1、 4301 NORTH FAIRFAX DRIVE ARLINGTON, VIRGINIA 22203 2001 STANDARD for REFRIGERANT PRESSURE REGULATING VALVES Standard 770 Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Pr
2、ice $15.00 (M) $30.00 (NM) Copyright 2001, by Air-Conditioning and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTANT SAFETY RECOMMENDATIONS It is strongly recommended that the product be designed, constructed, assembled and installed in accordan
3、ce with nationally recognized safety requirements appropriate for products covered by this standard. ARI, as a manufacturers trade association, uses its best efforts to develop standards employing state-of-the-art and accepted industry practices. However, ARI does not certify or guarantee safety of
4、any products, components or systems designed, tested, rated, installed or operated in accordance with these standards or that any tests conducted under its standards will be non-hazardous or free from risk. Note: This standard supersedes ARI Standard 770-94. Copyright Air-Conditioning and Refrigerat
5、ion Institute Provided by IHS under license with ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE OF CONTENTS SECTION PAGE Section 1. Purpose .1 Section 2. Scope 1 Section 3. Definitions 1 Section 4. Test Requirements2 Section 5. Rating Requirements 2 Secti
6、on 6. Minimum Data Requirements for Published Ratings.2 Section 7. Marking and Nameplate Data.3 Section 8. Conformance Conditions3 APPENDICES Appendix A. References - Normative4 Appendix B. References - Informative 4 Appendix C. Method of Testing for Rating Refrigerant Pressure Regulating Valves - N
7、ormative5 TABLES FOR APPENDICES Table C1. Pressure-Tap Hole Diameters and Lengths 8 Table C2. Specific Heat Ratios (k)14 FIGURES FOR APPENDICES Figure C1. Typical System Piping for Pressure Regulating Valve Liquid Flow Test .6 Figure C2. Typical System Piping for Pressure Regulating Valve Gas Flow T
8、est7 Figure C3. Mass Flow Rate vs. Density C Pressure Drop.11 Figure C4. KA vs. Acoustic Ratio.13 Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Air-Conditioning
9、 and Refrigeration Institute Provided by IHS under license with ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ARI STANDARD 770-2001 1 REFRIGERANT PRESSURE REGULATING VALVES Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish, for Refri
10、gerant Pressure Regulating Valves: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineer
11、s, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to Refrigerant Pressure Regulating Valves controlling Volatile Refrigerant flow that primarily respond to press
12、ure. The types of Refrigerant Pressure Regulating Valves are those that are responsive to inlet, to outlet, or to differential pressures sensed locally or remotely. 2.2 Exclusions. Excluded from this standard are Automatic Expansion Valves and devices used with: a. Automotive and recreational vehicl
13、e air-conditioning b. Household refrigerating units c. Room air-conditioners Section 3. Definitions All terms in this document shall follow the standard industry definitions in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unless otherwise defi
14、ned in this section. 3.1 Bubble Point. Refrigerant liquid saturation temperature at a specified pressure. 3.2 Dew Point. Refrigerant vapor saturation temperature at a specified pressure. 3.3 Gradient. The change in controlled pressure required to move the Refrigerant Pressure Regulating Valve closur
15、e member from its opening point to its standard rated capacity, psi kPa. In some types of pilot-operated controllers, the Gradient could be essentially zero. 3.4 Main. Tubing or piping by which the Refrigerant Pressure Regulating Valve is connected to the apparatus. 3.5 Pressure Drop. The pressure d
16、ifference between the Refrigerant Pressure Regulating Valve inlet and the Refrigerant Pressure Regulating Valve outlet, with the main port (orifice) open, psi kPa. 3.6 Published Rating. A statement of the assigned values of those performance characteristics under stated Rating Conditions, by which a
17、 Refrigerant Pressure Regulating Valve may be chosen to fit its application. These values apply to all Refrigerant Pressure Regulating Valves of like nominal size and type produced by the same manufacturer. As used herein, the term Published Rating includes the rating of all performance characterist
18、ics shown on the Refrigerant Pressure Regulating Valve or published specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.6.1 Application Rating. A rating based on tests performed at Application Rating conditions (other than Standard Rating Co
19、nditions). 3.6.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.7 Rating Conditions. Any set of operating conditions under which a single level of performance results, and which cause only that level of performance to occur. 3.7.1 Standard Rating Conditions. Rati
20、ng Conditions used as the basis of comparison for performance characteristics. 3.8 Refrigerant Pressure Regulating Valve. A self or pilot-operated controller in which the energy to position the Refrigerant Pressure Regulating Valve closure member is provided by the pressure of the controlled refrige
21、rant, sensed locally or remotely. 3.8.1 Differential Pressure Regulating Valve. A valve which opens or closes in response to a difference in pressure between the inlet and outlet, sensed locally or remotely. 3.8.2 Downstream Pressure Regulating Valve. A valve which opens or closes in response to a c
22、hange in outlet pressure, sensed locally or remotely. 3.8.3 Upstream Pressure Regulating Valve. A valve which opens or closes in response to a change in inlet pressure, sensed locally or remotely. Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARINot for Re
23、saleNo reproduction or networking permitted without license from IHS-,-,-ARI STANDARD 770-2001 2 3.8.4 Valve Closure Member. The part of a valve which is positioned to close, open or modulate the flow through the valve port(s). 3.9 Refrigerant Pressure Regulating Valve Capacity. The mass flow rate o
24、f a fluid through the Refrigerant Pressure Regulating Valve, expressed in suitable units for the application and based on specific conditions. 3.10 Set Point. A predetermined pressure which the Refrigerant Pressure Regulating Valve is set to maintain, psi kPa. 3.11 “Shall“ or “Should.“ “Shall“ or “s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARI7702001REFRIGERANTPRESSUREREGULATINGVALVES 制冷 压力 调节 PDF

链接地址:http://www.mydoc123.com/p-429464.html