ANSI UL 219-2013 UL Standard for Safety Lined Fire Hose for Interior Standpipes (Fourth Edition)《室内立管用有衬里消防软管的安全性标准》.pdf
《ANSI UL 219-2013 UL Standard for Safety Lined Fire Hose for Interior Standpipes (Fourth Edition)《室内立管用有衬里消防软管的安全性标准》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 219-2013 UL Standard for Safety Lined Fire Hose for Interior Standpipes (Fourth Edition)《室内立管用有衬里消防软管的安全性标准》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 219 Lined Fire Hose for Interior StandpipesUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FO
2、R FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Lined Fire Hose for Interior Standpipes, UL 219 Fourth Edition, Dated October 25, 2013 SUMMARY OF TOPICS This new edition of ANSI/UL 219 includes the following: 1. Revision to scope with respect to NFPA refe
3、rences, paragraphs 1.1, 1.2, 1.3 2. Revision to correct typographical error, paragraph 6.3 3. Revision to Kink Test with respect to hose length, paragraphs 9.1.1, 9.3.1 4. Revision to Repeated Bending Test to add tolerances to test parameters, paragraph 11.2.1 5. Revision to Ozone-Exposure Test with
4、 respect to outside reference, paragraphs 20.2.1, 20.3.1 The revised requirements are substantially in accordance with Proposal(s) on this subject dated June 21, 2013 and August 30, 2013. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
5、 in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any
6、purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has
7、 been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and ag
8、ainst any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for t
9、hose paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are pre
10、ceded by a SUPERSEDED REQUIREMENTS notice. OCTOBER 25, 2013 UL 219 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 25, 2013 UL 219 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBU
11、TION WITHOUT PERMISSION FROM UL OCTOBER 25, 2013 1 UL 219 Standard for Lined Fire Hose for Interior Standpipes First Edition January, 1983 Second Edition April, 1993 Third Edition October, 2006 Fourth Edition October 25, 2013 This ANSI/UL Standard for Safety consists of the Fourth Edition. The most
12、recent designation of ANSI/UL 219 as an American National Standard (ANSI) occurred on October 24, 2013. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. ULs Standards for Safety are copyrighted by UL. Neither a printed nor el
13、ectronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time.
14、Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC. ANSI/UL 219-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OC
15、TOBER 25, 2013 LINED FIRE HOSE FOR INTERIOR STANDPIPES - UL 219 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 General 5 2.1 Units of measurement .5 2.2 Components .6 2.3 Undated Refe
16、rences 6 CONSTRUCTION 3 Length .6 4 Internal Diameter .6 5 Reinforcement 7 6 Lining 7 7 Cover 7 PERFORMANCE 8 Hydrostatic Proof-Pressure Tests .8 8.1 General .8 8.2 Apparatus .8 8.3 Test method .9 9 Kink Test .10 9.1 General 10 9.2 Apparatus 10 9.3 Test method 10 10 Hydrostatic Strength Test 11 10.1
17、 General .11 10.2 Apparatus .11 10.3 Test method .11 11 Repeated-Bending Test .11 11.1 General .11 11.2 Apparatus .12 11.3 Test method .12 12 Wet Hose Test .12 12.1 General .12 12.2 Apparatus .13 12.3 Test method .13 13 Fold-Resistance Test 13 13.1 General .13 13.2 Apparatus .13 13.3 Test method .13
18、 14 Abrasion Test 13 14.1 General .13 14.2 Apparatus .14 14.3 Test method .14 15 Heat-Resistance Test .15 15.1 General .15 15.2 Apparatus .15 15.3 Test method .15 OCTOBER 25, 2013 LINED FIRE HOSE FOR INTERIOR STANDPIPES - UL 219 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DIS
19、TRIBUTION WITHOUT PERMISSION FROM UL 16 Accelerated-Aging Test Of Threads .15 16.1 General .15 16.2 Apparatus .15 16.3 Test method .16 17 Adhesion Tests .16 17.1 Lining .16 17.2 Cover .16 17.3 Apparatus .16 17.4 Test method .17 18 Tensile Strength And Elongation Test .17 18.1 General .17 18.2 Appara
20、tus .18 18.3 Test method .19 19 Accelerated Air Oven Aging Test Of Linings Or Covers 19 19.1 General .19 19.2 Apparatus .20 19.3 Test method .20 20 Ozone Exposure Test .20 20.1 General .20 20.2 Apparatus .20 20.3 Test method .20 21 Water-Immersion Test Of Linings .21 21.1 General .21 21.2 Apparatus
21、.21 21.3 Test method .21 22 Test For Free Sulfur In Latex Lining .21 22.2 Apparatus and test method 21 MANUFACTURING AND PRODUCTION TESTS 23 General 22 MARKING 24 General 22 OCTOBER 25, 2013 LINED FIRE HOSE FOR INTERIOR STANDPIPES - UL 219 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUC
22、TION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover lined interior standpipe re hose in the 1-1/2 and 2-1/2 inch sizes that is intended: a) For re-protection purposes only; b) For use with inside standpipes installed in accordance with the Standard for t
23、he Installation of Standpipe and Hose Systems, NFPA 14; c) For use on hose racks and reels and in cabinets where the specic combination of hose and rack, reel, or cabinet has been investigated and found acceptable; d) To withstand infrequent service; and e) To be periodically inspected and maintaine
24、d while in service, as outlined in the Standard for the Care, Use, Inspection, Service Testing and Replacement of Fire Hose, Couplings, Nozzles and Fire Hose Appliances, NFPA 1962. 1.2 The 1-1/2 inch size hose is intended for use primarily by the building occupants for the control of incipient res u
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL2192013ULSTANDARDFORSAFETYLINEDFIREHOSEFORINTERIORSTANDPIPESFOURTHEDITION 室内 管用 衬里 消防 软管 安全性 标准

链接地址:http://www.mydoc123.com/p-439062.html