ARMY MIL-H-48671-1988 HOLSTER HIP M12《M12手枪皮套 热等静压机》.pdf
《ARMY MIL-H-48671-1988 HOLSTER HIP M12《M12手枪皮套 热等静压机》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-H-48671-1988 HOLSTER HIP M12《M12手枪皮套 热等静压机》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-H.- 4 8 6 7 1 2 February 1988 (AR) t distribution is unlimited. 7 . THIS DOCUMENT CONTAINS I PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-48671 (AR) MILITARY MIL-STD- 10 5 -Sampling Procedures and Tables for MIL-STD-109 -Quality A
2、ssurance Terms and Definitions. MIL-STD-13 0 -Identification Marking of U.S. Military 2.1.2 Other Government documents, drawings and publications. Inspection by Attributes. Property. The following other Government documents, drawings and publications form a part of this specification to the extent s
3、secified herein. Unless otherwise specified, the issues shall be those listed in effect on the date of solicitation. DRAWINGS U.S. ARMY ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER (ARDEC) 9388057 Holster, Hip, M12 SP 193 8 80 57 Special Packaging Instructions for Holster, Hip, M12 (Copies
4、of specifications, standards, drawings, publications and other Government documents required by contractors in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting activity.) 2.1.3 Order of precedence. a In the event of a c
5、onflict between the text of this specification and the references cited herein, (except for associated detail specifications, specification sheets or MS standards) specificat;ion shall take precedence . Nothing in this specification, however, shall supersede applicable laws and regulations unless a
6、specific exemption has been obtained. the text of this 3. REQUIREMENTS 3:1 First article. When specified in the contract or purchase order, a sample shall be subjected to first article inspection in accordance with the technical provisions herein (see 4.4 and 6.2) . 3.2 Materials and construction. H
7、olsters and parts shall conform to the materials, dimensions, conditions and construction requirements specified herein, and on Drawing 9388057 and drawings applicable thereto, and shall be in accordance with the applicable mater ia1 and construct ion provisions of MIL-W-13855 . c 2 , Provided by IH
8、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-Li673 30 7779706 0323306 3 MIL-H-48671 (AR) 3.2.1 Stitches, seams and stitchings. All stitches, seams o and stitchings shall conform to FED-STD-751, type 301 and 304. 3.2.1.1 Repairs of type 301 stitching. Repa
9、irs of type 301 stitching shall be as follows: a. Thread breaks or bobbin run-outs which occur during stitching shall be repaired by restarting the stitching a minimum of one half inch in back of the stitching end. b. Thread breaks and skipped stitches shall be repaired by overstitching. The stitchi
10、ng shall start a minimum of one inch in back of the defective area, continue over the defective area and onto the existing stitching a minimum of one inch beyond the 4 defective area. c. When making the repairs specified in a. or b. above, stitching ends are not required to be backstitched. d. Loose
11、 or excessively tight stitching shall be repaired by removing the defective stitching, without damaging the materials, and restitching in the required manner. 3.2.1.2 Repairs of type 304 stitching. Thread breaks, bobbin runouts, skipped or loose stitches shall be repaired by completely removing the
12、stitching, without damaging the materials, and restitching in the required manner. 3.2.2 Thread ends. All thread ends shall be trimmed to a one fourth inch maximum length. 3.2.3 Webbing ends. All exposed webbing ends shall be hot cut or fused to prevent fraying. 3.3 Performance characteristics. 3.3.
13、1 Interface and fit. The holster shall be capable of proper interface and fit with the M9 pistol. Neither complete insertion nor withdrawl of the pistol- shall cause functionally significant movement of any of the pistols controls (e.g., the safety shall not be moved from the safe to the fire positi
14、on or vice versa; the magazine catch shall not release the magazine; the slide or hammer shall not be retracted so as to cause the hammer to approach the half-cocked position) . 3.3.2 D-ring fla9. The force required to release the flaps D-ring when an M9 pistol is completely inserted into the holste
15、r shall not be less than 6 lbs, nor more than 10 lbs. 3.3.3 D-ring flap. The force required to release the flap D-ring when the holster is empty shall not be less than 3 lbs. i 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-467L LO 7779706 0
16、323307 5 MIL-H-48671 (AR) 3.3.4 Belt fastener. The force required to release each side a of the belt fastener wireform shall not be less than 8 lbs, nor more than 12 lbs. 3.3.5 Belt fastener assembly. The belt fastener assembly wireform shall be capable of free standing within its own weight at 900
17、to the backplate. The weight required for downward movement beyond 45O shall not exceed 12 ounces. 3.4 Identification marking. Each holster shall be idelibly marked with the letters “US“, “M12“, part number, manufacturers name and FSCM code. Markings shall be molded positive or negative iii relief o
18、n the plastic facing, conform to MIL-STD-130 and- be in the location and size indicated on the applicable drawing. instruction sheet ect criteria as ssecified in 4.5.4.1. to determine that packaging, packing and marking requirements comply to section 5 requirements. Inspection shall be in accordance
19、 with the classification of defects listed below. The sample unit shall be one shipping container fully packaged. The iot size shall be the number of containers in the inspection lot. The inspection level shall be S-4 with an AQL of 4.0 defects per hundred units in accordance with MIL-STD-105. 4.5.6
20、 Examination of packagia. An examination shall be made Characteristic Marking Workmanship Content Materials Defect Omitted; incorrect; illegible; of improper size, location, sequence, or method of application. Improper taping, incomplete closure, bulged or distorted container. Number of holsters per
21、 container is more or less than specified. Any omitted, damaged, or not as specified. 4.6 Methods of. inspection. 4.6.1 Interface and fit test. Test samples selected for interface and fit testing shali be suspended as in service. A sistol for which the holster was designed shall be manually inserted
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILH486711988HOLSTERHIPM12M12 手枪 皮套 静压 PDF

链接地址:http://www.mydoc123.com/p-445088.html