ANSI ASTM D2519-2007 Standard Test Method for Bond Strength of Electrical Insulating Varnishes by the Helical Coil Test《用螺旋线圈试验测定电绝缘清漆粘结强度的试验方法》.pdf
《ANSI ASTM D2519-2007 Standard Test Method for Bond Strength of Electrical Insulating Varnishes by the Helical Coil Test《用螺旋线圈试验测定电绝缘清漆粘结强度的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D2519-2007 Standard Test Method for Bond Strength of Electrical Insulating Varnishes by the Helical Coil Test《用螺旋线圈试验测定电绝缘清漆粘结强度的试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2519 07 (Reapproved 2012)Standard Test Method forBond Strength of Electrical Insulating Varnishes by theHelical Coil Test1This standard is issued under the fixed designation D2519; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This te
3、st method covers determination of the bondstrength of an electrical insulating varnish when applied to ahelical coil. The helical coil can be made from bare aluminumor copper wire or from film or fiber-insulated magnet wire.Helical coils made from bare aluminum or bare copper wirewill yield values o
4、f bond strength for the varnish when appliedto bare metal conductors. The use of film or fiber-insulatedmagnet wire will show values for that particular combinationof insulation and varnish.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for i
5、nformationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.
6、 See Section 7.2. Referenced Documents2.1 ASTM Standards:2D115 Test Methods for Testing Solvent Containing Var-nishes Used for Electrical InsulationD1711 Terminology Relating to Electrical InsulationD6054 Practice for Conditioning Electrical Insulating Mate-rials for Testing (Withdrawn 2012)3E691 Pr
7、actice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 For definitions of other terms relating to electricalinsulation, see Terminology D1711.3.1.2 bond strengtha measure of the force required toseparate surfaces which have been b
8、onded together.3.2 Definitions of Terms Specific to This Standard:3.2.1 event timethe time between initial application of aphysical or electrical stress and failure of the specimen undertest.3.2.2 response timethe time required for an indicating orrecording device to react to change in stress on a s
9、pecimenunder test.4. Summary of Test Method4.1 Flexural strength tests are made on varnish-treatedhelical coils to determine the force required to break the coilunder specified conditions.5. Significance and Use5.1 Values obtained by flexural tests can provide informa-tion with regard to the bond st
10、rength of the particular varnish,in combination with a particular wire, when measured underconditions described in this test method.6. Apparatus6.1 Tensile Testing MachineUse an adjustable-speed driveand a suitable instrument for measuring force to break thespecimen. Available tensile testing machin
11、es or an accuratespring gauge and a separate adjustable-speed drive are suitable.To cover the range of load strength values which are commonlyencountered it is recommended that a multirange tester beused.6.1.1 It has been found that gages rated 5, 25, 150, and500 N (1, 5, 30, and 100 lbf) are adequa
12、te to cover the range ofvarnishes.6.2 Test FixtureThe test fixture consists of two rollers,attached to a common frame, and a 90 V-block. One part,either the rollers or the V-block, is held stationary while theother part is moved. No friction contact which will affect this1This test method is under t
13、he jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.01 on Electrical Insulating Varnishes, Powders and Encapsulat-ing Compounds.Current edition approved April 1, 2012. Published April 2012. Originallyapproved in 1
14、966. Last previous edition approved in 2007 as D2519 07. DOI:10.1520/D2519-07R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page
15、 onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1movement is allow
16、ed. The general shape and the relativeposition of these parts are shown in Fig. 1. The rollers have adiameter of 9.5 mm (0.375 in.) at the center and are parallelhaving a center-to-center distance of 44.5 mm (1.75 in.). The90 V-block has a radius at the apex of 0.8 mm (0.03 in.).6.3 Test Fixture Enc
17、losureFor tests at other than roomtemperature, use an insulated heat-resistant enclosure, designedto fit around the test fixture and connected to the tension testingmachine. This enclosure permits a frictionless connectionbetween the test fixture and the instrument that measures thebreaking force. T
18、he enclosure is designed with a suitablelocation for holding six or more specimens. It is heated orcooled by a separate source of uniformly circulating hot or coldair. The temperature control system is capable of returning thetest specimens and the chamber to the test temperature in lessthan 10 min.
19、 A thermostatic control, with the measuringthermocouple located within 25 mm (1.0 in.) of the center ofthe coil being tested, is set to maintain the temperature of thechamber to within 6 2C of the desired temperature after thetemperature has stabilized.7. Safety Precautions7.1 It is unsafe to use va
20、rnish at temperatures above theflash point without adequate ventilation, especially if thepossibility exists that flames or sparks are present. Storevarnish in sealed containers.8. Test Specimens8.1 The test specimens are 75 mm (3 in.) long coils of No.18 AWG wire, cut from a helix of convenient len
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD25192007STANDARDTESTMETHODFORBONDSTRENGTHOFELECTRICALINSULATINGVARNISHESBYTHEHELICALCOILTEST

链接地址:http://www.mydoc123.com/p-432287.html