1、Designation: B 214 07Standard Test Method forSieve Analysis of Metal Powders1This standard is issued under the fixed designation B 214; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthe
2、ses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the dry sieve analysis of metalpowders or mixed
3、 powders, using sieves with openings rangingfrom 45 to 1000 micrometers.1.2 This test method is based on a particular type ofmechanical sieve shaker (see 5.2). Other types of sieve shakersare also available, but their precision and reproducibility havenot been determined.1.3 The values stated in SI
4、units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health
5、practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B 212 Test Method for Apparent Density of Free-FlowingMetal Powders Using the Hall Flowmeter FunnelB 215 Practices for Sampling Metal PowdersB 243 Terminology of Powder Metall
6、urgyB 329 Test Method for Apparent Density of Metal Powdersand Compounds Using the Scott VolumeterB 417 Test Method for Apparent Density of Non-Free-Flowing Metal Powders Using the Carney FunnelB 703 Test Method for Apparent Density of Powders UsingArnold MeterE11 Specification for Wire Cloth and Si
7、eves for TestingPurposesE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 1638 Terminology Relating to Sieve Analysis2.2 MPIF Standard:MPIF 05 Determination of Sieve Analysis of Metal Pow-ders33. Terminology3.1 DefinitionsUseful definitions of terms r
8、elating topowder metallurgy are found in B 243 and those relating tosieve analysis are found in E 1638.4. Significance and Use4.1 The particle size distribution of a metal powder affectsits behavior in P/M processing and other applications of thesematerials. The test method may be part of the purcha
9、seagreement between powder supplier and user, or it may be aninternal quality control test for either.5. Apparatus5.1 SievesSelect a set of standard sieves from the tableentitled, “Nominal Dimensions, Permissible Variations forWire Cloth of Standard Test Sieves (U.S.A.) Standard Sieves,”of Specifica
10、tion E11, or the equivalent Tyler standard sieves.The sieves shall be 200 mm (8 in.) in diameter and either 25 or50 mm (1 or 2 in.) in depth, and fitted with bronze, brass,stainless steel, or other suitable wire cloth. The U.S. sievesgiven in the table entitled, “U.S. Standard Series Test Sievesand
11、Equivalent Tyler Standard Sieves,” of this test methodshall conform to Specification E11. If Tyler standard sieves aresubstituted, they shall conform to the permissible variationsgiven in the table entitled, “Nominal Dimensions, PermissibleVariations for Wire Cloth of Standard Test Sieves (U.S.A.)St
12、andard Sieves” of Specification E11.NOTE 1The new U.S. Series standard sieves, adopted in 1970, are thepreferred sieves to use. The old U.S. Series standard sieves and equivalentsieves manufactured by other companies, such as Tyler, may also be usedif the new U.S. Series is not available. Care shoul
13、d be taken to make surethat sieve opening sizes are correct when performing standardizationwork.5.2 Sieve Shaker A mechanically operated, single eccen-tric sieve shaker shall be used that imparts to the set of sievesa rotary motion and a tapping action of uniform speed. The1This test method is under
14、 the jurisdiction of ASTM Committee B09 on MetalPowders and Metal Powder Products and is the direct responsibility of Subcom-mittee B09.02 on Base Metal Powders.Current edition approved Jan. 1, 2007. Published January 2007. Originallyapproved in 1946. Last previous edition approved in 1999 as B 214
15、99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Metal Powder Industries Federation (MPIF),
16、 105 College RoadEast, Princeton, NJ 08540, http:/www.mpif.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.number of rotations per minute shall be between 270 and 300.The number of taps per minute shall be between 140 and 160.The
17、 hold down arm of the sieve shaker shall be fitted with ashock absorbing plug to receive the impact of the tappingdevice. The entire apparatus shall be rigidly mounted bybolting to a solid foundation, preferably of concrete.NOTE 2Use of a sound proof enclosure is recommended.5.3 BalanceA balance hav
18、ing a capacity of at least 150 gand a sensitivity of 0.01 g.6. Test Specimen6.1 The size of the test specimen shall be 90 to 110 g for anymetal powder having an apparent density greater than or equalto 1.50 g/cm3when determined in accordance with TestMethod B 212, B 329, B 417,orB 703.Aspecimen of 4
19、0 to 60g shall be used when the apparent density of the powder is lessthan 1.50 g/cm3. The test specimen should be obtained inaccordance with Practices B 215.7. Procedure7.1 Examine the sieves to make sure that they are notdamaged and are clean.7.2 Assemble the group of sieves selected in consecutiv
20、eorder by the size of their openings, with the coarsest sieve atthe top, the assembly being completed by a solid collecting panbelow the bottom sieve. Place the test specimen on the topsieve and close this sieve with a solid cover. Then fasten thesieve assembly securely in the sieve shaker and opera
21、te themachine for a period of 15 minutes.NOTE 3For some materials, for example brittle and friable materials,the 15 minutes may be too long. Sieving time may be adjusted for suchmaterials, and the actual time used should be reported along with the testdata.7.3 Remove the screened fractions from the
22、nest of sievesby removing the coarsest sieve from the nest, gently tapping itscontents to one side and pouring them upon a glazed paper.Brush any material adhering to the bottom surface of the sieveand the lower frame with a soft brush into the next finer sieve.Tap the sieve just removed upside down
23、, on the papercontaining the portion that had been retained on it, and brushthe back side of the sieve with the flat side of the brush so asto dislodge any particles that may have been wedged in thescreen openings, by pushing to the upper side of the screen.Weigh this fraction to the nearest 0.1 g a
24、nd remove it from thebalance. Repeat this process for each sieve in the nest. Removethe fraction collected in the pan and weigh. The sum of themasses of all the fractions shall be not less than 99 % of themass of the test specimen.Add the difference between this sumand the mass of the test specimen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB2142007STANDARDTESTMETHODFORSIEVEANALYSISOFMETALPOWDERS 金属粉末 筛分 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-460631.html