1、INCH -POUNDDISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.MIL-DTL-51227C25 September 2013SUPERSEDINGMIL-P-51227B27 June 1972DETAIL SPECIFICATIONPUMP, CENTRIFUGAL, DECONTAMINATING APPARATUSInactive for new design after 14 March 1996This specification is approved for
2、use by the U.S. Army EdgewoodChemical Biological Center and is available for use by all Depart-ments and Agencies of the Department of Defense.1. SCOPE1.1 Scope. This specification covers a pump for a decontaminating apparatus.2. APPLICABLE DOCUMENTS2.1 General. The documents listed in this section
3、are specified in sections 3 or 4 of thisspecification. This section does not include documents cited in other sections of this specifica-tion or recommended for additional information or as examples. While every effort has beenmadetoensurethecompletenessofthislist, documentusersarecautionedthattheym
4、ustmeetall specifiedrequirementsofdocumentscitedinsections3or4ofthisspecification, whetherornot they are listed.2.2 Government documents.2.2.1 Specifications, standards, and handbooks. The following specifications, standards,and handbooks form a part of this document to the extent specified herein.
5、Unless otherwisespecified, the issues of these documents are those cited in the solicitation or contract.AMSC N/A FSC 4230Comments, suggestions, or questions on this document should be addressed to: U.S. Army EdgewoodChemicalBiologicalCenter, ATTN: RDCB-DEA-S, 5183BlackhawkRoad,AberdeenProvingGround
6、,MD 21010-5424oremailedtoAPGR-EcbcSpecsTeamconus.army.mil. Sincecontact informationcanchange, youmaywant toverifythecurrencyofthisaddressinformationusingtheASSIST Onlinedatabaseat https:/assist.dla.mil.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
7、MIL-DTL-51227C2DEPARTMENT OF DEFENSE SPECIFICATIONSMIL-DTL-12468 -Decontaminating Agent, STBMIL-DTL-51027 -Antisetting Compound, Decontaminating Slurry, M2DEPARTMENT OF DEFENSE STANDARDSMIL-STD-1916 - Preferred Methods for Acceptance of Product(Copies of these documents are available online at http:
8、/quicksearch.dla.mil/ or from theStandardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA19111-5094.)2.2.2 OtherGovernmentdocuments,drawings,andpublications. ThefollowingotherGov-ernment documents, drawings, and publications form a part of this document to the extentspe
9、cified herein. Unless otherwise specified, the issues of these documents are those cited inthe solicitation or contract.U.S. ARMY EDGEWOOD CHEMICAL BIOLOGICAL CENTERDRAWINGS5-45-2835 - Pump Assembly(Copies of these documents are available from U.S. Army Edgewood Chemical BiologicalCenter, ATTN: RDCB
10、-DEA-D, 5183 Blackhawk Road, Aberdeen Proving Ground, MD21010-5424.)2.3 Non-Governmentpublications. Thefollowingdocuments forma partofthisdocumentto the extent specified herein. Unless otherwise specified, the issues of these documents arethose cited in the solicitation or contract.AMERICAN INSTITUT
11、E OF CHEMICAL ENGINEERSAICHE E -31 - Centrifugal Pumps (Newtonian Liquids): A Guide toPerformance Evaluation, third edition(Copies of this document are available from http:/www.aiche.org/ or American Institute ofChemical Engineers (AIChE), 3 Park Avenue 19 Fl, New York, NY 10016-5991.)2.4 Order of p
12、recedence. Unless otherwise noted herein or in the contract, in the event ofa conflict betweenthe textof thisdocument andthe referencescited herein(except forrelatedspecification sheets), the text of this document takes precedence. Nothing in this document,however, supersedes applicable laws and reg
13、ulations unless a specific exemption has been ob-tained.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-51227C33. REQUIREMENTS3.1 Firstarticle. Whenspecified(see6.2),asampleshallbesubjectedtofirstarticleinspec-tion in accordance with 4.2.3.2
14、Design and construction.3.2.1 Materials. All materials cited on Drawing 5-45-2835 and its subsidiary drawingsshall conform to the specifications listed thereon or to the specific characteristics set forth onthe drawings. Material not definitely specified shall be of a quality regularlyused bymanufac
15、-turers of pumping equipment.3.2.2 Components. Allcomponentsoftheitemshallconformtothespecificationsanddraw-ings listed on Drawing 5-45-2835 and subsidiary drawings.3.2.3 Manufactureand assembly. The item shall be manufactured andassembled as shownon Drawing 5-45-2835.3.3 Functioning. The pumpshall
16、meetthe followingrequirementswhenrunningat 4400100revolutionsperminute(rpm)foraminimumperiodof15minuteswhentested asspecifiedin 4.4.1.(a) Discharge 100 gallons per minute (gpm) minimum of water at a discharge headof 205 feet1 foot with a minimum static lift of 15 feet.(b) Operate smoothly and not le
17、ak.(c) Prime in a maximum of 4 minutes by using no more than 9 gallons of water.3.4 Performance. The pump running at 4400100 rpm shall be capable of delivering aminimum of 50 gpm of STB slurry, made in accordance with 4.4.2, at a discharge head of 290feet1footandaminimumdynamicliftof10feet. Thepump
18、shall also delivera minimumof100 gpm of water at a discharge head of 205 feet1 foot with a minimum static lift of 15 feetwhen running at 4400100 rpm. The total head at zero flow shall be a minimum of 300 feet.The required horsepower (hp) to drive the pump shall not exceed 20 hp when running at440010
19、0 rpm andpumpinga minimum of50 gpm ofSTBslurryoranequivalentmassflowofwater at a minimum of 140 pounds per square inch (psi) at the discharge gage.3.5 Endurance. The pump shall be operated for a minimum of 250 hours with only minoradjustments. The pump shall operate smoothly without overloading or l
20、eakage when tested asspecified in 4.4.3.3.6 Performance curve. The discharge head versus capacity curve of the pump when testedas specified in 4.4.4 shall slope continuously from high head downward toward high capacity.The curve may approach constant head as the capacity increases but the head may n
21、ever in-Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-51227C4crease. The head capacity coordinates indicated in 3.3 shall be on or below the pump perfor-mance curve.3.7 Weight. The assembledpump weightshall notexceed 100pounds whentested as
22、speci-fied in 4.4.5.3.8 Cavitation. Cavitation shall not occur when tested as specified in 4.4.6.3.9 Firstarticle. Whenspecified(see6.2),asampleshallbesubjectedtofirstarticleinspec-tion in accordance with 4.2.3.10 Workmanship. The pump shall be free from contamination (foreign matter, oil orgrease)
23、and damage such as cracks , burrs and sharp edges.4. VERIFICATION4.1 Classification of inspections. The inspection requirements specified herein are classi-fied as follows:(a) First article inspection (see 4.2)(b) Conformance inspection (see 4.3)4.2 First article inspection.4.2.1 Sample. The first a
24、rticle sample shall consist of two pumps manufactured using thesame methods, materials, equipment, and processes as will be used during regular production.The first article sample shall be submitted for inspection and approval in accordance with theterms of the contract.4.2.2 Inspection procedure. T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL51227C2013PUMPCENTRIFUGALDECONTAMINATINGAPPARATUSPDF

链接地址:http://www.mydoc123.com/p-444355.html