1、 FSC 6625 Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data that may improve this document should be sent to 642 CBSG/GBEC, 460 Richard Ray Blvd, Suite 200, Robins AFB, GA 31098-1813. Since contact information can change, you may want to verify the c
2、urrency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/online/ . A-A-59865 03 May 2010 COMMERCIAL ITEM DESCRIPTION INSULATION TEST SET The General Services Administration has authorized the use of the Commercial Item Description (CID) for all federal agenc
3、ies. 1. SCOPE. This Commercial Item Description (CID), describes a describes an insulation test set, a portable, high-voltage leakage test set for electrical insulators, measures current leakage across insulation, not capacity current, indicates AC Volts and AC micro-amperes, provides complete analy
4、sis data of the measured insulation such as resistance, power factor and electrical breakdown strength. This CID is meant as a minimum requirement for an insulation test set in which only those manufacturers that meet or surpass the following requirements are qualified per this CID. 2. SALIENT CHARA
5、CTERISTICS. The equipment shall be capable of operation within the accuracies, limits, and specifications herein. 2.1 Classification. Equipment covered by this CID shall be commercially available equipment and may modified to the extent necessary to meet the following description. The equipment shal
6、l be Class 3, in accordance with MIL-PRF-28800. 2.2 Order of Precedence. In the event of a conflict between the text of this CID and the references cited herein (except for associated detail specifications, specification sheets or MS standards) the text of this CID shall take precedence. Nothing in
7、this CID, however, shall supersede applicable laws and regulations unless a specific exemption has been obtained. 2.3 Safety. The equipment shall be UL (Underwriters Laboratories) listed and approved and/or shall comply with the safety requirements of MIL-PRF-28800 for the classification stated here
8、in. 2.3.1. Leakage Current Protection. Protection shall be provided from leakage current in excess of 3.5 milli-amperes (ma) rms (AC and DC) from any accessible conductive parts of equipment (including control shafts with knobs broken or removed and recessed calibration or adjustment controls) to ei
9、ther pole of the power source for any position of the power switch(es). INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59865 2 2.4 Electrical Power Sources. The equipment shall operate from nominal commercial, and military power sourc
10、es of 110, 120 volts ac (10%) at line frequencies of 50 Hz to 400 Hz and 240 Vac (10%) at line frequencies of 50 Hz to 60 Hz. 2.4.1 Power Consumption. Maximum power consumption of all components combined shall not exceed 70 watts. 2.5 Dimensions and Weight. The equipment shall be no larger than: 4.0
11、 inches high, 9.0 inches wide, and 16 inches deep. The weight including all accessories (excluding manual) shall not exceed 20 lbs. 2.6 Options. 2.6.1 Reusable Pouch Or Container. An attached accessory pouch may be used for storage of all supplied accessories in lieu of front-cover storage. 2.7 Reli
12、ability. Reliability verification testing shall be in accordance with the requirements of MIL-PRF-28800 for the classification stated herein. 2.8 Calibration And Maintenance Adjustments. The design of the system shall provide for readily accessible calibration adjustments and maintenance adjustments
13、. These adjustments shall be provided by variable value components, which are adjustable, by the use of simple means. The calibration by substitution of selected components or parts is unacceptable unless specifically approved. The calibration adjustments, wherever possible, shall be accessible with
14、out removal of the instrument case or modules. 2.9 Performance Characteristics. The instrument shall meet all performance requirements specified herein. 2.9.1 Voltage. The voltage range shall be a minimum of 0-35 VDC in a dual or single range selectable from the front panel. 2.9.2 Operating Temperat
15、ure Range The equipment shall meet its performance and accuracy requirements in an operating environment of 0 C to 40 C. 2.9.3 Transient Response Time. The transient response time shall be less than 50 micro-seconds following change in output current from full load to half load for output to recover
16、 to within 15 milli-volts. 2.9.4 Load Effect. The load effect on the power supply shall be no greater than 0.01% + 5mV for load variation from 0 to full load. 2.9.9 Line effect. The line effect on the power supply shall not be greater than 0.01% + 5 mV for line voltage variance of 105 VAC to 125 VAC
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA598652010INSULATIONTESTSET 绝缘 试验 组件 PDF

链接地址:http://www.mydoc123.com/p-427190.html