《ARMY UFGS-23 00 00-2010 AIR SUPPLY DISTRIBUTION VENTILATION AND EXHAUST SYSTEMS.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-23 00 00-2010 AIR SUPPLY DISTRIBUTION VENTILATION AND EXHAUST SYSTEMS.pdf(76页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-23 00 00 (August 2010)-Preparing Activity: USACE SupersedingUFGS-23 00 00 (November 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING
2、SECTION 23 00 00AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS08/10PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.2.1 Mechanical Equipment Identification1.2.1.1 Charts1.2.1.2 Diagrams1.2.2 Service Labeling1.2.3 Color Coding1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Prevention of Corro
3、sion1.4.2 Asbestos Prohibition1.4.3 Ozone Depleting Substances Used as Refrigerants1.4.4 Use of Ozone Depleting Substances, Other than Refrigerants1.4.5 Detail Drawings1.4.6 Test Procedures1.4.7 Sustainable Design Certification1.5 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 STANDARD PRODUCTS2.
4、2 STANDARD PRODUCTS2.3 IDENTIFICATION PLATES2.4 EQUIPMENT GUARDS AND ACCESS2.5 ELECTRICAL WORK2.6 ANCHOR BOLTS2.7 SEISMIC ANCHORAGE2.8 PAINTING2.9 INDOOR AIR QUALITY2.10 DUCT SYSTEMS2.10.1 Metal Ductwork2.10.1.1 Metallic Flexible Duct2.10.1.2 Insulated Nonmetallic Flexible Duct Runouts2.10.1.3 Gener
5、al Service Duct ConnectorsSECTION 23 00 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.10.1.4 High Temperature Service Duct Connections2.10.1.5 Aluminum Ducts2.10.1.6 Copper Sheets2.10.1.7 Corrosion Resisting (Stainless) Steel Sheets2.10.
6、2 Duct Access Doors2.10.3 Fire Dampers2.10.4 Manual Balancing Dampers2.10.5 Manual Balancing Dampers2.10.5.1 Square or Rectangular Dampers2.10.5.2 Round Dampers2.10.6 Automatic Balancing Dampers2.10.7 Automatic Smoke-Fire Dampers2.10.8 Automatic Smoke Dampers2.10.9 Air Supply And Exhaust Air Dampers
7、2.10.10 Air Deflectors and Branch Connections2.10.11 Plenums and Casings for Field-Fabricated Units2.10.11.1 Plenum and Casings2.10.11.2 Casing2.10.11.3 Access Doors2.10.11.4 Factory-Fabricated Insulated Sheet Metal Panels2.10.11.5 Duct Liner2.10.12 Sound Attenuation Equipment2.10.13 Diffusers, Regi
8、sters, and Grilles2.10.13.1 Diffusers2.10.13.2 Perforated Plate Diffusers2.10.13.3 Linear Diffusers2.10.13.4 Security Ceiling Diffusers2.10.13.5 Registers and Grilles2.10.13.6 Registers2.10.13.7 Security Supply Air Registers Except in Cells2.10.13.8 Security Return and Other Air Registers Except in
9、Cells2.10.13.9 Security Supply Air Registers in Cells2.10.13.10 Security Return and Other Type Air Registers in Cells2.10.14 Louvers2.10.15 Air Vents, Penthouses, and Goosenecks2.10.16 Bird Screens and Frames2.10.17 Radon Exhaust Ductwork2.11 AIR SYSTEMS EQUIPMENT2.11.1 Fans2.11.1.1 Centrifugal Fans
10、2.11.1.2 In-Line Centrifugal Fans2.11.1.3 Axial Flow Fans2.11.1.4 Panel Type Power Wall Ventilators2.11.1.5 Centrifugal Type Power Wall Ventilators2.11.1.6 Centrifugal Type Power Roof Ventilators2.11.1.7 Propeller Type Power Roof Ventilators2.11.1.8 Air-Curtain Fans2.11.1.9 Ceiling Exhaust Fans2.11.
11、2 Coils2.11.2.1 Direct-Expansion Coils2.11.2.2 Water Coils2.11.2.3 Steam Heating Coils2.11.2.4 Steam Preheat (Nonfreeze) Coils2.11.2.5 Electric Heating Coil2.11.2.6 Eliminators2.11.2.7 Sprayed Coil Dehumidifiers2.11.2.8 Corrosion Protection for Coastal Installations2.11.3 Air Filters2.11.3.1 Extende
12、d Surface Pleated Panel FiltersSECTION 23 00 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.11.3.2 Extended Surface Nonsupported Pocket Filters2.11.3.3 Cartridge Type Filters2.11.3.4 Sectional Cleanable Filters2.11.3.5 Replaceable Media F
13、ilters2.11.3.6 Automatic Renewable Media Filters2.11.3.7 Electrostatic Filters2.11.3.8 High-Efficiency Particulate Air (HEPA) Filters2.11.3.9 Holding Frames2.11.3.10 Filter Gauges2.12 AIR HANDLING UNITS2.12.1 Field-Fabricated Air Handling Units2.12.2 Factory-Fabricated Air Handling Units2.12.2.1 Cas
14、ings2.12.2.2 Heating and Cooling Coils2.12.2.3 Air Filters2.12.2.4 Fans2.12.2.5 Access Sections and Filter/Mixing Boxes2.12.2.6 Diffuser Sections2.13 TERMINAL UNITS2.13.1 Room Fan-Coil Units2.13.1.1 Enclosures2.13.1.2 Fans2.13.1.3 Coils2.13.1.4 Drain Pans2.13.1.5 Manually Operated Outside Air Damper
15、s2.13.1.6 Filters2.13.1.7 Motors2.13.2 Coil Induction Units2.13.2.1 Enclosures2.13.2.2 Air Plenums2.13.2.3 Coils2.13.2.4 Screens2.13.2.5 Drain Pan2.13.3 Variable Air Volume (VAV) and Dual Duct Terminal Units2.13.3.1 Constant Volume, Single Duct Terminal Units2.13.3.2 Variable Volume, Single Duct Ter
16、minal Units2.13.3.3 Variable Volume, Single Duct, Fan-Powered Terminal Units2.13.3.4 Dual Duct Terminal Units2.13.3.5 Ceiling Induction Terminal Units2.13.3.6 Series Fan Powered Variable Air Volume (VAV) Terminals2.13.3.7 Reheat Units2.13.4 Unit Ventilators2.13.4.1 Enclosures2.13.4.2 Electric Resist
17、ance Heating Elements2.13.4.3 Fans2.13.4.4 Coils2.13.4.5 Drain Pans2.13.4.6 Filters2.13.4.7 Dampers2.13.4.8 Motors2.13.4.9 Outside Air Intakes2.14 ENERGY RECOVERY DEVICES2.14.1 Rotary Wheel2.14.2 Run-Around-Coil2.14.3 Heat Pipe2.14.4 Desiccant Wheel2.14.5 Plate Heat Exchanger2.15 FACTORY PAINTING2.1
18、6 SUPPLEMENTAL COMPONENTS/SERVICESSECTION 23 00 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.16.1 Chilled, Condenser, or Dual Service Water Piping2.16.2 Refrigerant Piping2.16.3 Water or Steam Heating System Accessories2.16.4 Condensate
19、 Drain Lines2.16.5 Backflow Preventers2.16.6 Insulation2.16.7 ControlsPART 3 EXECUTION3.1 EXAMINATION3.2 INSTALLATION3.2.1 Condensate Drain Lines3.2.2 Equipment and Installation3.2.3 Access Panels3.2.4 Flexible Duct3.2.5 Metal Ductwork3.2.5.1 Underground Ductwork3.2.5.2 Radon Exhaust Ductwork3.2.5.3
20、 Light Duty Corrosive Exhaust Ductwork3.2.6 FRP Ductwork3.2.7 Kitchen Exhaust Ductwork3.2.7.1 Ducts Conveying Smoke and Grease Laden Vapors3.2.7.2 Exposed Ductwork3.2.7.3 Concealed Ducts Conveying Moisture Laden Air3.2.8 Acoustical Duct Lining3.2.9 Dust Control3.2.10 Insulation3.2.11 Duct Test Holes
21、3.2.12 Power Roof Ventilator Mounting3.2.13 Power Transmission Components Adjustment3.3 EQUIPMENT PADS3.4 CUTTING AND PATCHING3.5 CLEANING3.6 PENETRATIONS3.7 FIELD PAINTING OF MECHANICAL EQUIPMENT3.7.1 Finish Painting3.7.2 Color Coding Scheme for Locating Hidden Utility Components3.8 IDENTIFICATION
22、SYSTEMS3.9 DUCTWORK LEAK TEST3.10 DUCTWORK LEAK TESTS3.11 DAMPER ACCEPTANCE TEST3.12 TESTING, ADJUSTING, AND BALANCING3.13 PERFORMANCE TESTS3.14 CLEANING AND ADJUSTING3.15 OPERATION AND MAINTENANCE3.15.1 Operation and Maintenance Manuals3.15.2 Operation And Maintenance Training- End of Section Table
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS2300002010AIRSUPPLYDISTRIBUTIONVENTILATIONANDEXHAUSTSYSTEMSPDF

链接地址:http://www.mydoc123.com/p-449645.html