being tested and at the time oftesting. This test is intended only to demonstrate the sealingeffectiveness of the installed system. Structural design of thetank is defined or demonstrated within the scope of otherapplicable specifications and test met
12、hods, including Specifi-cation C1227.6. Equipment Required6.1 A vacuum device is required and shall be capable ofreliably drawing the required vacuum. Suitable vacuum de-vices include vane- and venturi-type pumps, vehicle vacuumsystems, and high-performance shop-style vacuum cleaners.6.2 A vacuum me
13、asuring device is required and shall be avacuum gauge, mercury manometer, or water manometeraccurate to 0.1 in. (2.5 mm) Hg 1.4 in. (35 mm) H2O. If a1This test method is under the jurisdiction of ASTM Committee C27 on PrecastConcrete Products and is the direct responsibility of Subcommittee C27.30 o
14、n Waterand Wastewater Containers.Current edition approved June 1, 2017. Published July 2017. Originally approvedin 2011. Last previous edition approved in 2011 as C1719 11. DOI: 10.1520/C171911R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service a
15、t serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accord
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC171920112017STANDARDTESTMETHODFORINSTALLEDPRECASTCONCRETETANKSANDACCESSORIESBYTHENEGATIVEAIRPRESSUREVACUUMTESTPRIORTOBACKFILL

链接地址:http://www.mydoc123.com/p-465641.html