1、 INCH - POUND MIL - PRF - 49471/3A(CR) 30 November 2000 Superseding MIL - PRF - 49471/3(ER) 2 June 1995 PERFORMANCE SPECIFICATION SHEET BATTERY, NON - RECHARGEABLE, HIGH PERFORMANCE, BA - X590/U This specification is appr oved for use within the Communications Electronics Command, Department of the
2、Army, and is available for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product herein shall consist of this specificatio n and MIL -PRF - 49471(CR). Figure 1. Battery dimensions and terminal markings . AMSC N/A 1 of 5 FSC 6135 DISTRIBUTION STA
3、TEMENT A . Approved for public release; distribution is unlimited. Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL - PRF - 49471/3A(CR) 2 NOTES : 1. All dimensions are in inch
4、es. 2. Tolerances , unless otherwise specified, are - 0.063, +0.000. 3. The battery terminal shall consist of a miniature circular battery connector, Dwg SC - C -179492, except as noted herein. 4. Connector socket body configuration shall accept two (2) each 0.156 inch min imum diameter guideposts a
5、s shown. Depth of cavity shall be 0.657 inch minimum. 5. The socket shall be supported and mounted so that the top surface of the socket shall not protrude above the adjacent outside surface of the jacket and shall not be mor e than 0.0625 inch below adjacent outside of the jacket when used initiall
6、y, during, and after subsequent insertions of the mating plug during testing. REQUIREMENTS : Dimensions and configuration: See Figure 1. Maximum voltage: 33 volts in 24 volt mode 16.5 volts in 12 volt mode Terminals: Six (6) hole socket type with no obstruction of any holes (see notes 3 and 5). Weig
7、ht (maximum): 3.5 pounds (1588 grams). Cut - off voltage for capacity: 20.00 volts in 24 volt mode 10.00 volts in 12 volt mo de Charge protection: Applicable. State of Charge Indicator: Applicable Battery short circuit test: Applicable. High temperature protection: Applicable. Complete discharge dev
8、ice: Applicable. Capacity tests: When the battery is tested in acc ordance with the methods of examination and tests of this specification, the minimum capacity test requirements shall be as specified below: Copyright Communications - Electronics Command Provided by IHS under license with CRAINot fo
9、r ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL - PRF - 49471/3A(CR) 3 Capacity Test * Minimum Capacity Requirements in Hours to 20.00 volts in Series, 10.00 volts in Parallel I & IP 3.4 L & LP 2.2 H & HP 5.6 HT & HTP 5.4 LT & LTP 2.0 IT & ITP 3.0 LR1 48.0 * NOTE: Sa
10、mple batteries that are to be assigned to a capacity test (except for the LR1) shall be equally divided between the designated capacity test and the ca pacity test ending in P (e.g. I and IP). The odd battery, if present, is assigned to parallel discharge capacity test. For the capacity tests that d
11、o not have the Ps, the batterys legs shall be discharged in series. For the capacity tests that have the Ps, the batterys legs shall be discharged in parallel. Initial voltage delay: During the I, H, HT, and IT discharge tests of the two (2) 12 volt sections connected in series under the designated
12、loads, initial voltage below the 20.00 volt minimum volt age cannot exceed a 5.0 second duration. During L and LT discharge tests initial voltage below 20.00 volts cannot exceed a 60 second duration. During the IP, HP, HTP, and ITP discharge tests of the two (2) 12 volt sections connected in paralle
13、l under the designated loads, initial voltage below the 10.00 volt minimum voltage cannot exceed a 5.0 second duration. During LP and LTP discharge tests initial voltage below 10.00 volts cannot exceed a 60 second duration. Connector: The connector configuration a nd operating temperature range requ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF494713A2000BATTERYNONRECHARGEABLEHIGHPERFORMANCEBAX590U 不可 充电 性能 电池 BAX590UPDF

链接地址:http://www.mydoc123.com/p-447397.html