1、INCH -POUNDMIL-DTL-51222E(EA)22 July 2008SUPERSEDINGMIL-DTL-51222D(EA)22 October 1997DETAIL SPECIFICATIONFILTER, GAS, 150 CFM, M23A1Inactive for new design after 28 September 1995This specification is approved for use by the U.S. Army EdgewoodChemicalBiologicalCenterandisavailableforusebyallDepartme
2、ntsand Agencies of the Department of Defense.1. SCOPE1.1 Scope. Thisspecificationcoversonetypeandonesizeoftoxicgasfilter.2. APPLICABLE DOCUMENTS2.1 General. The documents listed in this section are specified in sections 3 and 4 of thisspecification. This section does not include documents cited inot
3、her sections of this specifica-tion or recommended for additional information or as examples. While every effort has beenmadetoinsurethecompletenessofthislist,documentusersarecautionedthatthey mustmeetall specified requirements documents cited in sections 3 and 4 of this specification, whether ornot
4、 they are listed.AMSC N/A FSC 4240Comments, suggestions, or questions on this document should be addressed to: U.S. Army EdgewoodChemicalBiologicalCenter,ATTN: AMSRD-ECB-ENA-S,5183BlackhawkRoad, AberdeenProvingGround, MD 21010-5424 or emailed to SpecsTeamapgea.army.mil. Since contact information can
5、change,youmaywanttoverifythecurrencyofthisaddressinformationusingtheASSISTOnlinedatabaseat http:/assist.daps.dla.mil.DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-
6、DTL-51222E(EA)22.2 Government documents.2.2.1 Specifications, standards, and handbooks. The following specifications, standards,and handbooks form a part of this document to the extent specified herein. Unless otherwisespecified, the issues of these documents are those cited in the solicitation or c
7、ontract.FEDERAL STANDARDSFED-STD-191 - Textile Test MethodsDEPARTMENT OF DEFENSE SPECIFICATIONSMIL-DTL-32101 - Carbon, Activated, Impregnated,Copper-Silver-Zinc -Molybdenum - Triethylenediamine(ASZM - TEDA)(Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ orht
8、tp:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Ave-nue, Building 4D, Philadelphia, PA 19111-5094.)2.2.2 OtherGovernmentdocuments, drawings, andpublications. ThefollowingotherGov-ernmentdocuments, drawings, andpublicationsforma partofthisdocumenttothe extentspe-c
9、ified herein. Unless otherwise specified, the issues of these documents are those cited in thesolicitation or contract.U.S. ARMY EDGEWOOD CHEMICAL BIOLOGICAL CENTERDRAWINGS5-19-2298 - Filter, Gas, 150 CFM, M23A1136-41-5000 - Tester, Filter Life, Q262, Assembly(Copies are available from Technical Dir
10、ector, U.S. Army Edgewood Chemical BiologicalCenter, AMSRD-ECB-ENA-D, Aberdeen Proving Ground, MD 21010-5424.)2.3 Non-Governmentpublications. Thefollowingdocumentsforma partofthisdocumentto the extent specified herein. Unless otherwise specified, the issues of these documents arethose which are cite
11、d in the solicitation or contract.AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)ASTM D 2867 -Moisture in Activated Carbon(Copiesofthisdocumentareavailablefromwww.astm.orgorASTMInternational,100BarrHarbor Drive, West Conshohocken, PA 19428-2959.)Provided by IHSNot for ResaleNo reproduction or netw
12、orking permitted without license from IHS-,-,-MIL-DTL-51222E(EA)3AIR-CONDITIONING AND REFRIGERATION INSTITUTE (ARI)ARI STANDARD 700 - Standard for Specifications for Fluorocarbons and otherRefrigerants(Copies are available from ARI, 4100 N. Fairfax Dr., Suite 200, Arlington, VA 22203http:/www.ari.or
13、g).2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event ofaconflictbetweenthetextofthisdocumentandthereferencescitedherein,thetextofthisdoc-ument takes precedence. Nothing in this document, however, supersedes applicable laws andregulations unless a specific exempt
14、ion has been obtained.3. REQUIREMENTS3.1Materialsandcomponents.AllmaterialsandcomponentscitedonDrawing5-19-2298andsubsidiarydrawingsshallconformtothespecificationslistedthereonortothespecificchar-acteristics setforthonthe drawings. No visible growthof mildew shall be evident whentestedinaccordancewi
15、thmethod5750ofFED-STD-191. Cottonclothshallbewaterrepellentandhave a minimum spray rating of 50.0 when tested in accordance with method 5526 of FED-STD-191.3.2 Assembly. The assembly of the gas filter shall be consistent with Drawing 5-19-2298(see 6.3).3.3 First article. When specified (see 6.2), a
16、sample shall be subjected to the first articleinspection in accordance with 4.2.3.4 Airflowresistance. Theairflowresistanceofthefiltershallnotexceed4.5inches(114.3mm)ofwatergage(iwg)ata150standardcubicfeetperminute(scfm)airflowratewithanairstreamtemperatureof70_F(21_C)andabarometricpressureofoneatmo
17、sphere(760mmHg)when tested as specified in 4.4.1.3.5 Filter Leakage. Thefilter shall notleak whena concentrationof 1000parts permillion(ppm) of R-134a (1,1,1,2 Tetrafluoroethane) refrigerant is introduced at the inlet of the filterat a flow rate of 30 scfm when tested in accordancewith 4.4.2. Theref
18、rigerant (R-134a)shallconform to the characteristics of ARI STANDARD 700. A filter leak shall be defined as theProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-51222E(EA)4detection of 1 ppm or more of R134a in the effluentair within2 minutesaf
19、ter theintroductionofrefrigerantattheinletofthefilter.3.6 Moisturecontentofgasfilter. Themoisture contentofthecarbonineachfilterimmedi-atelybefore packagingshall notexceed3.0 percentbyweightwhentestedas specifiedin4.4.3.3.7 Rough handling. After roughing handling in accordancewith 4.4.4, sample filt
20、ersshallshow no evidence of cracks, dents, or carbon granule leakage upon visual inspection.3.8 Dimethylmethylphosphonate(DMMP) life. Thefiltershallhave aDMMPgaslife ofnoless than 55 minutes at rated flow when tested in accordance with 4.4.5.3.9 Cyanogen Chloride (CK) life. The unaged CK life of the
21、 carbon samples taken duringthe filling process shall be not less than 90% of the unaged CK life requirement of MIL-DTL-32101, when tested in accordance with 4.4.6.3.10 Identification and markings. The markingofeachfilter shall include the name oftheitem (Filter, Gas 150 CFM, M23A1) and lot number a
22、s a minimum. Verification shall be inaccordance with 4.3.5. Additional information may be required by solicitation (see 6.2).3.11 Workmanship. The filter shall be free from foreign matter (e.g. dirt, grease, oil) anddamage such as chipped, burred or bent sections, or loose, broken or frayed gasket m
23、aterial.Verification shall be in accordance with 4.3.5.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-51222E(EA)54. VERIFICATION4.1 Classification of inspections. The inspection requirements specified herein are classi-fied as follows:(a) Fi
24、rst article inspection (see 4.2)(b) Conformance inspection (see 4.3)4.2 First article inspection.4.2.1 Sample. The first article sample shall consist of 10 consecutively produced filterswhich pass airflow and leakage requirements (3.4 and 3.5). The first article sample shall bemanufactured and packa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL51222E2008DETAILSPECIFICATIONNFILTERGAS150CFMM23A1M23A1 150 CFM 气体 过滤器 PDF

链接地址:http://www.mydoc123.com/p-444354.html