1、INCH-POUND A-A-59716 May 21,2002 COMMERCIAL ITEM DESCRIPTION (CID) STAIRCASE, AIRCRAFT BOARDING CHASSIS MOUNTED, MOTORIZED (MSTA) 1. SCOPE. This document covers a commercial, diesel engine driven, chassis-mounted, aircraft boarding staircase, to be used for passenger loading and unloading. The deck
2、height of the staircase is adjustable to between 96 inches and 228 inches to accommodate B-707, B-727, B-737, B-747, B-757, B-767, B-777, A-300, A-320, A-330, A-340 aircraft, and their military derivatives. 2. SALIENT CHARACTERISTICS. 2.1 General. The aircraft staircase shall be constructed in accor
3、dance with the requirements of SAE ARP 1247, “General Requirements for Aerospace Ground Support Equipment, Motorized and Nonmotorized,” SAE ARP 836, “Design and Safety Criteria for Passenger Boarding Stairways,” and this document. In the event of a conflict between either ARP 1247 or ARP 836 and the
4、 text of this document, this document shall take precedence. Nothing in this document, however, supercedes applicable laws and regulations, unless specific exception has been obtained by the procuring agency. 2.1.1 Standard Commercial Product. The aircraft staircase, as a minimum, shall be in accord
5、ance with the requirements specified herein and shall be the manufacturers standard commercial product. Additional or better features which are not specifically prohibited by the specification, but which are part of the manufacturers standard product, shall be included in the unit being furnished. A
6、 standard commercial product is a product that has been sold or currently offered for sale on the commercial market through advertisements, manufacturers catalogs or brochures, and represents the latest production model. The aircraft staircase shall have been previously accepted by demonstrated sati
7、sfactory performance of boarding passengers in commercial and/or USAF Military Aircraft. 2.1.2 The aircraft staircase shall be operable by a single person. It shall be maintainable with standard tools and built with parts from commercial sources. Beneficial comments, recommendations, additions, dele
8、tions, clarifications, etc. and any data that may improve this document should be sent to: 295 Byron Street, WR-ALC/LESVS Robins AFB, GA 31098-1611 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. AMSC N/A FSC 1730 Provided by IHSNot for ResaleNo reproduction or netw
9、orking permitted without license from IHS-,-,-A-A-59716 2 2.2 Components. The chassis-mounted aircraft staircase shall consist of the following major components: Item or System Name See Characteristic Chassis 2.5 Frame 2.6 Height adjustment system 2.7 Lighting System 2.8 2.3 Design and Construction.
10、 The staircase unit shall be built to withstand the strains, jars, vibrations, and other conditions incident to shipping, storage, and service. It shall be so designed and constructed that no parts work loose in service. 2.3.1 Maintainability. The staircase unit shall be designed and constructed as
11、specified herein and shall comply with the following: a. There shall be a minimum number of parts consistent with reliability and performance specified herein. b. The staircase unit shall allow adjustments, servicing, maintenance, and replacement of parts and components with minimum disturbance to o
12、ther equipment, parts or components. Parts and components shall be positioned for access and ample working space shall be provided, unless performance or reliability is appreciably degraded by the access location. In performing maintenance, if engineering reasoning or data determines that physical o
13、r visual interference between items cannot be avoided, the item predicted to require the most maintenance shall be provided primary access. c. Routine maintenance shall be performable with common tools and equipment available commercially. Special purpose tools and equipment shall be identified. Pro
14、vision of special purpose tools and equipment shall be subject to approval by the procuring agency. d. A minimum number of tools shall be required for maintenance by design practices, such as reducing the variety of bolt head sizes. 2.3.2 Access to Passenger Entrance. The staircase shall be designed
15、 to provide a safe means of access to the passenger entrance of the aircraft. The top platform shall be adjustable to all heights above ground level within the range of 96 inches to 228 inches. 2.3.3 Ramp aircraft mating. The ramp adjustment provisions shall be designed so that the staircase top pla
16、tform shall mate with the aircraft passenger door opening at any height within the required operating range without forming a step or gap of more than two (2) inches between the doorsill of the aircraft and the top platform. The platform side panels shall not strike the side of the aircraft serviced
17、 by this staircase or form a gap between each side panel and the aircraft of more than three (3) inches when adjusted for the aircraft being serviced. The side panels shall lock in position with positive-type lock and hands-free operation. Provided by IHSNot for ResaleNo reproduction or networking p
18、ermitted without license from IHS-,-,-A-A-59716 3 2.3.3.1 Top platform side panel rollers. If rollers are utilized on the top platform side panels, the rollers shall be configured to conform to the shape of the track on which they operate and shall be of sufficient depth to prevent the rollers from
19、coming off the track. 2.3.4 Wiring. The electrical wiring system shall be of a standard commercial, outdoor, weatherproof construction including wire, junction boxes, fixtures, and wired receptacles in accordance with ARP 1247. All 110V circuits shall be in accordance with NFPA 70. The wire shall be
20、 of adequate rating for the power load imposed and shall be securely mounted throughout the staircase. 2.3.5 Lifting system The staircase shall be provided with means to enable the stairway to be lifted from the chassis. If lifting eyes are used the inside diameter of each lifting eye shall not be l
21、ess than two (2) inches. A minimum safety factor of 3:1 shall be applicable for the lifting system, based on the weight of the staircase unit. 2.3.6 Drainage provisions. The staircase shall include provisions for the continuous drainage of water from the steps, platform, structural members, and othe
22、r components. 2.3.7 Air transportability. The completely assembled staircase shall be air transportable in a type C-5 and C-17 cargo aircraft. MIL-HDBK-1791 and MIL-STD-1366 shall be used as references. Additional information will be provided by the procuring agency upon request. 2.3.7.1 Restraints.
23、 Aircraft cargo compartment restraint instructions shall be furnished. Restraint provisions must be marked with capacities and in sufficient number and location to restrain the unit to the requirements of MIL-HDBK-1791, i.e., 3G forward, 2G vertical (up) and 1.5G aft and lateral. In addition, all st
24、ored or installed equipment must meet these same requirements and all components must be capable of withstanding a vertical (down) load of 4.5G. 2.3.7.2 Ground clearance. The staircase shall have a minimum ground clearance of six (6) inches. 2.4 Performance. The staircase shall withstand the followi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA597162002STAIRCASEAIRCRAFTBOARDINGCHASSISMOUNTEDMOTORIZEDMSTA 装有 航空器 拼板 底架 机动 楼梯 MSTAPDF

链接地址:http://www.mydoc123.com/p-427146.html