ASTM C1303 C1303M-2011 Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation《预测闭孔绝缘泡沫的长期热电阻的标准试验方法》.pdf
《ASTM C1303 C1303M-2011 Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation《预测闭孔绝缘泡沫的长期热电阻的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1303 C1303M-2011 Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation《预测闭孔绝缘泡沫的长期热电阻的标准试验方法》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:C1303/C1303M10 Designation: C1303/C1303M 11Standard Test Method forPredicting Long-Term Thermal Resistance of Closed-CellFoam Insulation1This standard is issued under the fixed designation C1303/C1303M; the number immediately following the designation indicates theyear of original adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for predicting the long-term thermal r
3、esistance (LTTR) of unfaced or permeably facedrigid gas-filled closed-cell foam insulations by reducing the specimen thickness to accelerate aging under controlled laboratoryconditions (1-5) .2NOTE 1See Terminology, 3.2.1, for the meaning of the word aging within this standard.1.2 Rigid gas-filled c
4、losed-cell foam insulation includes all cellular plastic insulations manufactured with the intent to retain ablowing agent other than air.1.3 This test method is limited to unfaced or permeably faced, homogeneous materials. This method is applied to a wide rangeof rigid closed-cell foam insulation t
5、ypes, including but not limited to: extruded polystyrene, polyurethane, polyisocyanurate, andphenolic. This test method does not apply to impermeably faced rigid closed-cell foams or to rigid closed-cell bun stock foams.NOTE1See Note 7 2See Note 8 for more details regarding the applicability of this
6、 test method to rigid closed-cell bun stock foams.1.4 This test method utilizes referenced standard test procedures for measuring thermal resistance. Periodic measurements areperformed on specimens to observe the effects of aging. Specimens of reduced thickness (that is, thin slices) are used to sho
7、rtenthe time required for these observations. The results of these measurements are used to predict the long-term thermal resistanceof the material.1.5 The test method is given in two parts. The Prescriptive Method in Part A provides long-term thermal resistance values ona consistent basis that can
8、be used for a variety of purposes, including product evaluation, specifications, or product comparisons.The Research Method in part B provides a general relationship between thermal conductivity, age, and product thickness.1.5.1 To use the Prescriptive Method, the date of manufacture must be known,
9、which usually involves the cooperation of themanufacturer.1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining v
10、alues from thetwo systems may result in non-conformance with the standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine
11、 the applicability of regulatorylimitations prior to use.1.8 Table of Contents:SectionScope 1Reference Documents 2Terminology 3Summary of Test Method 4Significance and Use 5Part A: The Prescriptive Method 6Applicability 6.1Qualification Requirements 6.1.1Facing Permeability 6.1.2Apparatus 6.2Samplin
12、g 6.3Schedule 6.3.11This test method is under the jurisdiction of ASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.30 on ThermalMeasurement.Current edition approved JuneMarch 1, 2010.2011. Published July 2010.March 2011. Originally approved in 1995. Last
13、previous edition approved in 20092010 asC130309a.C1303 10. DOI: 10.1520/C1303_C1303M-101.2The boldface numbers in parentheses refer to the list of references at the end of this standard.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication
14、of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be consider
15、ed the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Representative Replicate Prod-uct Sheets6.3.2Replicate Test Specimen Sets 6.3.3Specimen Preparation 6.4Goal 6.4.1Schedule 6.4.2Specimen Extraction 6.4.3Slice Fla
16、tness 6.4.4Slice Thickness 6.4.5Stack Composition 6.4.6Storage Conditioning 6.5Test Procedure 6.6Thermal Resistance Measure-ment Schedule6.6.1Thermal Resistance Measure-ments6.6.2Product Density 6.6.3Calculations 6.7Part B: The Research Method 7Background 7.1TDSL Apparatus 7.2Sampling Schedule 7.3Sp
17、ecimen Preparation 7.4Storage Conditioning 7.5Test Procedure 7.6Calculations 7.7Reporting 8Reporting for Part A, the Pre-scriptive Method8.1Reporting for Part B, the Re-search Method8.2Precision and Bias 9Keywords 10Mandatory Information Qualifi-cationAnnexA1Specimen Preparation A1.1Homogeneity Qual
18、ification A1.2Aging Equivalence Test Proce-dureA1.3Alternate Product ThicknessQualificationA1.4Example Calculations A1.5Mandatory Information-Preparation of Test Specimens forSpray-Foam ProductsAnnexA2Effect Of TDSL Appen-dix X1History of the Standard Appen-dix X2Theory of Foam Aging Appen-dix X3Ref
19、erences2. Referenced Documents2.1 ASTM Standards:3C168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of theGuarded-Hot-Plate ApparatusC518 Test Method for Steady-State Thermal Transmission Properties by
20、 Means of the Heat Flow Meter ApparatusC578 Specification for Rigid, Cellular Polystyrene Thermal InsulationC591 Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal InsulationC1029 Specification for Spray-Applied Rigid Cellular Polyurethane Thermal InsulationC1045 Practice fo
21、r Calculating Thermal Transmission Properties Under Steady-State ConditionsC1126 Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal InsulationC1289 Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation BoardD1622 Test Method for Apparent Density of Rigid Cellular
22、 PlasticsD6226 Test Method for Open Cell Content of Rigid Cellular PlasticsE122 Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot orProcess3For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Custome
23、r Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.C1303/C1303M 1122.2 Other Standards:CAN/ULC S770 Standard Test Method for Determination of Long-Term Thermal Resistance of Closed-Cell Thermal Insulatio
24、nFoams42.3 ASTM Adjuncts:Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation53. Terminology3.1 DefinitionsFor definitions of terms and symbols used in this test method, refer to Terminology C168.3.2 Definitions of Terms Specific to This Standard:3.2.1 aging, vthe c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1303C1303M2011STANDARDTESTMETHODFORPREDICTINGLONGTERMTHERMALRESISTANCEOFCLOSEDCELLFOAMINSULATION

链接地址:http://www.mydoc123.com/p-464148.html