ANSI American Society of Sanitary Engineering 1051-2009 Performance Requirements for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems.pdf
《ANSI American Society of Sanitary Engineering 1051-2009 Performance Requirements for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems.pdf》由会员分享,可在线阅读,更多相关《ANSI American Society of Sanitary Engineering 1051-2009 Performance Requirements for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems 1ASSE Standard 1051 - 2009Performance Requirements forIndividual and Branch Type Air Admittance Valves for Sanitary Drainage Systems American Society of Sanitary EngineeringASSE Standard #1051-2009ASSE Board Approved: May
2、, 2009 ANSI Approved: January, 2010An American National StandardIndividual and Branch Type Air Admittance Valves for Sanitary Drainage Systems iASSE Standard 1051 - 2009American Society of Sanitary EngineeringWestlake, OhioCopyright 2009, 2002, 1996 1990All rights reserved.Neither this standard, nor
3、 any portion thereof, may be reproduced without the written consent of the American Society of Sanitary Engineering.No product may be said to be ASSE approved unless the manufacturer has applied to the ASSE, has had his product tested according to the applicable ASSE standards, and when the product
4、has passed the test, displays the ASSE Seal on the product.Instructions for receiving the authorization to display the ASSE Seal are available from ASSEs International Office. Organizations wishing to adopt or list any ASSE standard should print the ASSE standard number on the cover page first and i
5、n equal or larger type to that of the adopting or listing organization.General Informationii Individual and Branch Type Air Admittance Valves for Sanitary Drainage SystemsASSE Standard 1051 - 2009Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems iiiASSE Standard 1051 - 2
6、009This foreword shall not be considered a part of the standard, however, it is offered to provide background information.ASSE standards are developed in the interest of consumer safety.ASSE considers product performance standards to be of great value in the development of improved plumbing systems.
7、This standard focuses on devices known as AAVs. These devices are intended as an alterna-tive to vents for individual fixtures and branches in the plumbing drainage system. The working group which developed this standard revision, was set up within the framework of the Product Standards Committee of
8、 the American Society of Sanitary Engineering.Recognition is made of the time volunteered by members of this working group and of the support of the manufacturers who also participated in the meetings for this standard.This standard does not imply ASSEs endorsement of a product which conforms to the
9、se requirements.Compliance with this standard does not imply acceptance by any code body.It is recommended that these devices be installed consistent with local codes by qualified and trained professionals.This standard was promulgated in accordance with procedures developed by the American National
10、 Standards Institute (ANSI).Forewordiv Individual and Branch Type Air Admittance Valves for Sanitary Drainage SystemsASSE Standard 1051 - 2009Edward J. LyczkoProduct Standards Committee ChairmanCleveland ClinicCleveland, OhioRand H. AckroydRand Technical Consulting, LLCNewburyport, MassachusettsWill
11、iam Briggs, Jr.MGJ Associates New York, New YorkJudson W. CollinsJULYCO ProfessionalsMannford, OklahomaA. Richard EmmersonGeneral InterestBuffalo Grove, IllinoisRon GeorgeRon George Design they only allow air to enter the system. These devices are designed to be used for individual fixtures or for a
12、 horizontal branch serving multiple fixtures. When these devices are installed in a building, there shall be at least one (1) open vent terminal to relieve positive pressure which extends to the atmosphere outside of the building serving the building drain on which these devices are installed.1.2 Sc
13、ope1.2.1 DescriptionThese devices consist of a one-way valve designed to allow air to enter the plumbing drainage system when a pressure less than atmospheric develops. The device closes and seals by grav-ity under (0) differential pressure (static condition) and under positive pressure. These devic
14、es prevent sewer gases from entering the building. The device consists of a hooded or shielded body which contains a movable sealing assembly which seats and seals air flow when closed and allows air to enter when open.1.2.2 Temperature RangeThese devices shall function at temperatures from -40.0F t
15、o 150.0F (-40.0C to 65.6C).1.2.3 RatingThese devices shall be rated to pass the air rate indicated in Table 1 without exceeding a pres-sure drop greater than 1.0 inch (25.4 mm) of water column.Table 1Drainage Pipe Size Maximum DFUsAirflow RateIPS DN CFM L/sinch mm1 32 1 1 0.471 40 3 1 0.472.0 50 6 2
16、 0.943.0 75 20 4 1.884.0 100 160 8 3.762 Individual and Branch Type Air Admittance Valves for Sanitary Drainage SystemsASSE Standard 1051 - 20091.3 Construction1.3.1 Air Inlet ShieldsAir inlets of the device shall be shielded to prevent inlet fouling. Air inlet shields shall extend down the body of
17、the device, over the sealing membrane, to the lowest portion of the sealing membrane, and shall maintain a minimum of 1/16 inch (1.6 mm) clearance between the inner lower edge of the shield and the lowest surface of the air opening of the sealing membrane.1.3.2 LeakageThe device and joining methods
18、shall not permit air leakage when pressurized up to 30 inches (762.0 mm) water column.1.3.3 InterferenceThe end connection of the device shall be designed so that when installed, the joint shall not interfere with any moving parts of the device or restrict air passageways.1.3.4 Connections1.3.4.1 Th
19、reads for AAVsFor all plastic devices having taper pipe threads for connection to the drainage system, threads shall conform to the requirement of ASTM Specification F 1498. Metallic threads shall conform to the requirements of ASME B1.20.1.1.3.4.2 Hubless ConnectorsHubless connectors shall comply w
20、ith ASTM C-564(3), CSA B602(4), or FM 168(5).1.3.4.3 Dimensions and Tolerances for AAV SocketsSockets on the device shall conform to the applicable material requirements. Devices having sockets for connection made from ABS material shall conform to the requirements of ASTM Specification D 2661, with
21、 the exception of wall thickness. Devices having sockets made from PVC material shall conform to the requirements of ASTM Specification D 2665, with the excep-tion of wall thickness.1.3.4.4 Other ConnectionsWhere types of connections other than connections specified in Sections 1.3.4.1, 1.3.4.2, and
22、 1.3.4.3 are provided with the device, the connection shall meet the applicable material require-ments and the total assembly shall comply with the performance tests in this standard.1.4 Reference StandardsReferences to industry standards shall mean the latest edition.Individual and Branch Type Air
23、Admittance Valves for Sanitary Drainage Systems 3ASSE Standard 1051 - 2009Section II2.0 Test Specimens2.1 Samples SubmittedThree (3) devices of each size and model shall be submitted by the manufacturer. Tests shall be performed in the order listed on one (1) device of each size submitted.2.2 Sample
24、s TestedThe testing agency shall select one (1) of each type or model and size for full test.2.3 DrawingsAssembly drawings, installation drawings and other data which are needed to enable a test-ing agency to determine compliance with this standard shall accompany devices submitted for examination a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAMERICANSOCIETYOFSANITARYENGINEERING10512009PERFORMANCEREQUIREMENTSFORINDIVIDUALANDBRANCHTYPEAIRADMITTANCEVALVESFORSANITARYDRAINAGESYSTEMSPDF

链接地址:http://www.mydoc123.com/p-430862.html