ARMY MIL-P-63332-1980 PERISCOPES TANK M44A1E1 AND M44A2E1 11834842《M44A1E1和M44A2E1式坦克潜望镜 11834842》.pdf
《ARMY MIL-P-63332-1980 PERISCOPES TANK M44A1E1 AND M44A2E1 11834842《M44A1E1和M44A2E1式坦克潜望镜 11834842》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-P-63332-1980 PERISCOPES TANK M44A1E1 AND M44A2E1 11834842《M44A1E1和M44A2E1式坦克潜望镜 11834842》.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、% -_ 4. t MIL-P-b3332 12 777770b 03Y475 5 m - 5/3 743 MIL-P -63 33 2 ( AR) 15 February 1980 MILITARY SPECIFICATION PERISCOPES, TANK: M44AlE1 AND M44A2E1, 11834842 This specification is approved for use by the U.S. Army Armament Research and Development Camnand and is available for use by all Departm
2、ents and Agen- cies of the Department of Defense. 1. SCOPE 1.1 This specification covers the performance requirements, related quality assurance provisions, and packaging data for the Periscopes: M44AlEl and M44A2E1. power passive (low light level) sighting system The periscopes are equipped with a
3、reticle projector which projects the image of a reticle pattern into the sighting system. The periscopes provide a unity-power viewing system and a nine 2. APPLICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on date of invitation for bids or request for proposals, form a part of
4、 this specification to the extent specified herein. SPEC IF1 CATIONS Mil i tar y MIL -F -1 39 2 6 MIL -P - 142 3 2 MIL-1-4560 7 MIL-1-55340 STANDARDS Mil it ar y MIL-STD-105 MIL -STD- 1 O9 MIL-STD- 150 MIL-STD-202 MIL-STD-810 Fire Control Material: the Manufacture and Inspection of Parts , Equipment
5、 and Tools for Army Material, Packaging and Packing of Inspection Equipment, Acquisition and Disposition of Image Intensifier Tube Assembly, 25MM General Specification Governing Sampling Procedures and Tables for Inspection by Quality Assurance Terms and Definitions Photographic Lens es Test Methods
6、 for Electronic and Electrical Cmponent Environmental Test Methods At tributes Parts Beneficial commenta (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, US Army Armament Research and Development Command,
7、 Attn. DRDAR-QA, Dover, New Jersey 07801 by using the self-addressed Standardization Document Improvement PrcJposal (DD Form n26) appearingat the f his document or by letter. FSC 1249 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-b3332 12 m 7
8、797906 03Liq7b 7 m MIL-P-63332 (AR) DRAWINGS US Army Armament Research and Development Command (ARRADCOM) F10542204 Head Assembly 10558203 See para 3.16.1 and 3.16.2 11834841 See para 3.16.1 and 3.16.2 11 834833 See para 3.16.1 and 3.16.2 11 834842 Periscope, Tank: M44AlE1 and M44A2E1 F8565556 Press
9、ure Tester-Two Station F 11 7381 78 F11738179 F 11 7381 84 F 11 834835 Mount Assembly F11746430 Cable Assembly Gage - Interchangeability - Maximum Gage - Interchangeabi 1 i ty - Minimum Fixture - Interchangeability - Presure Testing PACKAGING DATA SHEETS PS 11834842-1 Packaging of Periscope: M44AlE1
10、 PS 11834842-2 Packaging of Periscope: M44A2E1 (Copies of specifications, standards, drawings and packaging data sheets required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting off i c er. ) 3. R EQU IR E
11、MENTS 3.1 Fabrication. The periscope shall be manufactured in accordance with the applicable drawing pertaining thereto (see 2.1). 3.2 Image intensifier tube, The image intsensifier tube shall conform to MIL-1-55340 (see 3.11.1). 3.3 Temperature conditions. Except as specified in 3.6 and 3.7 the fol
12、lowing requirements shall be met at a temperature between +600 and +90F. 3.4 General specification. The requirements of MIL-F-13926 listed below shall be met wherever applicable. a. Order of precedence. b. Dimensions and tolerances. c. Inorganic protective surface finishes. d. Part identification an
13、d marking. e. Sol der i ng el ec tr i cal connecti on s. 3.5 Workmanship, The workmanship requirements of MIL-F-13926 shall be met. The exterior protective surface finishes shall be free of voids which may affect their protective qualities or appearance. Optical surfaces shall be free of scratches a
14、nd blemishes which may affect their optical qualities or appear an ce. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-63332 i12 W 7979906 03LiALi77 7 m MIL-P-63332( AR) 3.6 Extreme storage temperatures. There shall be no evidence of physical
15、 failure such as glass breakage and bonding or casting failure due to storage - - to temperatures ranging from-800 to +1600F. 3.7 Extreme operating temperature. The periscope shall meet the applic- able requirements of 3.12.1 and 3.12.2 while exposed to and thermally stabi- lized at -650 and +1500F.
16、 Y 3.8 I- Vibration. This requirement shall be met with: a. The periscope assembled to its mount assembly. b, The image tube, and the reticle projector lamp energized using c. A line of sight established prior to vibration. d. The clear filter positioned in the optical train. 6.5 +.25 volts dc. The
17、periscope shall be vibrated successively along three (3) mutually perpen- dicular axes, Vibration shall be a simple harmonic motion, the fresuency varying either linearly or logarithmically from 5 to 55 to 5 CPS in five minute cycles for a total of 15 minutes along each of the axes. The amplitude of
18、 vibration shall be maintained constant at 1/64 inch (1/32 inch total excur- sion). The vibration test shall not cause: e. Failure or flicker of light emission from the reticle projector f. Evidence of physical failure during and subsequent to vibration. g. The established line of sight to deviate m
19、ore than 0.30 mil lamp, and image tube during vibration. subsequent to vibration. 3.9 Dielectric strength. This requirement shall be met with the image -.- tube and the reticle projector lamp renoved from their receptacles. Insula- tion resistance between ungrounded circuits, isolated circuits, and
20、castings shall be not less than 10 megohms at a potential of 100 Vdc. 3.10 Optical characteristics with image tube removed. Unless otherwise -I- -.-.- specified the requirements 3.10.1 through 3.10.6 inclusive shall be met with: a. The image tube removed from the periscope. b. The periscope assembly
21、 to its mount assembly c. The clear filter positioned in the optical train. 3.10.1 Contrast transfer. The contrast transfer for vertical lines and for horizontal linesshall be not less than the values specified in 3.10.1.1 and 3.10.1.2. 3.10.1.1 Objective system. The following values (for the axis s
22、pecified) shall be met with 28700 ;r 1000 Kelvin (K) radiance, modulated at the spa- cial frequency (angular spacing) indicated, incident to the entrance window and the contrast values obtained at the objective system focal plane. On axis is defined as the geometric axis of Sleeve Assy 10542215. 3 P
23、rovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-b3332 12 m 477770b 0348478 O m MIL -P-6 3 3 3 2 ( AR ) Off axis is defined as displacement, conforming to the value specified, from on axis. ANGULAR SPACING (in line ,pairs/milliradian) a. On axis.
24、 -_CI. - - O. 58 1.732 3.70 b. Off axis 0.3 inch. O. 58 1.732 3.70 CONTRAST TRANSFER Vertical lines Horizontal li= - .95 .91 .84 .93 .88 .78 .95 .91 .84 .93 .88 .78 3.10.1.2 Eyepiece and erecting system. The following values (for the -_l_-pl_l_-_l_. axis specified) shall be met with 28700 + 1000 Kel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILP633321980PERISCOPESTANKM44A1E1ANDM44A2E111834842M44A1E1 M44A2E1 坦克 潜望镜 11834842 PDF

链接地址:http://www.mydoc123.com/p-446800.html