1、Designation: A460 11 (Reapproved 2016)Standard Specification forCopper-Clad Steel Wire Strand1This standard is issued under the fixed designation A460; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A nu
2、mber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers copper-clad steel wire strandcomposed of a number of round steel, copper-clad wires, foruse as guys, messengers
3、, span wires, and for similar purposeswhere electrical conductance is not a requirement.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standa
4、rd.2. Referenced Documents2.1 ASTM Standards:2A902 Terminology Relating to Metallic Coated Steel Prod-ucts3. Terminology3.1 For definitions of terms used in this specification seeTerminology A902.4. Classification4.1 The strand is classified by the minimum breakingstrength and number of wires in the
5、 strand as stated in Table 1.5. Ordering Information5.1 Orders for material under this specification shall includethe following information:5.1.1 Quantity of strand in feet.5.1.2 Breaking strength and number of wires in strand (4.1and Table 1).5.1.3 Package size of coils or reels from Table 2.5.1.4
6、ASTM designation and year of issue.6. Materials and Manufacture6.1 Each wire in the strand shall be composed of a steel coremade from steel produced by any commercially-acceptedsteel-making process, with a substantially uniform and con-tinuous copper cladding thoroughly bonded to it throughout.The t
7、hickness and adherence of the copper cladding on thefinished wire shall comply with the requirements prescribed inthis specification.6.2 Each wire in the strand shall be of such quality that,when drawn to the size specified in Table 1 and whenfabricated into strand, the finished copper-clad steel wi
8、re strandshall have the properties and characteristics prescribed in thisspecification.7. Stranding7.1 The strand shall consist of either 3 or 7 wires and, unlessotherwise specified, shall have a left lay with a uniform pitch.In 3-wire strand, the pitch shall be not less than 12 nor morethan 20 time
9、s the nominal diameter of the strand. In 7-wirestrand, the pitch shall be not less than 10 nor more than 16times the nominal diameter of the strand. A left lay is definedas a counter-clockwise twist away from the observer lookingalong the axis of the strand. All wires shall be stranded withuniform t
10、ension.7.2 All wires in the strand shall lie naturally in their truepositions in the completed strand, and when the strand is cut,the ends shall remain in position or be readily replaced by handand then remain in position. This may be accomplished by anymeans or process, such as preforming, post for
11、ming, or formsetting.8. Joints and Splices8.1 Joints or splices may be made prior to final wire drawingin individual finished wires composing the strand, providedthat such joints or splices have protection from corrosionequivalent to that of the copper-clad wire itself and that they donot decrease t
12、he strength of the finished strand below theminimum breaking strength shown in Table 1. A joint or spliceshall be not closer than 50 ft (15.2 m) to any other wire jointor splice in the strand.8.2 The finished strand shall not be joined or spliced as aunit, unless specifically permitted by the purcha
13、ser.9. Thickness of Copper Cladding9.1 The minimum thickness of the copper cladding at anypoint around the circumference of the wires taken from thefinished strand shall be not less than 8 % of the wire radius.1This specification is under the jurisdiction of ASTM Committee A05 onMetallic-Coated Iron
14、 and Steel Products and is the direct responsibility of subcom-mittee A05.12 on Wire Specifications.Current edition approved Nov. 1, 2016. Published November 2016. Originallyapproved in 1961. Last previous edition approved in 2011 as A460 - 11. DOI:10.1520/A0460-11R16.2For referenced ASTM standards,
15、 visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 1942
16、8-2959. United States19.2 The copper thickness shall be determined by either ofthe following:9.2.1 By direct measurements of cross sections of the wires,the ends of the specimens having been ground smooth,polished, and etched before being measured microscopically,or9.2.2 By means of a suitable elect
17、rical indicating instrumentoperating on the permeameter principle.10. Sampling10.1 For the purpose of inspecting the strand, tests shall bemade on representative samples. For lots of 10 000 lb (4536kg) or less, two samples shall be taken from separate reels orcoils in the lot, except that only one s
18、ample shall be requiredwhere the total length of the strand is 5000 ft (1524 m) or less.For lots over 10 000 lb (4536 kg) one sample from each 10 000lb (4536 kg) or fraction thereof shall be taken, but theminimum number of samples shall be three.11. Breaking Strength11.1 The breaking strength of the
19、 finished strand shall be notless than that specified in Table 1.11.2 When the breaking strength is below the minimumspecified, the cause of which may have been due to slipping ofthe specimen in the jaws of the testing machine, breakingwithin the jaws or within 1 in. (25.4 mm) of the jaws, or theimp
20、roper socketing of a specimen, the results of the test shallbe disregarded and another sample from the same coil or reelshall be tested.12. Elongation12.1 The elongation shall be not less than 1.5 % and shall bemeasured on a gage length of not less than 24 in. (610 mm) offinished strand which does n
21、ot contain wire joints or splices.Elongation shall be determined by measurements made be-tween the jaws of the testing machine or by an extensometer atthe option of the manufacturer, unless otherwise agreed upon atthe time of purchase.12.2 When the elongation is so determined, the gage lengthshall b
22、e the distance between the jaws of the testing machinewhen a load equal to 10 % of the minimum breaking strengthshall have been applied, and the final length shall be thedistance between the jaws at the time of fracture of any wire.The fracture shall be between the jaws of the testing machineand not
23、 closer than 1 in. (25.4 mm) to either jaw, otherwise thetest shall be disregarded.12.3 When used, the extensometer shall be attached to thetest specimen at a tension load equal to 10 % of minimumbreaking strength. The elongation shall be observed whileapplying a tension load to the specimen, and th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA46020112016STANDARDSPECIFICATIONFORCOPPERCLADSTEELWIRESTRAND 钢丝绳 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-458400.html