1、ANSI/ANS-40.37-2009mobile low-level radioactivewaste processing systemsANSI/ANS-40.37-2009This standard has been reviewed and reaffirmed with the recognition that it may reference other standards and documents that may have been superseded or withdrawn. The requirements of this document will be met
2、by using the version of the standards and documents referenced herein. It is the responsibility of the user to review each of the references and to determine whether the use of the original references or more recent versions is appropriate for the facility. Variations from the standards and document
3、s referenced in this standard should be evaluated and documented. This standard does not necessarily reflect recent industry initiatives for risk informed decision-making or a graded approach to quality assurance. Users should consider the use of these industry initiatives in the application of this
4、 standard. REAFFIRMED June 30, 2016 ANSI/ANS-40.37-2009; R2016 ANSI/ANS-40.37-2009American National StandardMobile Low-Level RadioactiveWaste Processing SystemsSecretariatAmerican Nuclear SocietyPrepared by theAmerican Nuclear SocietyStandards CommitteeWorking Group ANS-40.37Published by theAmerican
5、 Nuclear Society555 North Kensington AvenueLa Grange Park, Illinois 60526 USAApproved November 20, 2009by theAmerican National Standards Institute, Inc.AmericanNationalStandardDesignation of this document as an American National Standard attests thatthe principles of openness and due process have be
6、en followed in the approvalprocedure and that a consensus of those directly and materially affected bythe standard has been achieved.This standard was developed under procedures of the Standards Committee ofthe American Nuclear Society; these procedures are accredited by the Amer-ican National Stand
7、ards Institute, Inc., as meeting the criteria for AmericanNational Standards. The consensus committee that approved the standardwas balanced to ensure that competent, concerned, and varied interests havehad an opportunity to participate.An American National Standard is intended to aid industry, cons
8、umers, gov-ernmental agencies, and general interest groups. Its use is entirely voluntary.The existence of an American National Standard, in and of itself, does notpreclude anyone from manufacturing, marketing, purchasing, or using prod-ucts, processes, or procedures not conforming to the standard.B
9、y publication of this standard, the American Nuclear Society does not insureanyone utilizing the standard against liability allegedly arising from or afterits use. The content of this standard reflects acceptable practice at the time ofits approval and publication. Changes, if any, occurring through
10、 developmentsin the state of the art, may be considered at the time that the standard issubjected to periodic review. It may be reaffirmed, revised, or withdrawn atany time in accordance with established procedures. Users of this standardare cautioned to determine the validity of copies in their pos
11、session and toestablish that they are of the latest issue.The American Nuclear Society accepts no responsibility for interpretations ofthis standard made by any individual or by any ad hoc group of individuals.Requests for interpretation should be sent to the Standards Department atSociety Headquart
12、ers. Action will be taken to provide appropriate response inaccordance with established procedures that ensure consensus on theinterpretation.Comments on this standard are encouraged and should be sent to SocietyHeadquarters.Published byAmerican Nuclear Society555 North Kensington AvenueLa Grange Pa
13、rk, Illinois 60526 USACopyright 2009 by American Nuclear Society. All rights reserved.Any part of this standard may be quoted. Credit lines should read “Extracted fromAmerican National Standard ANSI0ANS-40.37-2009 with permission of the publisher,the American Nuclear Society.” Reproduction prohibite
14、d under copyright conventionunless written permission is granted by the American Nuclear Society.Printed in the United States of AmericaForewordThis Foreword is not a part of American National Standard “Mobile Low-Level Radio-active Waste Processing Systems,” ANSI0ANS-40.37-2009.!A key aspect for th
15、e further development of nuclear technology is the effectivemanagement of low-level radioactive wastesLLWs! generated during the facilityoperation. Fundamental to the effective management of radioactive wastes is thedesign, construction, and operation of radioactive waste processing systems. Thissta
16、ndard was originally issued in 1993 in response to interest in the use ofmobile radioactive waste processing systems that could be transported fromfacility to facility, retained in service at a facility for an extended period of timeor quickly replaced by alternate treatment technology. In 2001, the
17、 U.S. NuclearRegulatory Commission NRC! cited this standard for mobile treatment systemsin Rev. 2 of Regulatory Guide 1.143 RG 1.143!. The NRC also granted designrelief in Rev. 2 of RG 1.143 when it allowed Power Piping ANSI0ASME B31.1!versus Process Piping ANSI0ASME B31.3! to be used for radioactiv
18、e wastesystems.Unfortunately, this standard failed to be reaffirmed in 2003. This standard isbeing reissued to incorporate the design relief granted by the NRC in 2001 andto service continued operation at nuclear facilities and new nuclear facilityconstruction.It is the purpose of this standard to p
19、rovide requirements for the design and op-eration of the mobile low-level radioactive waste processingMRWP! system. It isthe intent of this standard to identify a basis for establishing uniform practicesand minimum requirements for the design, fabrication, and operation of MRWPsystems as applied to
20、nuclear facility operations e.g., power plants, institutions,and laboratories that generate wastes approved for disposal at 10 CFR 61 LLWdisposal sites!. This standards scope does not address systems used to processwaste from nuclear facilities that potentially contain fissile material in sufficient
21、quantities to require controls to avoid criticality; i.e., ANSI0ANS-40.37-2009 re-quirements do not address wastes containing quantities of fissile or long-lived ra-dionuclides that are classified as high-level or transuranic radioactive waste atypicalof NRC-licensed commercial facilities and beyond
22、 the scope of 10 CFR 61. Systemsapplicable to non-low-level waste that use this standard might have to meet ad-ditional requirements beyond the scope of this standard. This standard addressesthe technical practices and requirements necessary for radioactive waste process-ing operations while maintai
23、ning consideration for reducing radiation exposuresto the environment, the public, and facility operating personnel.This standard might reference documents and other standards that have beensuperseded or withdrawn at the time the standard is applied. A statement hasbeen included in the references se
24、ction that provides guidance on the use ofreferences.This standard does not incorporate the concepts of generating risk-informedinsights, performance-based requirements, or a graded approach to quality as-surance. The user is advised that one or more of these techniques could enhancethe application
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIANS40372009MOBILELOWLEVELRADIOACTIVEWASTEPROCESSINGSYSTEMS 移动 放射性 废弃物 处理 系统 PDF

链接地址:http://www.mydoc123.com/p-430931.html