ASTM C1708 C1708M-2013 Standard Test Methods for Self-leveling Mortars Containing Hydraulic Cements《含水凝水泥自流平沙浆的标准试验方法》.pdf
《ASTM C1708 C1708M-2013 Standard Test Methods for Self-leveling Mortars Containing Hydraulic Cements《含水凝水泥自流平沙浆的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1708 C1708M-2013 Standard Test Methods for Self-leveling Mortars Containing Hydraulic Cements《含水凝水泥自流平沙浆的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1708/C1708M 121C1708/C1708M 13Standard Test Methods forSelf-leveling Mortars Containing Hydraulic Cements1This standard is issued under the fixed designation C1708/C1708M; the number immediately following the designation indicates theyear of original adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEChanges were made editorially in October 2013.1. Scope Scope*1.1 These test methods are appropriate to evalua
3、te the performance of self-leveling mortars containing hydraulic cements thatare used to improve the levelness, smoothness, and flatness of existing floors. These materials may be used as an underlaymentto receive floor finishes, or as an overlayment to serve as the wear surface. The self-leveling m
4、ortars covered by these test methodsconsist of proprietary blends of hydraulic cements, along with fine aggregate, polymers, fillers, and other additives.1.2 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. The values statedin each system may n
5、ot be exact equivalents; therefore, each system shall be used independently of the other. Combining valuesfrom the two systems may result in non-conformance with the standard. Some values have only SI units because the inch-poundequivalents are not used in practice.1.3 This standard does not purport
6、 to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.(WarningFresh hydraulic cementitious mixtures are c
7、austic and may cause chemical burns to skin andtissue upon prolonged exposure.)22. Referenced Documents2.1 ASTM Standards:3C109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube Specimens)C125 Terminology Relating to Concrete and Concrete AggregatesC15
8、7/C157M Test Method for Length Change of Hardened Hydraulic-Cement Mortar and ConcreteC191 Test Methods for Time of Setting of Hydraulic Cement by Vicat NeedleC305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic ConsistencyC348 Test Method for Flexural Strength of Hy
9、draulic-Cement MortarsC490 Practice for Use of Apparatus for the Determination of Length Change of Hardened Cement Paste, Mortar, and ConcreteC670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction MaterialsC778 Specification for SandC928/C928M Specification for P
10、ackaged, Dry, Rapid-Hardening Cementitious Materials for Concrete RepairsC1005 Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing ofHydraulic CementsC1107/C1107M Specification for Packaged Dry, Hydraulic-Cement Grout (Nonshrink)E691 Practic
11、e for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Terminology3.1 DefinitionsFor definitions of terms used in these test methods, refer to Terminology C125.3.2 Definitions of Terms Specific to This Standard:3.2.1 flow, nof self-leveling mortars, the ability of a
12、freshly-mixed, self-leveling mortar to spread under its own weight.1 These test methods are under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregates and are the direct responsibility of Subcommittee C09.43on Packaged Dry Combined Materials.Current edition approved July 1, 201
13、2Dec. 15, 2013. Published September 2012January 2014. Orignally approved in 2011. Last previous edition approved in 20112012as C170811.12E01. DOI: 10.1520/C1708-12.10.1520/C1708-13.2 Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, Vol 04.02.3 F
14、or referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to pr
15、ovide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof th
16、e standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.2 healing, nof self-leveling mortars, the a
17、bility of a self-leveling mortar to return to its original state of levelness andsmoothness after being disturbed.a specified cut is introduced into the surface.3.2.2.1 DiscussionThe specified cut is described in 8.4.3.3.3.2.3 mortar, self-leveling, nmortar containing hydraulic cement that, in the f
18、resh state, exhibits flow sufficient to seekgravitational leveling.3.2.4 overlayment, nin flooring, a layer of material usually placed upon the sub-floor that provides a smooth, even surface tobe left exposed as the wear surface of the floor.3.2.5 time, healing, nof self-leveling mortars, the period
19、 of time from initial contact of a self-leveling mortar with mixingwater just prior to the time at which the self-leveling mortar no longer heals but instead leaves a visiblefrom the starting time untilthe moment when a specified cut leaves no observable indentation or ridge inon the surface after b
20、eing disturbed.setting.3.2.5.1 DiscussionThe specified cut is described in 8.4.3.3.3.2.6 time, starting, nof self-leveling mortars, the time when water is brought into contact with the dry ingredients of aself-leveling mortar.3.2.7 underlayment, nin flooring, a layer of material usually placed upon
21、the sub-floor that provides a smooth, even base forflooring.4. Significance and Use4.1 The test methods in this standard are used to evaluate freshly mixed properties such as the initial flow, flow retention, andhealing time as well as hardened properties such as compressive strength, setting time,
22、and flexural strength, of self-levelingmortars.4.2 Tests are conducted under standardized conditions for comparative purposes and results are not intended to be representativeof performance under field conditions.5. Standard Laboratory Conditions5.1 Unless otherwise specified, curing and testing of
23、specimens shall be conducted at standard laboratory conditions which aredefined as 23.0 6 2.0 C 73.5 6 3.5 F and the relative humidity of the laboratory shall be not less that 50 %. For optional testsat the manufacturers stated temperature extremes, the curing and testing temperatures must be within
24、 62.0 C 63.5 F of thestated extreme temperatures.6. Sampling6.1 Sample according to the Sampling section of Specification C1107/C1107M.7. Mixing7.1 Apparatus7.1.1 Use the mixer and scraper as specified in Practice C305. The standard batch size is 3000 g (See Note 1) of dry self-levelingmortar. Use a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1708C1708M2013STANDARDTESTMETHODSFORSELFLEVELINGMORTARSCONTAININGHYDRAULICCEMENTS 含水 水泥 自流 沙浆 标准

链接地址:http://www.mydoc123.com/p-465600.html