ANSI ASTM F1804-2008 Standard Practice for Determining Allowable Tensile Load for Polyethylene (PE) Gas Pipe During Pull-In Installation《沿路安装过程聚乙烯(PE)煤气管的许可拉伸载荷测定用规程》.pdf
《ANSI ASTM F1804-2008 Standard Practice for Determining Allowable Tensile Load for Polyethylene (PE) Gas Pipe During Pull-In Installation《沿路安装过程聚乙烯(PE)煤气管的许可拉伸载荷测定用规程》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F1804-2008 Standard Practice for Determining Allowable Tensile Load for Polyethylene (PE) Gas Pipe During Pull-In Installation《沿路安装过程聚乙烯(PE)煤气管的许可拉伸载荷测定用规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1804 08 (Reapproved 2016) An American National StandardStandard Practice forDetermining Allowable Tensile Load for Polyethylene (PE)Gas Pipe During Pull-In Installation1This standard is issued under the fixed designation F1804; the number immediately following the designation indicates
2、 the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides a means to determine an
3、allow-able tensile load (ATL) value for a polyethylene gas pipe thatis to be installed underground using methods that pull the pipeinto a trench (cut or plowed), bore hole, casing pipe, or the like.The ATL value takes into account pipe size, tensile yeildstrength, pipe temperature, and pulling load
4、duration.1.2 The ATL is used to set the break-away strength for a“weak-link” device, or as a limit setting for other devices thatcontrol the maximum pulling force exerted by equipment usedto pull polyethylene gas pipe into an underground location, orto determine if pulling equipment can extert pulli
5、ng forcegreater than the ATL value for the gas pipe being installed. Aweak-link device is installed where the pipe pulling equipmentis connected to the polyethylene gas pipe. If pulling loadexceeds the ATL limit, the device de-couples the pipe from thepulling equipment. Other measures or equipment t
6、hat limit thepulling force on the pipe are also used. When the ATL value iscompared to the pulling force developed by the pull-in instal-lation equipment and equipment cannot extert pulling forcegreater than the ATL value, a weak-link or other device forlimiting the pulling force is not necessary.1.
7、3 This practice does not address weak-link device designor requirements, nor does it address the design or requirementsfor other equipment or procedures used to limit the pullingforce applied to polyethylene gas pipe during pull-in installa-tion.1.4 This practice does not address installation method
8、s orprocedures employed for pull-in of polyethylene gas pipe.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.6 This standard does n
9、ot purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standar
10、ds:2D638 Test Method for Tensile Properties of PlasticsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD2513 Specification for Polyethylene (PE) Gas PressurePipe, Tubing, and FittingsF412 Terminology Relating to Plastic Piping Systems3. Terminology3.1 Unless otherwise indicated, abbrevia
11、tions are in accor-dance with Terminology D1600, and terms are in accordancewith Terminology F412.3.2 allowable tensile load (ATL), nThe maximum tensileload applied to a polyethylene gas pipe during pull-in instal-lation that does not result in an unrecoverable tensile elonga-tion of the pipe.NOTE 1
12、Polyethylene gas pipe materials are visco-elastic, that is, theyexhibit properties associated with both elastic materials such as rubber,and viscous materials such as wax or clay. When subjected to a tensileload that is significant, but less than the yield strength, polyethylene willelongate or stre
13、tch. If the load is then removed, polyethylene will, overtime, recover all or part of the elongation, depending upon the magnitudeof the load, and the length of time the load was applied. For the purposesof this practice, elongation that is not completely recovered in about 24 hafter the load is rel
14、eased, is considered unrecoverable.4. Significance and Use4.1 The ATL value is used to set the break-away strength ofa weak-link device, or to set other equipment used to limitpulling force during pull-in installation of polyethylene gaspipe, or to determine if pulling equipment can extert pullingfo
15、rce greater than the ATL value for the polyethylene gas pipebeing installed.1This practice is under the jurisdiction of Committee F17 on Plastic PipingSystems and is the direct responsibility of Subcommittee F17.60 on Gas.Current edition approved Nov. 1, 2016. Published November 2016. Originallyappr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF18042008STANDARDPRACTICEFORDETERMININGALLOWABLETENSILELOADFORPOLYETHYLENEPEGASPIPEDURINGPULLININSTALLATION

链接地址:http://www.mydoc123.com/p-432920.html