ARMY MIL-DTL-52876 D-1997 CABINETS MONITOR CY-7359 FSS-9(V) CY-7360 FSS-9(V) AND CY-7361 FSS-9(V).pdf
《ARMY MIL-DTL-52876 D-1997 CABINETS MONITOR CY-7359 FSS-9(V) CY-7360 FSS-9(V) AND CY-7361 FSS-9(V).pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-DTL-52876 D-1997 CABINETS MONITOR CY-7359 FSS-9(V) CY-7360 FSS-9(V) AND CY-7361 FSS-9(V).pdf(39页珍藏版)》请在麦多课文档分享上搜索。
1、INCH -POUNDMIL -DTL -52876D4 August 1997SUPERSEDINGMIL -C -0052876C(ME)11 July 1986 andMIL -C -52876B28 August 1980DETAIL SPECIFICATIONCABINETS, MONITOR, CY -7359/FSS -9(V)CY -7360/FSS -9(V), AND CY -7361/FSS -9(V)Inactive for new design after 4 August 1997.This specification is approved for use by
2、all Departments and Agencies ofthe Department of Defense.1. SCOPE1.1 Scope. This specification covers three types of monitor cabinets withintegral power supplies and mounting facilities with interface connections forthe status and alarm monitor modules. The cabinets are components of theJoint -Servi
3、ces Interior Intrusion Detection System (J -SIIDS).1.2 Classification. Monitor cabinets are of the following types, asspecified (see 6.2):Type A - One Zone Monitor Cabinet, CY -7359/FSS -9(V).Type B - Five Zone Monitor Cabinet, CY -7360/FSS -9(V).Type C - Twenty -five Zone Monitor Cabinet, CY -7361/
4、FSS -9(V).2. APPLICABLE DOCUMENTS2.1 General. The documents listed in this section are specified insections 3 and 4 of this specification. This section does not includedocuments cited in other sections of this specification or recommended foradditional information or as examples. While every effort
5、has been made toensure the completeness of this list, document users are cautioned that theymust meet all specified requirements documents cited in sections 3 and 4 ofthis specification, whether or not they are listed.Beneficial comments (recommendations, additions, deletions) and any pertinentdata
6、which may be of use in improving this document should be addressed to: USArmy CECOM, ATTN: AMSEL -LC -IEW -D -ED, 10115 Gridley Rd, Suite 228, Ft Belvoir,VA 22060 -5849 by using the Standardization Document Improvement Proposal ( DDForm 1426) appearing at the end of this document or by letter.AMSC N
7、/A FSC 6350DISTRIBUTION STATEMENT A. Approved for public release; distribution isunlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL -DTL -52876D22.2 Government documents.2.2.1 Standards and handbooks. The following standards and handbooks
8、forma part of this document to the extent specified herein. Unless otherwisespecified, the issues of these documents are those listed in the issue of theDepartment of Defense Index of Specifications and Standards (DoDISS) andsupplement thereto cited in the solicitation (see 6.2).STANDARDSDEPARTMENT
9、OF DEFENSEMIL -STD -130 - Identification Marking of US Military Property.MIL -STD -889 - Dissimilar Metals.HANDBOOKSDEPARTMENT OF DEFENSEMIL -HDBK -454 - General Guidelines for Electronic Equipment.MIL -HDBK -781 - Reliability Test Methods, Plans and Environmentsfor Engineering Development, Qualific
10、ation andProduction.(Unless otherwise indicated, copies of the above standards and handbooks areavailable from the Standardization Document Order Desk, 700 Robbins Avenue,Building 4D, Philadelphia, PA 19111 -5094.)2.2.2 Government drawings. The following Government drawings form a partof this docume
11、nt to the extent specified herein. Unless otherwise specified,the issues are those cited in the solicitation.DRAWINGSMETA13220E3900 - Cabinet, Monitor, 1 Zone, CY -7359/FSS -9(V).TA13220E3901 - Power Supply, 1 Zone Monitor.TA13220E3902 - Signal Module Assembly.TA13220E4000 - Cabinet, Monitor, 5 Zone
12、 , CY -7360/FSS -9(V).TA13220E4001 - Power Supply, 5 Zone Monitor.TA13220E4100 - Cabinet, Monitor, 25 Zone, CY -7361/FSS -9(V).TA13220E4101 - Power Supply, 25 Zone Monitor.(Copies of drawings required by contractors in connection with specificacquisition functions should be obtained from: US Army CE
13、COM, IEWSDirectorate, ATTN: AMSEL -LC -IEW -D -CE, 10115 Gridley Rd, Suite 228, FtBelvoir, VA 22060 -5849.)2.3 Non -Government publications. The following documents form a part ofthis document to the extent specified herein. Unless otherwise specified, theissues of the documents which are DoD adopte
14、d are those listed in the issue ofthe DoDISS cited in the solicitation. Unless otherwise specified, the issuesof documents not listed in the DoDISS are the issues of the documents cited inthe solicitation (see 6.2).AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)ASQC Z1.4 - Sampling Procedures and Table
15、s for Inspection byAttributes.ISO 10012 -1 - Quality Assurance Requirements for Measuring Equ ipment. Part 1: Metrological confirmation system for measuringequipment.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL -DTL -52876D3(Application for co
16、pies should be addressed to the: American NationalStandards Institute (ANSI), 11 West 42nd Street, New York, NY 10036.)AMERICAN WELDING SOCIETY (AWS)D9.1 - Welding of Sheet Metal.(Application for copies should be addressed to: American Welding Society,550 NW LeJeune Rd, PO Box 351040, Miami, FL 3313
17、5.)2.4 Order of precedence. In the event of a conflict between the text ofthis document and the references cited herein, the text of this document takesprecedence. Nothing in this document, however, supersedes applicable laws andregulations unless a specific exemption has been obtained.3. REQUIREMEN
18、TS3.1 Description. The 1 zone, 5 zone, and 25 zone monitor cabinets shall bein accordance with TA13220E3900, TA13220E4000, and TA13220E4100, respectively,and as specified herein.3.1.1 Major components. The major components of the monitor cabinets shallbe as follows:a. Signal modul e assembly: TA1322
19、0E3902.b. Power supply: TA13220E3901, TA13220E4001, and TA13220E4101 for the 1,5, and 25 zone monitor cabinets respectively.When specified (see 6.2), any of the major components listed above shall befurnished separately.3.1.2 Drawings. The drawings forming a part of this specification are endproduct
20、 drawings. No deviation from the prescribed dimensions or tolerancesis permissible without prior approval of the contracting officer. Wheretolerances could cumulatively result in incorrect fits, the contractor shallprovide tolerances within those prescribed on the drawings to ensure correctfit, asse
21、mbly and operation of the monitor cabinet. Any data (e.g., shopdrawings, layouts, flow sheets, processing procedures, etc.) prepared by thecontractor or obtained from a vendor to support fabrication and manufacture ofthe production item shall be made available, upon request, for inspection bythe con
22、tracting officer or designated representative.3.2 First article. When specified (see 6.2), a sample shall be subjectedto first article inspection in accordance with 4.2.3.3 Material. Material shall be as specified herein and on the applicabledrawings. Materials not specified shall be selected by the
23、 contractor andshall be subject to all provisions of this specification.3.3.1 Material deterioration prevention and control. The monitor cabinetsshall be fabricated from compatible materials, inherently corrosion resistantor treated to provide protection against the various forms of corrosion anddet
24、erioration that may be encountered in any of the applicable operating andstorage environments to which the monitor cabinet may be exposed.3.3.2 Dissimilar metals. Dissimilar metals shall not be used in intimatecontact with each other unless protected against galvanic corrosion.Dissimilar metals and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL52876D1997CABINETSMONITORCY7359FSS9VCY7360FSS9VANDCY7361FSS9VPDF

链接地址:http://www.mydoc123.com/p-444361.html