1、Comments, suggestions, or questions on this document should be addressed to: AFLCMC/WNZEA, 235 BYRON ST STE 19A, Robins AFB GA 31098-1813. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil.
2、AMSC N/A FSC 6130 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. A-A-59916 30 October 2012 COMMERCIAL ITEM DESCRIPTION POWER SUPPLY, DIRECT CURRENT, PORTABLE 28.5 Volts Direct Current, 600 Amperes The General Services Administration has authorized the use of this C
3、ommercial Item Description for all federal agencies. 1. SCOPE. This Commercial Item Description (CID) describes a portable, direct current (DC) power supply, herein referred to as DCPS. The DCPS has a 28.5 volt DC, 600 Ampere (amp) output rating to provide ground power to aircraft and to provide por
4、table electrical power for avionics backshop maintenance and facility tasks. 2. SALIENT CHARACTERISTICS 2.1 Safety and environmental. The equipment shall meet all safety and environmental requirements as specified in National Fire Protection Association (NFPA) 70 National Electrical Code (NEC), ANSI
5、/IEEE C2 National Electrical Safety Code and the latest applicable National Electrical Manufacturers Association (NEMA) standards except as stated herein. 2.2 Component protection. All space in which work is performed during operation, service, and maintenance shall be free of hazardous protrusions,
6、 sharp edges, or other features which may cause injury to personnel. All rotating and reciprocating parts and all parts subject to high operational temperatures or subject to being electrically energized, that are of such nature or so located as to be hazardous to personnel, shall be guarded or insu
7、lated to eliminate the hazard. All wires, cables, tubes, and hoses shall be supported and protected to minimize chafing and INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59916 2 abrasion and shall be located so as to provide adequate
8、 clearance from moving parts and high operational temperatures. Grommets shall be provided wherever wires, cables, tubes, or hoses pass through bulkheads, partitions, or structural members. 2.3 Design and construction. The DCPS shall be a stand-alone, self-contained unit capable of converting three
9、phase 50 and 60 Hertz (Hz) Alternating Current (AC) electrical power into 28.5 volt Direct Current (DC) electrical power. The DCPS shall accept any power input specified herein; all DCPS operating power shall be derived from the input power source. The DCPS shall be constructed of modular and easily
10、 replaceable subassemblies and components wherever possible. The DCPS enclosure shall have doors or covers to provide access for maintenance, repair, and replacement of components and subassemblies. The DCPS design shall include the maximum use of UL recognized or listed components. The DCPS shall b
11、e designed and constructed in accordance with all applicable European Union (EU) requirements in order to have the “CE” marking affixed (see 2.6.1). The DCPS shall be able to withstand the strains, jars, vibrations, and other conditions indicative to shipping, storage, installation, and service. Add
12、itional features and capabilities shall be permitted unless otherwise prohibited by this document. 2.4 Foreign object damage (FOD). All loose metal parts, such as pins or connector covers, shall be securely attached to the DCPS with wire ropes or chains. “Dog tag“ style beaded chains shall not be pr
13、ovided. Removable panels, if provided, shall be attached with captive fasteners. Tire valve stem caps shall be made of plastic. 2.5 Materials, protective coatings, and finish. 2.5.1 Protective coatings. Materials that deteriorate when exposed to sunlight, weather, or operational conditions normally
14、encountered during the service life of the item shall not be used or shall have means of protection against such deterioration that does not prevent compliance with the performance requirements specified herein. Protective coatings that chip, blister, crack, peel or scale with age or extremes of cli
15、matic conditions or when exposed to heat shall not be used. Fasteners, handles, and fittings used in the assembly of the item shall also be primed and painted unless they are specifically designed to resist deterioration without paint. 2.5.1.1 Finish. The exterior finish color of the DCPS shall be G
16、ray, Color Number 26173 of FED-STD-595. 2.5.1.2 Exclusion of water. The design of the DCPS shall be such as to prevent water leaking into, or being driven into, any part of the DCPS interior when either in an operating or travelling configuration. All windows, doors, panels, covers, etc., shall be p
17、rovided with sealing arrangements such that the entry of water is minimized when these items are correctly closed. Particular care shall be taken to prevent wetting of equipment and heat and sound proofing materials. Sharp corners and recesses shall be avoided so that moisture and solid matter canno
18、t accumulate to initiate localized attack. Sealed floors with suitable drainage shall be provided for storage compartments, engine compartments, and other areas in the DCPS that could collect and retain water. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
19、IHS-,-,-A-A-59916 3 2.5.1.2.1 Fluid traps and faying surfaces. There shall be no fluid traps on the DCPS. Faying surfaces of all structural joints, except welded joints, shall be sealed to preclude fluid intrusion. 2.5.1.2.2 Ventilation. Ventilation shall be sufficient to prevent moisture retention
20、and buildup. 2.5.1.2.3 Drainage. Drain holes shall be provided to prevent collection or entrapment of water or other unwanted fluid in areas where exclusion is impractical. All designs shall include considerations for the prevention of water or fluid entrapment and ensure that drain holes are locate
21、d to effect maximum drainage of accumulated fluids. The number and location of drain holes shall be sufficient to permit drainage of all fluids when the unit is in a 5 degree incline in any plane. The minimum diameter of the drain holes shall be 0.25 inch. 2.6 Markings. Manufacturers standard markin
22、gs shall be used. 2.6.1 Identification and information plates. An identification plate in accordance with MIL-STD-130 shall be securely attached to the DCPS in a readily accessible location. The identification plate shall contain the following information: Nomenclature, part number, serial number, d
23、ate of manufacture, manufacturers name, Commercial and Government Entity (CAGE) code, date of warranty expiration, and National Stock Number (NSN). The DCPS and any of its components for which the Governments unit cost is more than $5,000, is serially managed, or the procuring agency determines is m
24、ission essential, shall have Unique Identification (UID) (also known as Item Unique Identification (IUID) information permanently affixed on or near the respective identification plate(s), marked in accordance with MIL-STD-130. UID information shall be included as both a bar code and human readable
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA599162012POWERSUPPLYDIRECTCURRENTPORTABLE285VOLTSDIRECTCURRENT600AMPERESPDF

链接地址:http://www.mydoc123.com/p-427204.html