1、MILITARYFINISHING SECTION,INCH-POUNDMIL-F-44402(GL)16 February 1990SPECIFICATIONMODULAR PRINTING SYSTEMThis specification is approved for use by the Natick Research, Development, andEngineering Center, Department of the Army, and is available for use by allDepartments and Agencies of the Department
2、of Defense.1. SCOPE1.1 Scope. This specification covers the finishing section of the ModularPrinting System (see 6.1).2. APPLICABLE DOCUMENTS2.1 Government Documents.2.1.1 Specifications, standards, and handbooks. The following specifi-cations, standards, and handbooks form a part of this document t
3、o the extentspecified herein. Unless otherwise specified, the issues of these documents arethose listed in the issue of the Department of Defense Index of Specificationsand Standards (DODISS) and supplement thereto, cited in the solicitation (see6.2).Beneficial comments (recommendations, additions,
4、deletions) and anypertinent data which may be of use in improving this document should beaddressed to: U.S. Army Natick Research, Development, and EngineeringCenter, Natick, MA 01760-5014 by using the self-addressed StandardizationDocument Improvement Proposal (DD Form 1426) appearing at the end of
5、thisdocument or by letter.1 tAMSC N/A FSC 3610DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-44402(GL)SPECIFICATIONSMILITARYMIL-D-3464 - Desiccants, Activated, Ba
6、gged, Packaging Use andStatic DehumidificationMIL-S-44195 - Shelter, Tactical, Expandable, Two-SideSTANDARDS .MILITARYMIL-STD-105 - Sampling Procedures and Tables for Inspectionby Attributes(Unless otherwise indicated, copies of the federal and military specifica-tions, standards, and handbooks are
7、available from the Standardization DocumentsOrder Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094. )2.1.2 Other Government documents, drawings, and publications. The followingother Government documents, drawings, and publications form a part of thisdocument to the extent specified he
8、rein. Unless otherwise specified, the issuesare those cited in the solicitation.Department of the Army Technical ManualsTM 5-3610-294-13&P - Operators Unit and Intermediate Direct SupportMaintenance Manual including Repair Parts and Special Tools List forModular Printing System, Module C - Finishing
9、 Section(Copies of the Army Technical Manuals are available from the U.S. AGPublications Center, 1655 Woodson Road, St. Louis, MO 63144.)DRAWINGSUs. ARMY NATICK RESEARCH, DEVELOPMENT, AND ENGINEERING CENTER5-13-46995-13-47335-13-47635-13-49935-13-50015-13-50105-13-50255-1.3-50265-13-5029Finishing Sh
10、elter Arrangement24,000 BTU Heat Pump36,000 BTU Heat PumpPaper CutterStencil, Center of GravityModifications, Exterior WallsShelter, Outside MODS (Finshing)Data Plate, Transportation DataData Plate, Identification, Finishing Section(Copies of drawings are available from the U.S. Army Natick Research
11、,Development, and Engineering Center, ATTN: STRNC-EMSS, Natick, MA 01760-5014. ). 2LProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-44402(GL)2.2 Non-Government publications. The following documents forms a part ofthis document to the extent spe
12、cified herein. Unless otherwise specified, theissues of the documents which are DoD adopted are those listed in the issue ofthe DODISS cited in the solicitation. Unless otherwise specified, the issues ofdocuments not listed in the DODISS are the issues of the documents cited in thesolicitation (see
13、6.2).INATIONAL FIRE PROTECTION ASSOCIATIONINFPA No. 70 - National Electrical Code HandbookI(Application for copies should be addressed to the National Fire ProtectionAssociation, 80 Battery March Pike, Quincy, MA 02169.)I(Non-Government standards and other publications are normally available fromthe
14、 organizations that prepare of distribute the documents. These documentsalso may be available in or through libraries or other informational services.)I2.3 Order of precedence. In the event of a conflict between the text of thisdocument and the references cited herein, the text of this document take
15、sI precedence. Nothing in this document, however, supersedes applicable laws and3. REQUIREMENTS3.1 First article. When specified (see 6.2), a sample shall be subjected tofirst article inspection (see 6.3) in accordance with 4.3.3.2 Alternate components. Components offered as equivalent to components
16、specified hereinafter and on the referenced drawings as a specificmanufacturers part or model number or equal, shall be functionally equal to themanufacturers model number identified, and of equal or better quality. Theincorporation and inclusion of such a component in the design of the specifiedend
17、 product shall not require modification or change to any other specifiedcomponent, and shall not reduce ease of maintenance to it or any othercomponents, unless such modification or change is specifically approved by thecontracting officer. Prior to manufacture of the first article, or if none isreq
18、uired, prior to commencing production, the contractor shall submit for thecontracting officers approval, a list identifying each proposed alternatecomponent, together with proof that each listed component complies withrequirements specified above. The contracting officer, at his option, mayrequire a
19、 physical sample of the proposed substitution. Approval of thesubmitted listing, together with the necessary supporting data, authorizescommencement of manufacture but does not relieve the contractor ofresponsibility that these components perform in accordance with specifiedrequirements when incorpo
20、rated into the end product.3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-44402(GL)3.2.1 Materials and components. The materials and components shall be asspecified herein and on the applicable drawings. Materials and components notdefinitely
21、 specified shall be-of the quality normally used by the manufacturerprovided the completed item complies with all the provisions of thisspecification. It is encouraged that recycled material be used when practicalas long as it meets the requirements of this specification.3.3 Design and construction.
22、 The design and construction of the finishingsection shall be as specified herein, and in Drawing 5-13-4699 and allsubsidiary drawings and parts lists pertaining thereto. All wiring shall be inaccordance with the provisions of NFPA No. 70.3.4 Finishing section operation. All electrically operated eq
23、uipment,including switches, lights. telephone, papercutter, and heat pumps shallfunction without failure when tested for performance and readability asspecified in 4.5.1 and 4.5.2.3.5 Shelter. The shelter (see 3.8) shall be either desert sand or camouflagegreen as specified see 6.2). All interior an
24、d exterior surfaces of the sheltershall be cleaned and rehabilitated when necessary to restore the original colorand finish.3.6 Technical manuals. Technical manual, 5-3610-294-13&P, shall be providedwith the Finishing Section and shall be located within the cabinet next to thepapercutter.3.7 Marking
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILF444021990FINISHINGSECTIONMODULARPRINTINGSYSTEM 印刷 系统 工段 PDF

链接地址:http://www.mydoc123.com/p-444641.html