1、Designation: F1817 17 An American National StandardStandard Test Method forPerformance of Conveyor Ovens1This standard is issued under the fixed designation F1817; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers an evaluation of the energyconsumption and cooking performance of conveyor ovens. Thefood service ope
3、rator can use this evaluation to select aconveyor oven and understand its energy consumption.1.2 This test method is applicable to gas and electricconveyor ovens.1.3 The conveyor oven can be evaluated with respect to thefollowing (where applicable):1.3.1 Energy input rate and thermostat calibration
4、(see10.2),1.3.2 Preheat energy consumption and time (see 10.3),1.3.3 Idle energy rate (see 10.4),1.3.4 Pilot energy rate (if applicable) (see 10.5), and1.3.5 Cooking energy efficiency and production capacity(see 10.6).1.4 The values stated in inch-pound units are to be regardedas standard. No other
5、units of measurement are included in thisstandard.1.5 This test method may involve hazardous materials,operations, and equipment. This standard does not purport toaddress all of the safety concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish app
6、ropriate safety, health, and environmental prac-tices and determine the applicability of regulatory limitationsprior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDev
7、elopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASHRAE Documents:22013 ASHRAE Handbook of Fundamentals Chapter 1, Psy-chrometrics2014 ASHRAE HandbookRefrigeration Chapter 19
8、Ther-mal Conductivity of Foods, page 9 (R19.9); Diffusivity offoods, R19.17, and Enthalpy of foods R19.8ASHRAE Guideline 2-1986 (RA90) Engineering Analysisof Experimental DataASHRAE Guideline 2 2010 (RA 2014) Engineering Analy-sis of Experimental Data2.2 Other Document:AOAC Procedure 984.25 Moisture
9、 (Loss of Mass on Dry-ing) in Frozen French Fried Potatoes33. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 chamber stabilization pizzas, nfull cooking cavityload of nominal 12 in. pizzas loaded at beginning of productioncapacity test.3.1.2 conveyor oven, nan appliance that car
10、ries the foodproduct on a moving conveyor into and through a heatedchamber. The chamber may be heated by gas or electric forcedconvection, radiant, or quartz tubes. Top and bottom heat maybe independently controlled.3.1.3 cooking energy effciency, nquantity of energy im-parted to the specified food
11、product, expressed as a percentageof energy consumed by the conveyor oven during the cookingevent.3.1.4 cooking energy rate, naverage rate of energy con-sumption (Btu/h or kW) during the cooking energy efficiencytests.3.1.5 cooking stabilization pizzas, nfull cooking chamberof nominal 12 in. pizzas
12、continuously loaded directly followingthe test pizzas. Pizzas keep the cooking chamber consistentduring the measured test pizzas.1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energ
13、y Protocol.Current edition approved April 1, 2017. Published November 2017. Originallyapproved in 1997. Last previous edition approved in 2009 as F1817 09. DOI:10.1520/F1817-17.2Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circ
14、le, NE, Atlanta, GA30329.3Available from AOAC International, 2275 Research Blvd., Suite 300,Rockville, MD 20850-3250, http:/www.aoac.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accor
15、dance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.1.6 energy input rate, npeak r
16、ate at which a conveyoroven consumes energy (Btu/h or kW).3.1.7 idle energy rate, nthe conveyor ovens rate ofenergy consumption (kW or Btu/h), when empty, required tomaintain its cavity temperature at the specified thermostat setpoint.3.1.8 oven cavity, nthat portion of the conveyor oven inwhich foo
17、d products are heated or cooked.3.1.9 pilot energy rate, nrate of energy consumption(Btu/h) by a conveyor ovens continuous pilot (if applicable).3.1.10 preheat energy, namount of energy consumed (Btuor kWh), by the conveyor oven while preheating its cavityfrom ambient temperature to the specified th
18、ermostat set point.3.1.11 preheat time, ntime (min.) required for the con-veyor oven cavity to preheat from ambient temperature to thespecified thermostat set point.3.1.12 production capacity, nmaximum rate (lb/h) atwhich a conveyor oven can bring the specified food product toa specified “cooked” co
19、ndition.3.1.13 production rate, nrate (lb/h) at which a conveyoroven brings the specified food product to a specified“ cooked”condition. Does not necessarily refer to maximum rate. Pro-duction rate varies with the amount of food being cooked.3.1.14 test pizzas, nfull cooking chamber of nominal 12in.
20、 pizzas continuously loaded directly following the stabiliza-tion load. These are the pizzas measured for productioncapacity.3.1.15 uncertainty, nmeasure of systematic and precisionerrors in specified instrumentation or measure of repeatabilityof a reported test result.4. Summary of Test Method4.1 A
21、ccuracy of the conveyor oven thermostat is checked ata setting of 475F (246C) and the thermostat is adjusted asnecessary.4.2 Energy Input RateDetermined to confirm that theconveyor oven is operating within 5 % of the nameplate energyinput rate. For gas conveyor oven, the pilot energy rate and thefan
22、 and control energy rates are also determined. The input rateof the oven is determined to check whether the oven isoperating properly. If the measured input rate is not within 5 %of the rated input, all further testing ceases until the appliancecan be made to operate within this specification. For g
23、as ovens,the pilot energy rate and the fan and control energy rate are alsodetermined.4.3 Preheat Energy Consumption and TimeThe time andenergy required to preheat the oven from room temperature 756 5F (24 6 2.8C) to 475 6 5F (246 6 2.8C) determined.4.4 Idle Energy RateThe idle energy rate (kBtu/h o
24、r kW)is determined with the oven set to maintain 475 6 5F (246 62.8C).4.5 Cooking energy efficiency and production rate aredetermined during heavy-load cooking tests using pizza as afood product.4.6 Cooking UniformityThe uniformity of heating withinthe ovens cavity is determined and reported based o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF18172017STANDARDTESTMETHODFORPERFORMANCEOFCONVEYOROVENSPDF

链接地址:http://www.mydoc123.com/p-432925.html