ASTM B78-1990(2013) Standard Test Method of Accelerated Life of Iron-Chromium-Aluminum Alloys for Electrical Heating《电加热用铁铬铝合金的加速寿命的标准试验方法》.pdf
《ASTM B78-1990(2013) Standard Test Method of Accelerated Life of Iron-Chromium-Aluminum Alloys for Electrical Heating《电加热用铁铬铝合金的加速寿命的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B78-1990(2013) Standard Test Method of Accelerated Life of Iron-Chromium-Aluminum Alloys for Electrical Heating《电加热用铁铬铝合金的加速寿命的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B78 90 (Reapproved 2013)Standard Test Method ofAccelerated Life of Iron-Chromium-Aluminum Alloys forElectrical Heating1This standard is issued under the fixed designation B78; the number immediately following the designation indicates the year of originaladoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the resis-tance to oxidation of iron-chromium-aluminum
3、electrical heat-ing alloys at elevated temperatures under intermittent heatingusing a constant-temperature cycle test. This test is used forinternal comparative purposes only.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconv
4、ersions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to become familiarwith all hazards including those
5、identified in the appropriateMaterial Safety Data Sheet (MSDS) for this product/materialas provided by the manufacturer, to establish appropriatesafety and health practices, and determine the applicability ofregulatory limitations prior to use.2. Significance and Use2.1 This test method is used by p
6、roducers of electricalheating alloys to measure the cyclic oxidation resistance ofthese alloys.2.2 Because of the effect of environment, design and use,the life values obtained from this test method may not correlatewith that of an appliance or industrial heating unit.3. Test Panel3.1 Size and Locat
7、ionThe dimensions of the test panelshall be similar to those shown in Fig. 1. The test panel shall belocated in a position free from drafts of air.3.1.1 The enclosure shall fit tightly on the panel and theglass slide shall fit snugly to prevent leakage of air at this pointduring the operation of the
8、 test, as even a slight draft of air incontact with the specimen will cause excessive variation inlength of life. A screen of 40 wire mesh, 0.010-in. (0.025 mm)wire diameter, market grade, may be used as a cover over theindividual stations.3.2 TerminalsThe two terminals shall be spaced 2 in.(50.8 mm
9、) apart, center to center and shall be so positioned thatthe wire specimen when secured therein shall be in a U-shapedpattern as described in Section 5. The specimen terminaljunctions shall be 3 in. (76.2 mm) lower than the plane of thetop of the enclosure.4. Apparatus4.1 The apparatus shall be simi
10、lar to the requirementsspecified in 4.2 to 4.8, inclusive, and shall be connected asshown in Fig. 2.4.2 Power SupplyThe transformer or motor generator setshall be capable of delivering a controlled voltage of from 10to 35 V to the circuit. It shall have a continuous currentcapacity of at least 20 A/
11、specimen.4.3 Voltage ControlThe automatic voltage control shall becapable of maintaining across the bus bars a constant voltagewithin 60.5 %.NOTE 1It has been found impossible to make accurate tests withoutvoltage control, as changes in line voltage are sufficient to causeconsiderable variation in t
12、he results obtained (see Annex A1).4.4 Variable TransformerThe variable transformer shallbe capable of adjusting the voltage across the specimen towithin approximately 0.25 % of any desired value within theworking range and shall have a continuous current rating ofapproximately 25 A.NOTE 2A variable
13、 transformer having a working range of adjustabil-ity from approximately 0 to 20 V, provides for testing wires within aconsiderable range of size and resistivity.4.5 Ammeter and VoltmeterThe ammeter and voltmetershall have an accuracy of 1 % of normal test deflection(approximately 15 A and 15 V resp
14、ectively). For alternatingcurrent the range shall be such as to give a reading above thelower fifth of the scale range. The ammeter has appreciableresistance. A compensating resistance shall be cut into thecircuit to replace the resistance of the ammeter so that theover-all resistance of the circuit
15、 is not changed. This resistanceshall be inserted in series with the contact of the upper switchshown in Fig. 2.1This test method is under the jurisdiction of ASTM Committee B02 onNonferrous Metals and Alloys and is the direct responsibility of SubcommitteeB02.10 on Thermostat Metals and Electrical
16、Resistance Heating Materials.Current edition approved May 1, 2013. Published May 2013. Originallyapproved in 1959. Last previous edition approved in 2007 as B78 90 (2007). DOI:10.1520/B0078-90R13.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unit
17、ed States14.6 Optical Pyrometer or Infrared Thermometer The opticalsystem shall be such as to provide a magnification of at leastfour diameters. This may be accomplished by means of aspecial lens or combination of two standard lenses in theobjective to provide a short focal length and the desiredmag
18、nification (see AnnexA1). These instruments must have anaccuracy of 610F (5.5C) and UBS traceability.NOTE 3It is highly important that the temperatures of the testspecimen be adjusted as accurately as possible, as small variations intemperature result in considerable variation in length of life. Opt
19、icalpyrometer or infrared pycnometer makes it possible to determine thetemperature at any particular point on the wire, and with the arrangementdescribed, the temperature of a comparatively small wire may be takenquite readily.4.7 InterrupterSome form of apparatus shall be used as aninterrupter to o
20、pen and close the circuit.4.8 Apparatus for Recording Time of BurnoutIf no appa-ratus is available for recording the time of burnout, arrange-ments shall be made for hourly observations for burnouts.5. Test Specimen5.1 The test specimen shall be 0.0254 in. (0.645 mm) indiameter. The length of the wi
21、re selected for test shall be suchas to give a test length of approximately 10 in. (254 mm).5.2 The test specimen shall be representative with regard tothe surface of the average of the coil or spool of wire which hasbeen selected for test. Particular care shall be taken to see thatthe specimen sele
22、cted is free from kinks. This precaution isnecessary, since a kink, even though later removed may causeburnout at that point.Metric Equivalentsin. mm12 12.75532 131.0714 184.22112 54622 55952 132164 1626FIG. 1 Test PanelB78 90 (2013)2NOTE 4It is also very desirable to select and keep as a references
23、tandard for comparison, a spool or coil of wire that is uniform in crosssection from one end to the other. Tests may then be made at any time onthe reference standard, and if conditions have changed they will be notedby the length of life of the standard. Comparisons between tests made atdifferent t
24、imes on the standards and other wires may be correlated in thismanner (see Annex A1).6. Mounting Specimen6.1 A straight length of the specimen shall be shaped into a“U” pattern, 10 in. (254 mm) of which shall be mountedbetween the terminals described in 2.2. The “U” pattern shallconsist of two paral
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB7819902013STANDARDTESTMETHODOFACCELERATEDLIFEOFIRONCHROMIUMALUMINUMALLOYSFORELECTRICALHEATING 加热

链接地址:http://www.mydoc123.com/p-462252.html