ASTM C118M-2011 Standard Specification for Concrete Pipe for Irrigation or Drainage (Metric)《灌溉或排水用混凝土管的标准规格(米制)》.pdf
《ASTM C118M-2011 Standard Specification for Concrete Pipe for Irrigation or Drainage (Metric)《灌溉或排水用混凝土管的标准规格(米制)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C118M-2011 Standard Specification for Concrete Pipe for Irrigation or Drainage (Metric)《灌溉或排水用混凝土管的标准规格(米制)》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C118M 11Standard Specification forConcrete Pipe for Irrigation or Drainage (Metric)1This standard is issued under the fixed designation C118M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers nonreinforced concrete pipe tobe used for the conveyance of irrigation water with workingpressures, includi
3、ng hydraulic transients, as shown in Table 1and for use in drainage.1.2 This specification is the SI counterpart of SpecificationC118.NOTE 1This specification is for manufacturing and purchase only anddoes not include requirements for bedding, backfill, installation, or fieldrepairs. The owner is ca
4、utioned that he must correlate field conditions withthe characteristics of the pipe specified and provide inspection duringinstallation.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC150 Specification for Portland CementC497M Test Methods for Concrete Pipe, Manh
5、ole Sections,or Tile MetricC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC822 Terminology Relating to Concrete Pipe and RelatedProductsC989 Specification for Slag Cement for Use in Concreteand MortarsC1116 S
6、pecification for Fiber-Reinforced Concrete andShotcrete3. Terminology3.1 DefinitionsFor definitions of terms relating to con-crete pipe, see Terminology C822.4. Classification4.1 Pipe manufactured according to this specification shallbe known as “ASTM Standard Concrete Irrigation Pipe,”“ASTM Standar
7、d Concrete Drainage Pipe,” or “ASTM Heavy-Duty Concrete Drainage Pipe.”5. Basis of Acceptance5.1 The acceptability of the pipe shall be determined by theresults of the tests prescribed in this specification, if and whenrequired and by inspection to determine whether the pipeconforms to this specific
8、ation as to design and freedom fromdefects.6. Materials6.1 ConcreteThe concrete shall consist of cementitiousmaterials, mineral aggregates, and water.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirementsfor portland cement of Specification C150 or shall be portlandblast-fur
9、nace slag cement, or slag-modified portland cement, orportland-pozzolan cement conforming to the requirements of1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.01 onNon-Reinforced Concrete Sewer, Drain and Irrig
10、ation Pipe.Current edition approved Sept. 1, 2011. Published October 2011. Originallyapproved in 1980. Last previous edition approved in 2005 as C118M 05a. DOI:10.1520/C0118M-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org.
11、For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.TABLE 1 Standard Dimensions, Working Pressure, and TestRequirements for Standard Concrete Irrigation PipeAInternalDesignatedDiameter, mmThicknessof Wall,T,mmWorkingPressure,BkPaMinimu
12、mInternalHydrostaticTest Pressure,kPaMinimumThree-Edge-Bearing Load,kN/linear m150 22 90 345 19.0200 25 90 345 19.5250 29 90 345 20.5300 32 75 310 22.0350 35 75 310 23.5375 38 75 310 24.0400 38 75 310 25.0450 44 75 310 26.5500 50 75 275 27.0525 54 75 275 27.5600 57 75 275 29.0AFor hydrostatic test r
13、equirements, refer to 10.5.BHigher working pressures are not prohibited up to a maximum of 120 kPa for150 through 200-mm diameters, 105 kPa for 250 through 300-mm diameters, and90 kPa for 350 through 600-mm diameters. In these cases, the strength of the pipeshall be increased to give a minimum inter
14、nal hydrostatic test pressure of at leastfour times the design working pressure when tested as specified in 10.5.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Specification C595, except that the pozzolan constituent in theType IP p
15、ortland-pozzolan cement shall be fly ash.6.2.2 Fly AshFly ash shall conform to the requirements ofSpecification C618, Class F or Class C.6.2.3 Ground Granulated Blast Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120of Specification C989.6.2.4 Allowable Combinations of
16、Cementitious MaterialsThe combination of cementitious materials used in the concreteshall be one of the following:6.2.4.1 Portland cement only,6.2.4.2 Portland blast furnace slag cement only,6.2.4.3 Slag modified portland cement only,6.2.4.4 Portland pozzolan cement only,6.2.4.5 A combination of por
17、tland cement and fly ash,6.2.4.6 A combination of portland cement and groundgranulated blast-furnace slag, or6.2.4.7 A combination of portland cement, fly ash (not toexceed 25 % of the total cementitious weight) and groundgranulated blast furnace slag (not to exceed 25 % of the totalcementitious wei
18、ght).6.3 AggregatesAggregates shall conform to SpecificationC33, except that the requirements for gradation shall not apply.6.4 Admixtures and BlendsOwner is not prohibited fromobtaining the record of mix design used.6.5 Synthetic FibersCollated fibrillated virgin polypro-pylene fibers are not prohi
19、bited in concrete pipe as a nonstruc-tural manufacturing material. Only Type III synthetic fibersdesigned and manufactured specifically for use in concrete andconforming to the requirements of Specification C1116 shall beaccepted.7. Design7.1 Design TablesDesign requirements shall be in accor-dance
20、with Table 1 for standard concrete irrigation pipe or withthe applicable part of Table 2 for concrete drainage pipe. Wallthicknesses used shall be not less than the values shown, exceptas affected by the tolerances herein specified and by theprovision for alternative design.7.2 Modified DesignManufa
21、cturers shall submit to theowner for approval prior to manufacture, wall thicknessesother than those shown in Table 1 or Table 2. Such pipe shallmeet all of the test and performance requirements specified bythe owner in accordance with Section 10.7.3 Laying LengthsUnless otherwise specified by theow
22、ner when calling for bids, maximum lengths of individualunits of drainage pipe shall not exceed 750 mm for sizes 100mm through 150 mm, or 900 mm for sizes 200 mm through375 mm, and 1200 mm for larger sizes.8. Joints8.1 The joints of both irrigation and drainage pipe shall beof such design and the en
23、ds of the concrete pipe sections soformed that the pipe can be laid together to make a continuousline of pipe compatible with the permissible variations given inSection 11.8.1.1 The joints of concrete drain tile shall conform to 8.1without the use of mortar or other jointing material and allowwater
24、to enter without permitting the entrance of deleteriousamounts of solids.9. Concrete Mixture9.1 The aggregates shall be sized, graded, proportioned, andthoroughly mixed with such proportions of cementitious ma-terials and water as will produce a homogeneous concretemixture of such quality that the p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC118M2011STANDARDSPECIFICATIONFORCONCRETEPIPEFORIRRIGATIONORDRAINAGEMETRIC 灌溉 排水 混凝土 标准 规格 米制 PDF

链接地址:http://www.mydoc123.com/p-463677.html