ASTM A341 A341M-2016 Standard Test Method for Direct Current Magnetic Properties of Soft Magnetic Materials Using D-C Permeameters and the Point by Point (Ballistic) Test Methods《使.pdf
《ASTM A341 A341M-2016 Standard Test Method for Direct Current Magnetic Properties of Soft Magnetic Materials Using D-C Permeameters and the Point by Point (Ballistic) Test Methods《使.pdf》由会员分享,可在线阅读,更多相关《ASTM A341 A341M-2016 Standard Test Method for Direct Current Magnetic Properties of Soft Magnetic Materials Using D-C Permeameters and the Point by Point (Ballistic) Test Methods《使.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A341/A341M 16Standard Test Method forDirect Current Magnetic Properties of Soft MagneticMaterials Using D-C Permeameters and the Point by Point(Ballistic) Test Methods1This standard is issued under the fixed designation A341/A341M; the number immediately following the designation indica
2、tes the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of t
3、he U.S. Department of Defense.1. Scope1.1 This test method provides dc permeameter tests for thebasic magnetic properties of soft magnetic materials in theform of bars, rods, wire, or strip specimens which may be cut,machined, or ground from cast, compacted, sintered, forged,extruded, rolled, or oth
4、er fabricated materials. It includes testsfor determination of the normal induction under symmetricallycyclically magnetized (SCM) conditions and the hysteresisloop (B-H loop) taken under conditions of rapidly changing orsteep wavefront reversals of the direct current magnetic fieldstrength. This me
5、thod has been historically referred to as theballistic test method. For testing hard or permanent magnetmaterials, Test Method A977/A977M shall be used.1.2 This test method shall be used in conjunction withPractice A34/A34M.1.3 This test method covers a range of magnetic fieldstrength in the specime
6、n from about 0.05 Oe 4 A/m up toabove 5000 Oe 400 kA/m through the use of severalpermeameters. The separate permeameters cover this testregion in several overlapping ranges.1.4 Normal induction and hysteresis properties may bedetermined over the magnetic flux density range from essen-tially zero to
7、the saturation induction for most materials.1.5 Recommendations of the useful magnetic field strengthrange for each of the permeameters are shown in Table 1.2Permeameters particularly well suited for general testing ofsoft magnetic materials are shown in boldface. Also, seeSections 3 and 4 for gener
8、al limitations relative to the use ofpermeameters.1.6 The symbols and abbreviated definitions used in this testmethod appear with Fig. 1 and in appropriate sections of thisdocument. For the official definitions, see Terminology A340.Note that the term magnetic flux density used in this documentis sy
9、nonymous with the term magnetic induction.1.7 WarningMercury has been designated by EPA andmany state agencies as a hazardous material that can causecentral nervous system, kidney, and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken w
10、hen handling mercury andmercury-containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAs website(http:/www.epa.gov/mercury/faq.htm ) for additional informa-tion. Users should be aware that selling mercury or mercury-containing products, or both, in your
11、 state may be prohibited bystate law.1.8 The values and equations stated in customary (cgs-emuand inch-pound) or SI units are to be regarded separately asstandard. Within this standard, SI units are shown in bracketsexcept for the sections concerning calculations where there areseparate sections for
12、 the respective unit systems. The valuesstated in each system may not be exact equivalents; therefore,each system shall be used independently of the other. Combin-ing values from the two systems may result in nonconformancewith this standard.1.9 This standard does not purport to address all of thesa
13、fety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3A34/A34M Practice for Sampling
14、 and Procurement Testing1This test method is under the jurisdiction of ASTM Committee A06 onMagnetic Properties and is the direct responsibility of Subcommittee A06.01 on TestMethods.Current edition approved May 1, 2016. Published May 2016. Originallyapproved in 1969. Last previous edition approved
15、in 2011 as A341/A341M 00(2011)1. DOI: 10.1520/A0341_A0341M-16.2The boldface numbers in parentheses refer to a list of references at the end ofthis standard.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of AST
16、MStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1of Magnetic MaterialsA340 Terminology of Symbols and Definitions Relating toMagnetic Testin
17、gA596/A596M Test Method for Direct-Current MagneticProperties of Materials Using the Ballistic Method andRing SpecimensA977/A977M Test Method for Magnetic Properties of High-Coercivity Permanent Magnet Materials Using Hyster-esigraphs2.2 IEC Standard:Publication 60404-4, Ed. 2.2 Magnetic Materials P
18、art 4:Methods of Measurement of D.C. Magnetic Properties ofTABLE 1 PermeametersPermeameterUseful Magnetic Field Strength RangeAH MeasuringDeviceBReluctanceCompensationMagnetizing CoilSurroundsSpecimenReferencesDOe kA/mBabbit 40/1000 3.2/80 I, HC yes yes (1,2)Burroughs 0.1/300 0.008/24 I yes yes (1,3
19、,4,5)Fahy SimplexC0.1/300 0.008/24 HC no no (1,4,5,6,7)Fahy SimplexSuper H adapterC100/2500 8/200 HC no no (1,3)Full range 0.05/1400 0.004/112 HC yes yes (1,8)High H 100/5000 8/400 FC yes no (1,5,7,9)Iliovici 0.5/500 0.04/400 I, HC yes yes (4,10,11)IEC Type A 0.1/2500 0.008/200 HC, HP no yes IEC 604
20、04-4IEC Type B 0.1/630 0.008/50 RCC no no IEC 60404-4Isthmus 100/20 000+ 8/1600+ HC, HP no no (1,4,12,13)MH 0.1/300 0.008/24 FC yes yes (1,6,14)NPL 0.5/2500 0.04/200 I, HC yes yes (15)Saturation 100/4000 8/320 HC no yes (5,16,17)AAlthough the permeameters are capable of being used at the lower end o
21、f the measurement range, the measurement accuracy is reduced.BImagnetizing current; HCfixed H coil; FCflip coil; HPHall probe; RCC Rogowski-Chattock coil.CFahy permeameters require a standard of known magnetic properties for calibration of the H coil.DThe boldface numbers in parentheses refer to a l
22、ist of references at the end of this standard.NOTE 1A1Multirange ammeter (main current)A2Multirange ammeter (hysteresis current)BMagnetic flux density test position for Switch S3FElectronic FluxmeterHMagnetic field strength test position for Switch S3N1Magnetizing coilN2Magnetic flux sensing (B) coi
23、lN3Magnetic field strength (H) sensing coilR1Main current control rheostatR2Hysteresis current control rheostatS1Reversing switch for magnetizing currentS2Shunting switch for hysteresis current control rheostatS3Fluxmeter selector switchSPSpecimenFIG. 1 Basic Circuit Using PermeameterA341/A341M 162I
24、ron and Steel, IEC, 1995 PlusAmendments 1 in 2000 and2 in 200842.3 Other Documents:NIST Circular No. 74, pg. 2695NIST Scientific Paper 117, SPBTA53. Significance and Use3.1 Permeameters require the use of yokes to complete themagnetic circuit and are therefore inherently less accurate thanring test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA341A341M2016STANDARDTESTMETHODFORDIRECTCURRENTMAGNETICPROPERTIESOFSOFTMAGNETICMATERIALSUSINGDCPERMEAMETERSANDTHEPOINTBYPOINTBALLISTICTESTMETHODS

链接地址:http://www.mydoc123.com/p-458092.html