1、Designation: C118 15Standard Specification forConcrete Pipe for Irrigation or Drainage1This standard is issued under the fixed designation C118; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、 parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers nonreinforced concrete pipe tobe used for the conveyance of irrigation water with workingpressures, including hydrauli
3、c transients, as shown in Table 1and for use in drainage.1.2 A complete SI companion to Specification C118 hasbeen developedC118M; therefore, no SI equivalents arepresented in this specification.NOTE 1This specification is for manufacturing and purchase only anddoes not include requirements for bedd
4、ing, backfill, installation, or fieldrepairs. The owner is cautioned that he must correlate field conditions withthe characteristics of the pipe specified and provide inspection duringinstallation.2. Referenced Documents2.1 ASTM Standards:2C33/C33M Specification for Concrete AggregatesC150/C150M Spe
5、cification for Portland CementC260/C260M Specification for Air-Entraining Admixturesfor ConcreteC494/C494M Specification for Chemical Admixtures forConcreteC497 Test Methods for Concrete Pipe, Manhole Sections, orTileC595/C595M Specification for Blended Hydraulic CementsC618 Specification for Coal F
6、ly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC822 Terminology Relating to Concrete Pipe and RelatedProductsC989/C989M Specification for Slag Cement for Use inConcrete and MortarsC1017/C1017M Specification for Chemical Admixtures forUse in Producing Flowing ConcreteC1116/C1116M Speci
7、fication for Fiber-Reinforced ConcreteC1602/C1602M Specification for Mixing Water Used in theProduction of Hydraulic Cement Concrete3. Terminology3.1 DefinitionsFor definitions of terms relating to concretepipe, see Terminology C822.4. Classification4.1 Pipe manufactured according to this specificat
8、ion shallbe known as “ASTM Standard Concrete Irrigation Pipe,”“ASTM Standard Concrete Drainage Pipe,” or “ASTM Heavy-Duty Concrete Drainage Pipe.”5. Basis of Acceptance5.1 The acceptability of the pipe shall be determined by theresults of the tests prescribed in this specification, if and whenrequir
9、ed and by inspection to determine whether the pipeconforms to this specification as to design and freedom fromdefects.6. Materials6.1 ConcreteThe concrete shall consist of cementitiousmaterials, mineral aggregates, admixture, if used, and water.6.2 Cementitious Materials:6.2.1 CementCement shall con
10、form to the requirementsfor portland cement of Specification C150/C150M or shall beportland blast-furnace slag cement, portland-limestone cement,or portland-pozzolan cement conforming to the requirementsof Specification C595/C595M, except that the pozzolan con-stituent in the Type IP portland-pozzol
11、an cement shall be flyash.6.2.2 Fly AshFly ash shall conform to the requirements ofSpecification C618, Class F or Class C.6.2.3 Slag CementSlag cement shall conform to the re-quirements of Grade 100 or 120 of Specification C989/C989M.6.2.4 Allowable Combinations of Cementitious MaterialsThe combinat
12、ion of cementitious materials used in the concreteshall be one of the following:6.2.4.1 Portland cement only;6.2.4.2 Portland blast-furnace slag cement only;6.2.4.3 Portland-pozzolan cement only;6.2.4.4 Portland-limestone cement only;6.2.4.5 A combination of portland cement or portland-limestone cem
13、ent and fly ash;1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.01 onNon-Reinforced Concrete Sewer, Drain and Irrigation Pipe.Current edition approved Oct. 1, 2015. Published October 2015. Originallyapproved in
14、1935. Last previous edition approved in 2011 as C118 11. DOI:10.1520/C0118-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page on
15、the ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.2.4.6 A combination of portland cement or portland-limestone cement and slag cement;6.2.4.7 A combination of portland cement or portland-limestone cement, fly ash and
16、slag cement; or6.2.4.8 A combination of portland-pozzolan cement and flyash.6.3 AggregatesAggregates shall conform to the require-ments of Specification C33/C33M, except that the require-ments for gradation shall not apply.6.4 AdmixturesThe following admixtures and blends areallowable:6.4.1 Air-entr
17、aining admixture conforming to SpecificationC260/C260M.6.4.2 Chemical admixture conforming to SpecificationC494/C494M;6.4.3 Chemical admixture for use in producing flowingconcrete conforming to Specification C1017/C1017M; and6.4.4 Chemical admixture or blend approved by the owner.6.5 FibersSynthetic
18、 fibers and nonsynthetic fibers shall beallowed to be used, at the manufacturers option, in concretepipe as a nonstructural manufacturing material. Synthetic fibers(Type II and Type III) and nonsynthetic fiber (Type 1) designedand manufactured specifically for use in concrete and conform-ing to the
19、requirements of Specification C1116/C1116M shallbe accepted.6.6 WaterWater used in the production of concrete shallbe potable or nonpotable water that meets the requirements ofSpecification C1602/C1602M.7. Design7.1 Design TablesDesign requirements shall be in accor-dance with Table 1 for standard c
20、oncrete irrigation pipe or withthe applicable part of Table 2 for concrete drainage pipe. Wallthicknesses used shall be not less than the values shown, exceptas affected by the tolerances herein specified and by theprovision for alternative design.7.2 Modified DesignManufacturers shall submit to the
21、owner for approval prior to manufacture, wall thicknessesother than those shown in Table 1 or Table 2. Such pipe shallmeet all of the test and performance requirements specified bythe owner in accordance with Section 10.7.3 Laying LengthsUnless otherwise specified by theowner when calling for bids,
22、maximum lengths of individualunits of drainage pipe shall not exceed 30 in. for sizes 4 in.through 6 in., 36 in. for sizes 8 in. through 15 in., and 48 in. forlarger sizes.8. Joints8.1 The joints of both irrigation and drainage pipe shall beof such design and the ends of the concrete pipe sections s
23、oformed that the pipe can be laid together to make a continuousline of pipe compatible with the permissible variations given inSection 11.8.1.1 The joints of concrete drain tile shall conform to 8.1without the use of mortar or other jointing material and allowwater to enter without permitting the en
24、trance of deleteriousamounts of solids.9. Concrete Mixture9.1 The aggregates shall be sized, graded, proportioned, andthoroughly mixed with such proportions of cementitious ma-terials and water as will produce a homogeneous concretemixture of such quality that the pipe will conform to the testand de
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1182015STANDARDSPECIFICATIONFORCONCRETEPIPEFORIRRIGATIONORDRAINAGE 灌溉 或者 排水 混凝土 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-463645.html