1、 1 ANSI/BHMA A156.29-2017 Revision of BHMA A156.29-2012 STANDARD FOR EXIT LOCKS, EXIT ALARMS, ALARMS FOR EXIT DEVICES SPONSOR BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. Approved by the AMERICAN NATIONAL STANDARDS INSTITUTE December 29, 2017 2 AMERICAN NATIONAL STANDARD An American National St
2、andard implies a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer and the general public. The existence of an American National Standard does not in any respect preclude anyone, whethe
3、r he has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. CAUTION NOTICE: This America
4、n National Standard is permitted to be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National Stan
5、dards receive current information on all standards by calling or writing the American National Standards Institute. Published by BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. 355 Lexington Avenue New York, New York 10017 Copyright 2017 by the Builders Hardware Manufacturers Association, Inc. No
6、t to be reproduced without specific authorization from BHMA Printed in the USA Portions of this standard were first published as a part of A156.5 for Auxiliary Locks ESD Immunity IEC 61000-4-2:2008; RF Immunity IEC 61000-4-3:2006; EFT Immunity IEC 61000-4-4:2004; ANSI/BHMA A156.18 2016, Materials an
7、d Finishes. 4. TEST METHODS 4.1 Samples for testing shall be selected at random from the manufacturers finished stock and mounted in accordance with the manufacturers instructions. All hardware shall be installed in accordance with manufacturers standard installation instruction. Operational Tests I
8、mmunity Tests Finish Tests No. of Samples One per applicable paragraph Three Two per finish 4.2 Test Door When doors are referenced, the tests shall be performed on 3 ft by 7 ft x 1 3/4 in. (915 x 2134 x 45 mm) minimum wood or metal doors with metal frames. The doors and frames shall be rigid enough
9、 to hold firmly and to withstand the tests outlined. Doors shall be hung on hinges or pivots. Provisions shall be made for mounting appropriate measuring devices. A combined calibration and reading accuracy within 5% shall be required for values indicated for all applicable tests. Reinforcement is p
10、ermitted to be used to prevent deformation of the door when the tests are being applied. 7 4.3 Slam Cycle Test Door Use a door meeting the description of 4.2. Use a door weighing 100 lbs. (45 kg) with the center of gravity located 18 in. (455 mm) from the hinge edge. Install the door in a steel fram
11、e with a 5/8 in. (15.9 mm) stop and mounted in a reinforced structure sufficient to withstand the test parameters. The door shall be installed to ensure door stop contact for the full height of the door. The stop contact surface shall not have any rubber bumpers or other cushioning means such as gas
12、keting. Doors shall be hung on hinges, accurately aligned with vertical pins or on offset or center pivots, With the closer disconnected, the force required to overcome friction or out of balance condition shall be 1/4 lbf. (1.1 N) or less as measured perpendicular to the face of the door at a point
13、 30 in. (762 mm) from pivot center. A size 3 door closer with hinge side mounting, 90 degrees door opening and type C01011, C02011, or C03011 shall be used. 8 5. OPERATIONAL TESTS 5.1 Applicability Table Paragraph 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 5.3.1 5.3.2 5.3.3 Product Normal exittestCycle test Emer
14、gency operation test Key cylinder operation test OutsidepulltestCycle test foralarmsSlam testImmunity compliance testStand alone alarm (wall mounted) X X X Stand alone alarm (door mounted) X X X X Exit lock with alarm X X X X X X X X Exit lock without alarm X X X X X Exit device with alarm X X X 5.2
15、 Tests For Exit Locks 5.2.1 Normal Exit Test With the door latched, the actuating member shall be depressed by a force not to exceed 15 lbf. (67 N) until the latch clears the strike. The measurement shall be taken at the center and 1.5 in. (38 mm) from each end on the actuating surface perpendicular
16、 to the door in the direction of swing. Portions of the actuating member which are below 30 in. (750 mm) and more than 44 in. (1100 mm) above the floor when installed per the manufacturers templating are exempt from this requirement. Requirements 15 lbf max. (67 N) for all measurement points 5.2.2 C
17、ycle Test Doors shall be opened by pushing on the actuating member. The door shall be required to close and latch by the operation of the door closer except that in the case of a lock with a dead bolt which must be reset before the start of the next cycle. Exit locks shall complete the required numb
18、er of cycles without failure or excessive wear that would impair operation. Requirements 100,000 cycles. At the completion of the test, the exit lock shall meet 5.2.1 and all alarm features shall function as intended 9 5.2.3 Emergency Operation Test Using the setup and procedure in 5.2.1, apply a ho
19、rizontal 250 lbf (1110 N) to the door approximately 3 in. (76 mm) from the latch edge and 40 in. (1020 mm) from the floor in the direction of the door swing. With the door latched, repeat the test in 5.2.1. The actuating paddle shall be depressed by a force not to exceed 50 lbf (220 N) at points as
20、listed in 5.2.1 until the latch clears the strike. Requirements 50 lbf max. (220 N) For all measurement points 5.2.4 Key Cylinder Operation Test Measure the torque to lock and unlock the deadbolt (alarm set) by key from the inside of the door. Also, test the key torque from the outside of the door i
21、f the outside key option is provided with the exit lock. Repeat the operation five times and average the results. The average torque shall not exceed the limits specified. Requirements Maximum: 12 lbf-in (1.36 Nm) 5.2.5 Outside Pull Test A pull force as listed below shall be exerted on the door appr
22、oximately 3 in. (76 mm) from the latch edge and 40 in. (1020 mm) from the floor in an effort to pull the door open. The door shall not open and the device shall function after release of the force. Requirements Pull force: 1200 lbf (5340 N) 5.3 Tests for Alarms 5.3.1 Cycle Test for Alarms Cycle the
23、alarm 1,000 times. A cycle consists of actuating the alarm and resetting the alarm per the intended operation. If battery powered, the batteries are permitted to be replaced during the test as required. Requirements All the alarm features shall function as intended at the end of 1000 cycles. 5.3.2 S
24、lam Test With the alarm mounted on the slam test door fixture, adjust to provide no latching or locking engagement. Use a size 3 overhead door closer with standard arm mounting and all valves fully open. Door closing speed shall be 2.5 seconds or less from 90 degrees open to fully closed with no dec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIBHMAA156292017EXITLOCKSEXITALARMSALARMSFOREXITDEVICESPDF

链接地址:http://www.mydoc123.com/p-434270.html