ANSI UL 1022-2012 UL Standard for Safety Line Isolation Monitors (Fifth Edition Reprint with revisions through and including August 3 2016)《线路绝缘监视器的安全性标准》.pdf
《ANSI UL 1022-2012 UL Standard for Safety Line Isolation Monitors (Fifth Edition Reprint with revisions through and including August 3 2016)《线路绝缘监视器的安全性标准》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 1022-2012 UL Standard for Safety Line Isolation Monitors (Fifth Edition Reprint with revisions through and including August 3 2016)《线路绝缘监视器的安全性标准》.pdf(53页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1022 Line Isolation Monitors STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZ
2、ED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Line Isolation Monitors, UL 1022 Fifth Edition, Dated April 16, 2012 SUMMARY OF TOPICS Revision pages have been issued for the Standard for Line Isolation Monitors, UL 1022, to reect the reaffirmation o
3、f the ANSI approval. No changes in requirements have been made. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL p
4、rovides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including lo
5、ss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid f
6、or this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any erro
7、r or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. AUGUST 3, 2016 UL 1022 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 3, 2016 UL 1022 tr2 No Text on This PageUL COPYRI
8、GHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 16, 2012 (Title Page Reprinted: August 3, 2016) 1 UL 1022 Standard for Line Isolation Monitors First Edition March, 1973 Second Edition July, 1979 Third Edition March, 1994 Fourth Edition June, 19
9、98 Fifth Edition April 16, 2012 This ANSI/UL Standard for Safety consists of the Fifth Edition including revisions through August 3, 2016. The most recent designation of ANSI/UL 1022 as a Reaffirmed American National Standard (ANS) occurred on August 3, 2016. ANSI approval for a standard does not in
10、clude the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards f
11、or Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES IN
12、C. ANSI/UL 1022-2012 (R2016)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 16, 2012 LINE ISOLATION MONITORS - UL 1022 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMIS
13、SION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 General 5 2.1 Components 5 2.2 Units of measurement .6 2.3 Undated references .6 3 Glossary 6 4 Instructions and Drawings .7 CONSTRUCTION 5 Enclosure 7 5.1 General 7 5.2 Cast metal enclosures .8 5.3 Sheet metal enclosures .8 5.4 Nonmetallic enclosures
14、9 5.5 Ventilating openings .10 5.6 Covers .11 5.7 Glass panels 11 6 Electric Shock 12 7 Corrosion Protection .12 8 Field-Wiring System Connections 13 8.1 General .13 8.2 Equipment grounding connection 14 9 Internal Wiring 14 9.1 General .14 9.2 Wireways .15 9.3 Splices .15 9.4 Barriers 15 9.5 Bushin
15、gs .15 9.6 Strain relief .16 10 Bonding for Grounding 16 11 Components 17 11.1 Current-carrying parts 17 11.2 Insulating material .18 11.3 Lampholders and lamps 19 11.4 Meters .19 11.5 Printed-wiring boards 19 11.6 Switches .19 11.7 Protective devices .20 11.8 Alarm silencing means .20 11.9 Audible
16、signaling appliance .20 11.10 Mounting of components 20 11.11 Operating components .21 12 Spacings .21 13 Servicing and Maintenance .22 APRIL 16, 2012 LINE ISOLATION MONITORS - UL 1022 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PERFORM
17、ANCE 14 General 23 15 Normal Operation Test .23 16 Sampling Circuit Supervision Test .25 17 Power Input Test 25 18 Leakage Current Measurements Test 25 19 Overvoltage and Undervoltage Test .30 19.1 Voltage operation 30 19.2 Undervoltage operation 30 20 Jarring Test 30 21 Temperature Test .31 22 Over
18、load Test .34 22.1 Monitor .34 22.2 Separately energized circuits .34 23 Endurance Test .35 23.1 Monitor .35 23.2 Devices and separately energized circuits 35 24 Variable Ambient Temperature Test .35 25 Humidity Test .36 26 Electric Shock Current Test .36 27 Transient Tests .40 27.1 General .40 27.2
19、 Externally-induced transients .40 27.3 Internally-induced transients 40 28 Dielectric Voltage-Withstand Test .41 29 Component Failure Test 42 30 Abnormal Operation Test .42 31 Test Switch Operation Test .42 MANUFACTURING AND PRODUCTION TESTS 32 General 42 33 Production-Line Leakage Current Measurem
20、ents Test .43 34 Production-Line Dielectric Voltage-Withstand Tests 43 MARKING 35 General 44 36 Supplementary 45 36.1 Installation drawing 45 36.2 Operating instructions 46 APPENDIX A Standards for ComponentsA1 APRIL 16, 2012 LINE ISOLATION MONITORS - UL 1022 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED
21、FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover dynamic line isolation monitors and related supplementary indicating units for supervising isolated power-supply circuits in patient care areas of health care facilities, including i
22、nhalation-anesthetizing locations in accordance with the National Electrical Code, NFPA 70. 1.2 The detectors and supplementary indicating units are intended to be: a) Included as part of an isolated power-supply center for patient care locations of health care facilities; and b) Installed in an Oth
23、er-Than-Hazardous (Classied) Location of a health care facility as dened by the National Electrical Code, NFPA 70. 1.3 These requirements do not cover ground fault circuit interrupters for use on grounded alternating current systems in accordance with the National Electrical Code, NFPA 70. 2 General
24、 2.1 Components 2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products covered by this standard. 2.1.2 A component is not re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL10222012ULSTANDARDFORSAFETYLINEISOLATIONMONITORSFIFTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGAUGUST32016

链接地址:http://www.mydoc123.com/p-438777.html