《ASTM C1113 C1113M-2009 Standard Test Method for Thermal Conductivity of Refractories by Hot Wire (Platinum Resistance Thermometer Technique)《用热丝(铂阻尼式温度计技术)测定耐火制品的导热性的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1113 C1113M-2009 Standard Test Method for Thermal Conductivity of Refractories by Hot Wire (Platinum Resistance Thermometer Technique)《用热丝(铂阻尼式温度计技术)测定耐火制品的导热性的试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1113/C 1113M 09Standard Test Method forThermal Conductivity of Refractories by Hot Wire (PlatinumResistance Thermometer Technique)1This standard is issued under the fixed designation C 1113/C 1113M; the number immediately following the designation indicates theyear of original adoptio
2、n or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of thermalconductivity of non-car
3、bonacious, dielectric refractories.1.2 Applicable refractories include refractory brick, refrac-tory castables, plastic refractories, ramming mixes, powderedmaterials, granular materials, and refractory fibers.1.3 Thermal conductivity k-values can be determined fromroom temperature to 1500C 2732F, o
4、r the maximumservice limit of the refractory, or to the temperature at whichthe refractory is no longer dielectric.1.4 This test method is applicable to refractories withk-values less than 15 W/mK 100 Btuin./hft2F.1.5 In general it is difficult to make accurate measurementsof anisotropic materials,
5、particularly those containing fibers,and the use of this test method for such materials should beagreed between the parties concerned.1.6 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. Thevalues stated in each system may not be exact equivale
6、nts;therefore, each system shall be used independently of the other.Combining values from the two systems may result in non-conformance with the standard.1.7 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this sta
7、ndard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 134 Test Methods for Size, Dimensional Measurements,and Bulk Density of Refractory Brick and InsulatingFirebrickC 201 Test Meth
8、od for Thermal Conductivity of Refracto-riesC 865 Practice for Firing Refractory Concrete SpecimensE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Standard:DIS*8894-2 Refractory Materials - Determination of Ther-mal Conductivity up to 1250C of
9、 Dense and InsulatingRefractory Products According to the Hot Wire ParallelMethod33. Terminology3.1 Symbols:3.1.1 RThot wire resistance at any temperature, ohms.3.1.2 R0hot wire resistance at 0C 32F (from an icebath), ohms.3.1.3 Lhot wire length, cm.3.1.4 Tsample test temperature, C.3.1.5 Vaverage v
10、oltage drop across hot wire, volts.3.1.6 Vsaverage voltage drop across standard resistor,volts.3.1.7 Rsaverage resistance of standard resistor, ohms.3.1.8 Iaverage current through hot wire (Vs/Rs), amperes.3.1.9 Qaverage power input to hot wire (I*V*100/L)during test, watts/m.3.1.10 ttime, min.3.1.1
11、1 Bslope of linear region in RTvs. ln(t) plot.3.1.12 kthermal conductivity, W/mK.3.1.13 a, b, ccoefficients of a second degree polynomialequation relating hot wire resistance and temperature.3.1.14 V, I, and Q are preferably measured in the linearregion of the RTversus ln(t) plot for maximum data ac
12、curacy.4. Summary of Test Method4.1 A constant electrical current is applied to a pure plati-num wire placed between two brick. The rate at which the wireheats is dependent upon how rapidly heat flows from the wireinto the constant temperature mass of the refractory brick. Therate of temperature inc
13、rease of the platinum wire is accurately1This test method is under the jurisdiction of ASTM Committee C08 onRefractories and is the direct responsibility of Subcommittee C08.02 on ThermalProperties.Current edition approved March 1, 2009. Published March 2009. Originallyapproved in 1990. Last previou
14、s edition approved in 2004 as C 111399 (2004).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from
15、 American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.determined by measuring its increase in resistance in the sameway a plati
16、num resistance thermometer is used. A Fourierequation is used to calculate the k-value based on the rate oftemperature increase of the wire and power input.45. Significance and Use5.1 The k-values determined at one or more temperaturescan be used for ranking products in relative order of theirtherma
17、l conductivities.5.2 Estimates of heat flow, interface temperatures, and coldface temperatures of single, and multi-component linings canbe calculated using k-values obtained over a wide temperaturerange.5.3 The k-values determined are “at temperature” measure-ments rather than “mean temperature” me
18、asurements. Thus, awide range of temperatures can be measured, and the resultsare not averaged over the large thermal gradient inherent inwater-cooled calorimeters.5.4 The k-values measured are the combination of thek-values for the width and thickness of the sample, as the heatflow from the hot wir
19、e is in both of those directions. Thewater-cooled calorimeter measures k-value in one direction,through the sample thickness.5.5 The test method used should be specified when report-ing k-values, as the results obtained may vary with the type oftest method that is used. Data obtained by the hot wire
20、 methodare typically 10 to 30 % higher than data obtained by the watercalorimeter method given in Test Method C 201.6. Apparatus6.1 A block diagram of a suggested test apparatus is shownin Fig. 1. Details of the equipment are as follows:6.1.1 Furnace, with a heating chamber capable of support-ing tw
21、o 228-mm 9-in. straight brick. The furnace temperaturemay be controlled with a set point controller adjusted manuallybetween test temperatures, with a programmable controller, orwith the computer. If a programmable controller is used, andthe hot wire power is applied by computer, the furnacetemperat
22、ure program must be synchronized with the computerprogram used to collect the test data. The furnace temperatureshould be accurate to 6 5C 9F and controlled to within a 61C 1.8F precision such that the temperature variation withtime is minimized. Temperature stability measurements are notrequired by
23、 this test method because small temperature varia-tions with time are difficult to measure and dependent onthermocouple placement (in air, a protection tube, or in thesample). However, if sample temperature measurements areaveraged during a 30 minute period after furnace equilibration(prior to a hot
24、 wire test), the maximum-minimum differenceshould preferably be less than 1C 1.8F. In addition, if alinear regression analysis is done on the average temperaturevs. time data, the rate of temperature change should preferablybe less than 0.05C 0.09F/min. Four holes with aluminaprotection tubes shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1113C1113M2009STANDARDTESTMETHODFORTHERMALCONDUCTIVITYOFREFRACTORIESBYHOTWIREPLATINUMRESISTANCETHERMOMETERTECHNIQUE

链接地址:http://www.mydoc123.com/p-463418.html