1、 Comments, suggestions, or questions on this document should be addressed to: AFLCMC/WNZE, Robins AFB GA 31098-1813. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.,mil. AMSC N/A FSC 6625 DIS
2、TRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. INCH-POUND A-A-59937 13-Dec-2013 COMMERCIAL ITEM DESCRIPTION REFLECTOMETER, METALLIC TIME DOMAIN The General Services Administration has authorized the use of this Commercial Item Description for all federal agencies. 1.
3、SCOPE. This Commercial Item Description (CID) describes a Metallic Time Domain Reflectometer (herein know as Frequency Domain Reflectometer) for a Copper or Metallic Medium. The Metallic Time Domain Reflectometer is capable of locating faults, return loss, distance along any point of a cable or ante
4、nna system. This CID is meant as a minimum requirement for a Metallic Time Domain Reflectometer, and only those manufacturers that meet or surpass the following requirements are to supply the Metallic Time Domain Reflectometer per this CID. 2. CLASSIFICATION. The test set covered by this CID shall b
5、e commercially available equipment and may be modify to the extent necessary to meet the following description. The equipment shall be Class 3, in accordance with MIL-PRF-28800. The equipment shall be capable of operation within the accuracies, limits, and specifications herein. 3. SALIENT CHARACTER
6、ISTICS. 3.1 Item Description. These requirements describe a Frequency Domain Reflectometer for a Copper or Metallic Medium that shall be capable of locating faults, return loss, distance along any point of a cable or antenna system. 3.2 Frequency Range. The Frequency Domain Reflectometer shall be ca
7、pable of operating over a frequency range of 200 MHz to 3 GHz 3.3 Return Loss. The Frequency Domain Reflectometer shall have a return loss range of 0 to -60 dB. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59937 2 3.4 Input Impedance. The Freq
8、uency Domain Reflectometer shall have an input impedance of 50 . The instrument shall be able to cover other impedances with the use of matching impedance. This can be accomplished with the use of commercially available accessories that need to be provided with each instrument. 3.5 Near Instrument F
9、ault Detection. The Frequency Domain Reflectometer shall contain means to measure faults that are within 250 ft. or 76m of the instrument itself. 3.6 Input Measurement Signal. The Frequency Domain Reflectometer shall have the ability to accept input signals that is less or equal to +22 dBm. 3.7 Meas
10、urement Signal Immunity. The Frequency Domain Reflectometer shall capability to reject interfering signals that is less or equal to +13 dBm 3.8 Test Port. The Frequency Domain Reflectometer shall have a test connector in the form of a Type-N female connector. 3.9 Spectral Analysis Capability. The Fr
11、equency Domain Reflectometer shall contain spectral analysis capacity to examine the entire frequency range and able to find a tap, no matter where it is located. 3.10 Accessories. Accessories to be supplied by the manufacturer with each deliverable Frequency Domain Reflectometer shall include but n
12、ot limited to AC adapter (s), carrying case, user manual, and a traceable calibration certificate if required. 3.11 Interface. The Frequency Domain Reflectometer should be capable of interfacing with industry standard data interchangeable formats for files, format, storage, communication, plotting i
13、ncluding but not limited to USB, RS-232, N-Type connector. 3.12 Battery. The Frequency Domain Reflectometer shall have a rechargeable battery for use when it is not connected to main power or external charge source that provides a minimum of 3 Hours operating time. The Frequency Domain Reflectometer
14、 must meet the full performance and accuracy requirements of the instrument when operating on battery. A fully discharge battery shall take up to 4 Hours to recharge to 100% level and an automatic protective device shall be included to prevent overcharging the batteries. 3.13 Eletrical Power Sources
15、. The equipment power consumption of all components combined shall not exceed 400 watt and the Frequency Domain Reflectometer shall operate from nominal commercial military and shipboard/ flight power source over the ranges: 120Vrms ( 10% tolerance) at frequencies of 50 Hz, 60 Hz single-phase ( 5% t
16、olerance), and 220/240 Vrms at 50 Hz, 60 Hz single-phase as outlined in MIL-PRF-28800 paragraph 3.5.1. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59937 3 3.14 Design and Construction. The Frequency Domain Reflectometer shall be design and co
17、nstructed for commercial use and shall meet the definition of Commercial Off-The-Shelf (COTS) items in FAR 2.101 The Frequency Domain Reflectometer shall be designed and constructed in accordance with all applicable European Union (EU) requirements in order to have the “CE” marking affixed, Internat
18、ional Organization for Standardization (ISO), the International Electro-technical Commission (IEC), the International Telecommunication Union (ITU), Underwriters Laboratories (UL) and the American National Standards Institute (ANSI). It shall be designed and constructed so that no parts will work lo
19、ose in service, and to withstand the strains, jars, vibrations, and other conditions incident to shipping, storage, installation, and service. 3.15 Noise. The design shall ensure that noise created by the Frequency Domain Reflectometer is compatible with the environment and minimize exposure of pers
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA599372013REFLECTOMETERMETALLICTIMEDOMAINPDF

链接地址:http://www.mydoc123.com/p-427209.html