ASTM C1298-1995(2007) Standard Guide for Design and Construction of Brick Liners for Industrial Chimneys《工厂烟囱砖砌内衬的设计和施工的标准指南》.pdf
《ASTM C1298-1995(2007) Standard Guide for Design and Construction of Brick Liners for Industrial Chimneys《工厂烟囱砖砌内衬的设计和施工的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1298-1995(2007) Standard Guide for Design and Construction of Brick Liners for Industrial Chimneys《工厂烟囱砖砌内衬的设计和施工的标准指南》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1298 95 (Reapproved 2007)Standard Guide forDesign and Construction of Brick Liners for IndustrialChimneys1This standard is issued under the fixed designation C 1298; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers procedures for the design, construc-tion, and serviceability of brick liners for industri
3、al chimneys.The structural design criteria are applicable to vertical masonrycantilever structures supported only at their base, either by afoundation, a concrete pedestal, or by some means from theouter concrete shell. Excluded from direct consideration aresingle-wythe, sectional brick linings that
4、 are supported on aseries of corbels cast in the outer chimney shell.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with i
5、ts use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 395 Specification for Chemical-Resistant Resin MortarsC 466 Specific
6、ation for Chemically Setting Silicate andSilica Chemical-Resistant MortarsC 980 Specification for Industrial Chimney Lining BrickE 447 Test Methods for Compressive Strength of MasonryPrisms3E 111 Test Method for Youngs Modulus, Tangent Modulus,and Chord Modulus2.2 ACI Standard:30788 Practice for the
7、 Design and Construction of Cast-In-Place Reinforced Concrete Chimneys42.3 ASCE Standard:ASCE 7-88 Minimum Design Loads for Buildings andOther Structures (Formerly ANSI A58.1)52.4 Other Standard:1991 Uniform Building Code, International Conference ofBuilding Code Officials, California63. Terminology
8、3.1 Notations:a = brick dimension in radial direction (in.)b = brick dimension in tangential direction (in.)c = brick chamfer (in.)Ce= chimney deflection due to earthquake loads (in.)d = outside diameter of brick liner (in.)D = mean liner diameter at a given elevation (in.)Em= masonry modulus of ela
9、sticity as established by performing brick prismtest or by past experience, psifb= critical liner buckling stress, psifd= maximum vertical compressive stress due to dead load, psifde= maximum vertical compressive stress due to the combined effect ofearthquake and dead load, psifdw= maximum vertical
10、compressive stress due to the combined effect ofwind and dead load, psifm= average ultimate masonry compressive strength established by perform-ing brick prism test or by past experience, psifv= maximum shear stress due to wind or earthquake, psiF.S. = factor of safetyh = total liner height (ft)he=
11、height of liner above elevation being checked for buckling (ft)Le= liner deflection due to earthquake loads (in.)P = constructional out-of-plumbness of liner with respect to shell (in.)r = average mean radius of liner (ft)S = shell deflection due to sun effect (in.)T = liner deflection due to differ
12、ential temperature effects (in.)t = wall thickness (in.)v = coefficient of variation in brick prism testsW = shell deflection due to design wind loads (in.)a = coefficient of thermal expansion for brick liner (use 3.5 3 106unlessotherwise established) (in./in./F)4. Significance and Use4.1 History:4.
13、1.1 For many years, brick liners have been used with anexcellent record of performance. For the most part, however,the design and construction of brick liners has been based onpast industry practice due to the lack of available information1This guide is under the jurisdiction of ASTM Committee C15 o
14、n ManufacturedMasonry Units and is the direct responsibility of Subcommittee C15.05 on MasonryAssemblies.Current edition approved Dec. 1, 2007. Published January 2008. Originallyapproved in 1995. Last previous edition approved in 2001 as C 1298 95 (2001).2For referenced ASTM standards, visit the AST
15、M website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4Available from American Concrete Institute (ACI), P.O. Box 9094, FarmingtonHills, MI 48333-909
16、4, http:/www.aci-int.org.5Available from American Society of Civil Engineers (ASCE), 1801 AlexanderBell Dr., Reston, VA 20191, http:/www.asce.org.6Available from International Code Council (ICC), 5203 Leesburg Pike, Suite600, Falls Church, VA 22041-3401, http:/www.intlcode.org.1Copyright ASTM Intern
17、ational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.and knowledge of the physical properties of the brick andmortar, the thermal and seismic behavior of brick liners, andmany related characteristics that were not properly or accu-rately defined.4.1.2 The use
18、of scrubbers, which lower gas temperaturesand introduce highly corrosive condensates into the flue gassystem, requires many new design considerations. The effectthat scrubbers have on brick liners is an ongoing area of study,since a number of liners have experienced growth- anddeflection-related pro
19、blems which may be attributable, at leastin part, to nonuniform temperature and moisture conditionswithin the liners.4.2 PurposeThe recommendations contained herein rep-resent current industry practices and serve to define thepertinent considerations that should be followed in the designand construc
20、tion of brick chimney liners.5. Materials5.1 GeneralThe selection of suitable liner materials,those capable of resisting the environment to which they willbe exposed, should be based on an evaluation of the uniqueoperating conditions that exist in each application. Although itis not the intent to re
21、strict the applicability of this guide, andwhile other materials may be appropriate in some applications,the chemical-resistant brick and mortar standards set forth in5.2 and 5.3 define the type of materials used in the majority ofbrick liners that are specified, designed, and erected today. Allport
22、ions of this guide reflect test data, design requirements, andother practices as they relate to these materials. The provisionsof this guide should be carefully reviewed for applicability ifother materials are specified or used. Due to a greater knowl-edge of overall plant operation, material capabi
23、lities, and theflue gas environment, the owners technical representativeshould be responsible for selecting all liner materials.5.2 Brick:5.2.1 Unless the specific application precludes their use,brick conforming to the requirements of Specification C 980should be used. Specification C 980 covers so
24、lid kiln-firedbrick made of clay, shale, or mixtures thereof.5.2.2 Three types of brick are defined in SpecificationC 980: Types I, II, and III. By definition, the brick types vary,respectively, in decreasing degrees of absorption and acidsolubility. These bricks generally are resistant to all acids
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC129819952007STANDARDGUIDEFORDESIGNANDCONSTRUCTIONOFBRICKLINERSFORINDUSTRIALCHIMNEYS 工厂 烟囱 内衬 设计

链接地址:http://www.mydoc123.com/p-464138.html