ASTM C126-1999(2005) Standard Specification for Ceramic Glazed Structural Clay Facing Tile Facing Brick and Solid Masonry Units《上釉陶瓷结构粘土面砖、饰面瓷砖和实心砌块标准规范》.pdf
《ASTM C126-1999(2005) Standard Specification for Ceramic Glazed Structural Clay Facing Tile Facing Brick and Solid Masonry Units《上釉陶瓷结构粘土面砖、饰面瓷砖和实心砌块标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C126-1999(2005) Standard Specification for Ceramic Glazed Structural Clay Facing Tile Facing Brick and Solid Masonry Units《上釉陶瓷结构粘土面砖、饰面瓷砖和实心砌块标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 126 99 (Reapproved 2005)Standard Specification forCeramic Glazed Structural Clay Facing Tile, Facing Brick,and Solid Masonry Units1This standard is issued under the fixed designation C 126; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 Th
3、is specification covers structural clay load-bearingfacing tile and facing brick and other “solid masonry units”made from clay, shale, fire-clay, or mixtures thereof, with orwithout the addition of grog or other mixtures, having a finishconsisting of a ceramic glaze fused to the body at above1500F (
4、655C) making them inseparable, excluding naturalsalt-glazed ware. Two grades, based on permissible variation inface dimensions, and two types are covered, as follows:1.1.1 Grade S (select), for use with comparatively narrowmortar joints.1.1.2 Grade SS (select sized or ground edge), for use wherevari
5、ation of face dimension must be very small.1.1.3 Type I (single-faced units), for general use where onlyone finished face will be exposed.1.1.4 Type II (two-faced units), for use where two oppositefinished faces will be exposed.1.2 The property requirements of this specification apply atthe time of
6、purchase. The use of results from testing of brickand tile extracted from masonry structures for determiningconformance or nonconformance to the property requirements(Section 5) of this standard is beyond the scope of thisspecification.1.3 Brick and tile covered by this specification are manu-factur
7、ed from clay, shale, or similar naturally occurring sub-stances and subjected to a heat treatment at elevated tempera-tures (firing). The heat treatment must develop sufficient firedbond between the particulate constituents to provide thestrength requirements of this specification. (See firing and f
8、iredbond in Terminology C43.)1.4 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.5 The following precautionary caveat pertains only to
9、 thetest portion (Section 16) of this specification. This standarddoes not purport to address all of the safety concerns, if any,associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practicesand determine the applicability of regula
10、tory limitations priorto use.2. Referenced Documents2.1 ASTM Standards:2C43 Terminology of Structural Clay ProductsC67 Test Methods of Sampling and Testing Brick andStructural Clay TileE84 Test Method for Surface Burning Characteristics ofBuilding Materials2.2 National Fire Protection Association St
11、andard:3NFPA No. 255 Test for Surface Burning Characteristics ofBuilding Materials2.3 Underwriters Laboratories, Inc. Standard:4UL No. 723 Flammability Studies of Cellular Plastics andother Building Materials used for Interior Finishes2.4 International Conference of Building Offcials Stan-dard:5UBC
12、No. 8-1 Test Method for Fire Hazard Classification ofBuilding Material2.5 Government Standard:6Federal Standard Test No. 1413. Ordering Information3.1 Orders for material under this specification shall includethe following information:3.1.1 GradeWhen the grade is not specified, the require-ments for
13、 Grade S shall govern.1This specification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.02 on Clay Brick and Structural Clay Tile.Current edition approved May 15, 2005. Published June 2005. Originallyapproved in 1936.
14、 Last previous edition approved in 1999 as C 126 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Availabl
15、e from the National Fire Protection Association, 1 Batterymarch Park,Quincy, MA 02169.4Available from Underwriters Laboratories, Inc., 333 Pfingsten Rd., Northbrook,IL 60062.5Available from the International Conference of Building Officials, 5360 S.Workman Mill Rd., Whittier, CA 90601.6Available fro
16、m Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.2 TypeWhen the type is not specified, the require-ments for Type
17、 I shall govern.3.1.3 Sizes and Shapes The sizes and shapes shall bespecified in accordance with Section 9.3.1.4 Color and Texture of FinishThe color and texture ofthe finish shall be specified in accordance with Section 8.3.1.5 Back Surfaces Unless otherwise specified, smooth,scored, combed, or rou
18、ghened unglazed backs and smoothunselected glazed backs or a mixture thereof, are furnished.When plaster is to be applied, the back surface shall bespecified in accordance with Section 12.3.1.6 CoringUnless otherwise specified, either standardor special duty units as prescribed in Section 13 are fur
19、nished.3.1.7 OpacityWhere ceramic glazed units are not speci-fied as opaque, they need not meet the requirements for opacityprescribed in 7.2.3.1.8 Exterior Use Where ceramic glazed units are re-quired for exterior use, the manufacturers shall be consulted formaterial suitable for this purpose.NOTE
20、1The requirements included in this specification do not coverminimum criteria for durability of units exposed to exterior environments.4. Description of Units4.1 Units are multicored, hollow, or uncored, as follows:4.1.1 Solid Masonry Unit (multicored or uncored) is amasonry unit whose net cross-sec
21、tional area in every planeparallel to the bearing surface is 75 % or more of its grosscross-sectional area measured in the same plane.4.1.2 Hollow Masonry Unit is a masonry unit whose netcross-sectional area in any plane parallel to the bearing surfaceis less than 75 % of its gross cross-sectional a
22、rea measured inthe same plane.5. Compressive Strength5.1 The compressive strengths (based on gross area) of theunits shall be not less than the values prescribed in Table 1.6. Workmanship, Finish, and Appearance6.1 The body of the units shall be free of cracks or otherimperfections which would impai
23、r the strength or durability ofthe masonry.6.2 Unless otherwise agreed upon between the purchaserand the seller, a delivery of brick or tile shall not contain morethan 3 % brick or tile that are chipped, cracked or broken.6.3 The finished face (one face of stretcher units and thefinished faces of sh
24、apes) that will be exposed when in placeshall be covered with a ceramic glaze of uniform quality. Theglaze shall be free of chips, crazes, blisters, crawling, or otherimperfections detracting from the appearance of the finishedwall when viewed from a distance of 5 ft (1.52 m) at rightangles from the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12619992005STANDARDSPECIFICATIONFORCERAMICGLAZEDSTRUCTURALCLAYFACINGTILEFACINGBRICKANDSOLIDMASONRYUNITS

链接地址:http://www.mydoc123.com/p-463960.html