ASTM C1629 C1629M-2018 Standard Classification for Abuse-Resistant Nondecorated Interior Gypsum Panel Products and Fiber-Reinforced Cement Panels.pdf
《ASTM C1629 C1629M-2018 Standard Classification for Abuse-Resistant Nondecorated Interior Gypsum Panel Products and Fiber-Reinforced Cement Panels.pdf》由会员分享,可在线阅读,更多相关《ASTM C1629 C1629M-2018 Standard Classification for Abuse-Resistant Nondecorated Interior Gypsum Panel Products and Fiber-Reinforced Cement Panels.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1629/C1629M 15C1629/C1629M 18Standard Classification forAbuse-Resistant Nondecorated Interior Gypsum PanelProducts and Fiber-Reinforced Cement Panels1This standard is issued under the fixed designation C1629/C1629M; the number immediately following the designation indicates theyear of
2、original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This standard establishes classifications of abuse resista
3、nce based on the abrasion resistance and impact resistanceperformance of nondecorated interior gypsum panel products and fiber-reinforced cement panels (abuse resistant wall panels).1.1.1 This standard is a method of classifying gypsum panel product performance and is not intended to classify system
4、s forabuse resistance.1.2 The values stated in inch-pound and SI (metric) units are to be regarded separately as standard. Within the text, the SI unitsare shown in brackets. The values stated in each system shall be used independent of the other. Values from the two systems shallnot be combined.1.3
5、 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prio
6、r to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barri
7、ers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C11 Terminology Relating to Gypsum and Related Building Materials and SystemsC473 Test Methods for Physical Testing of Gypsum Panel ProductsC840 Specification for Application and Finishing of Gypsum BoardC1154 Terminology for No
8、n-Asbestos Fiber-Reinforced Cement ProductsD4977 Test Method for Granule Adhesion to Mineral Surfaced Roofing by AbrasionD5420 Test Method for Impact Resistance of Flat, Rigid Plastic Specimen by Means of a Striker Impacted by a Falling Weight(Gardner Impact)E695 Test Method of Measuring Relative Re
9、sistance of Wall, Floor, and Roof Construction to Impact Loading2.2 ISO Documents:ISO 6707-1 Building and Civil EngineeringVocabularyPart 1: General Terms3. Terminology3.1 Definitions of terms shall be in accordance with Terminologies C11 and C1154.3.2 Definitions of Terms Specific to This Standard:
10、3.2.1 failure (hard body impact), ntest result constituted by the penetration or deformation of the wall cavity by the impacthead establishing a residual deflection of the panel exceeding the nominal thickness of the test panel.3.2.2 structural failure (soft body impact), na test result constituted
11、by the penetration or deformation of the wall cavity bythe soft body impact bag establishing a residual deflection of any area on the test panel that exceeds the nominal thickness of thetest panel.1 This classification is under the jurisdiction of ASTM Committee C11 on Gypsum and Related Building Ma
12、terials and Systems and is the direct responsibility ofSubcommittee C11.01 on Specifications and Test Methods for Gypsum Products.Current edition approved June 1, 2015June 1, 2018. Published July 2015July 2018. Originally approved in 2005. Last previous edition approved in 20142015 asC1629/C1629M 14
13、a.C1629/C1629M 15. DOI: 10.1520/C1629_C1629M-15.10.1520/C1629_C1629M-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the AS
14、TM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consul
15、t prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, P
16、A 19428-2959. United States13.2.2.1 deformation, nchange of shape or dimension or both. ISO 6707-13.2.2.2 surface damage, npulverization of the core of the test panel at the point of impact, which is evidenced by cracking,creasing, or other visible damage short of failure as defined in 3.2.2.3.2.3 r
17、esidual deflection, npermanent deformation of a building element, component, or structure after removal of appliedforce.3.2.3.1 DiscussionAlso called permanent set or residual deformation.4. Significance and Use4.1 Each abuse/impact property of abuse resistant wall panels is divided into three class
18、ification levels. The three levels ofclassification are: Level I, Level II, and Level III, with Level I representing the lowest rating for any given property. The testmethods specified are utilized to establish the abuse-resistance classification of an abuse resistant wall panel. Each classification
19、level requires a minimum overall specified performance. Any classified abuse resistant wall panel can be used at a classificationlevel which is rated lower than the highest level qualified.5. Basis of Classification5.1 Abuse resistant wall panels are classified into one of three levels of abuse resi
20、stance based on minimum performance whentested in accordance with test methods that evaluate surface abrasion, indentation, soft body impact, and hard body impact asspecified in 6.1 6.4.5.2 Minimum requirements for each level are as shown in Tables 1-4.6. Test Methods6.1 Surface Abrasion TestThis te
21、st is conducted in accordance with Test Method D4977 using a total load of 25.0 lb 11.3 kg.The specimen is conditioned to constant weight at 70F 21C and 50 % relative humidity and subjected to 50 abrasion cycles.The abrasive motion on the specimen creates measurable surface wear or indentation which
22、 is measured to determine the level ofsurface abrasion resistance.NOTE 1It is especially important to prepare the apparatus and condition the brush as specified in Test Method D4977.6.2 Indentation TestThis test, conducted in accordance with Test Method D5420 (Gardner Impact), utilizes procedure GC,
23、with a 58-in. 15.9 mm hemispherical head and a 72 in.-lb 12.6 J impact energy. The depth of the indentation is measured todetermine the level of indentation resistance.6.3 Soft Body Impact TestThis test, conducted in accordance with Method E695, is performed with the use of the standardleather bag f
24、illed with steel pellets to a weight of 60.0 lb 27.2 kg and dropped through an angular distance until the specimenis impacted. The point of impact shall be midway between studs at the mid-height of the test panel.6.3.1 Apparatus:6.3.1.1 Wall AssemblyA single 4 by 8 ft 1200 by 2400 mm panel is mounte
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1629C1629M2018STANDARDCLASSIFICATIONFORABUSERESISTANTNONDECORATEDINTERIORGYPSUMPANELPRODUCTSANDFIBERREINFORCEDCEMENTPANELSPDF

链接地址:http://www.mydoc123.com/p-465358.html