ANSI NEMA HP 8-2013 Electrical and Electronic Cross-Linked Modified Low-Smoke Polyolefin (XLPO) Insulated Hook-Up Wire Types LS (rated 105 600 V) ZHDM (rated 90 600 V) ZHDH (rated .pdf
《ANSI NEMA HP 8-2013 Electrical and Electronic Cross-Linked Modified Low-Smoke Polyolefin (XLPO) Insulated Hook-Up Wire Types LS (rated 105 600 V) ZHDM (rated 90 600 V) ZHDH (rated .pdf》由会员分享,可在线阅读,更多相关《ANSI NEMA HP 8-2013 Electrical and Electronic Cross-Linked Modified Low-Smoke Polyolefin (XLPO) Insulated Hook-Up Wire Types LS (rated 105 600 V) ZHDM (rated 90 600 V) ZHDH (rated .pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI/NEMA HP 8-2013Electrical and Electronic Cross-Linked, Modified Low-Smoke Polyolefin (XLPO) Insulated Hook-Up Wire, Types LS (rated 105C; 600 V), ZHDM (rated 90C; 600 V), ZHDH (rated 90C; 600 V), ZH (rated 125C; 600 V), and Z
2、HX (rated 125C; 1000 V)Approved as an American National Standard ANSI Approval Date: January 23, 2013 ANSI/NEMA HP 8-2013 Electrical and Electronic Cross-Linked, Modified Low-Smoke Polyolefin (XLPO) Insulated Hook-Up Wire, Types LS (rated 105C; 600 V), ZHDM (rated 90C; 600 V), ZHDH (rated 90C; 600 V
3、), ZH (rated 125C; 600 V), and ZHX (rated 125C; 1000 V) Published by: National Electrical Manufacturers Association 1300 North 17th Street, Suite 900 Rosslyn, VA 22209 www.nema.org Copyright 2013 by the National Electrical Manufacturers Association. All rights including translation into other langua
4、ges, reserved under the Universal Copyright convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. Copyright 2013 by the National Electrical Manufacturers Association. NOTICE AND DISCLAIMER The information in
5、this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this docume
6、nt. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons w
7、ho have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any infor
8、mation or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the
9、publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of
10、your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other servic
11、es for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exer
12、cise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it und
13、ertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safetyrelated information in this document shall
14、 not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. HP 8-2013 Page i Copyright 2013 by the National Electrical Manufacturers Association. CONTENTS FOREWORD . III SECTION 1 GENERAL . 1 1.1 SCOPE . 1 1.2 REFERENCE STANDARDS AND SPECIFICATIONS . 1 1
15、.3 RECOMMENDED USES OF WIRE TYPES . 1 1.3.1 TYPE LS 1 1.3.2 TYPE ZHDM, and ZHDH . 2 1.3.3 TYPE ZH . 2 1.3.4 TYPE ZHX . 2 1.4 PART IDENTIFICATION NUMBER (PIN) . 2 SECTION 2 CONDUCTORS . 4 2.1 CONDUCTOR MATERIALS . 4 2.2 CONDUCTOR COATINGS . 4 2.2.1 Tin-Coated Conductors . 4 2.2.2 Silver-Coated Conduc
16、tors . 4 2.3 STRANDING . 4 2.4 WIRE DIAMETER . 4 2.5 CONDUCTOR SPLICES 4 SECTION 3 INSULATION . 5 3.1 GENERAL . 5 3.2 XLPO INSULATION 5 SECTION 4 WIRE IDENTIFICATION 8 4.1 CIRCUIT IDENTIFICATION 8 4.1.1 Lay of Stripes. 8 4.2 IDENTIFICATION BY PRINTING . 8 4.2.1 Identification of Product . 8 SECTION
17、5 PHYSICAL AND ELECTRICAL REQUIREMENTS 9 5.1 GENERAL . 9 5.2 QUALITY CONFORMANCE INSPECTION OF FINISHED PRODUCT 9 5.2.1 Definitions 9 5.2.1.1 Inspection Lot . 9 5.2.1.2 Unit of Product 9 5.2.2 Sampling Inspection 9 5.3 WORKMANSHIP 9 5.4 MATERIALS CERTIFICATION . 9 SECTION 6 TEST PROCEDURES . 12 6.1
18、PHYSICAL TESTS 12 6.1.1 Test Temperature 12 6.1.2 Heat Resistance 12 6.1.3 Insulation Tensile Strength and Elongation . 12 6.1.4 Dimensional Inspection . 12 6.1.4.1 Conductor Diameter . 12 6.1.4.2 Insulation Diameter 12 6.1.4.3 Concentricity. 12 6.1.5 Shrinkage 13 6.1.6 Flammability 13 6.1.7 Heat Ag
19、ing Test . 13 6.1.8 Fungus Resistance 13 HP 8-2013 Page ii Copyright 2013 by the National Electrical Manufacturers Association. 6.1.9 Cold Bend 13 6.1.10 Halogen Content 13 6.1.11 Smoke Index 13 6.1.12 Toxicity Index . 13 6.1.13 Acid Gas Generation . 14 6.2 ELECTRICAL TESTS . 14 6.2.1 Conductor Resi
20、stance . 14 6.2.2 Spark or Impulse Test . 14 6.2.3 Dielectric Strength . 14 6.2.4 Insulation Resistance 14 6.2.5 Characteristic Impedance 14 SECTION 7 NOTES . 15 7.1 PACKAGING REQUIREMENTS 15 7.2 LABELING 15 7.3 LENGTHS . 15 SECTION 8 ORDERING DATA 16 8.1 ORDERING INFORMATION 16 Tables TABLE 1-1 CON
21、DUCTOR MATERIAL AND COATING . 2 TABLE 1-2 AWG NOMINAL CONDUCTOR SIZE 2 TABLE 1-3 NUMBER OF STRANDS . 3 TABLE 1-4 COLOR (SEE PARA 4.1) . 3 TABLE 3-1 DIMENSION BY WIRE TYPES 5 TABLE 3-2 IMPEDANCE PROPERTIES OF TWISTED PAIR CABLES FOR TYPE ZHDM AND ZHDH WIRES TESTED AT 1 MHZ 7 TABLE 4-1 LENGTH OF LAY O
22、F STRIPES . 8 TABLE 5-1 PHYSICAL AND ELECTRICAL REQUIREMENTS FOR TYPE LS, ZHD, ZH, AND ZHX WIRES . 10 TABLE 7-1 MINIMUM LENGTHS . 15 HP 8-2013 Page iii Copyright 2013 by the National Electrical Manufacturers Association. Foreword ANSI/NEMA HP 8-2013 (hereinafter referred to as ANSI/NEMA HP 8) was de
23、veloped by the NEMA High Performance Wire and Cable Section to define hook-up cables using low smoke and low or zero halogen insulation materials that might be used as an alternative to PVC-insulated cables for applications requiring these types of characteristics. In the preparation of ANSI/NEMA HP
24、 8, input of users and other interested parties has been considered. Proposed revisions, comments, and suggestions for the improvement of this document are encouraged. They should be sent to: Senior Technical Director, Operations National Electrical Manufacturers Association 1300 North 17th Street,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSINEMAHP82013ELECTRICALANDELECTRONICCROSSLINKEDMODIFIEDLOWSMOKEPOLYOLEFINXLPOINSULATEDHOOKUPWIRETYPESLSRATED105600VZHDMRATED90600VZHDHRATEDPDF

链接地址:http://www.mydoc123.com/p-437638.html